Knowde Enhanced TDS
Identification & Functionality
- Product Type
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
- Product Features
Chemical Resistance:
- Chem-Screen Topcoat is highly resistant to most common acids, bases and solvents.
- It is the product of choice when the material needs to resist acid and caustic solutions.
Durable:
- Chem-Screen Topcoat will satisfy most industrial demands for a long-wearing, attractive finish.
- This product has excellent abrasion resistance and is ideal for industrial applications where chemical resistance is a concern.
VOC Compliant:
- Chem-Screen Topcoat has nearly zero pounds of solvent per gallon.
- It can be sold anywhere in the country because it applies to all VOC regulations.
Applications & Uses
- Markets
- Surface Preparation
- The most suitable preparation would be a fine brush blast (shot blast) to remove all debris.
- All dirt, foreign contaminants and oil must be removed to assure a trouble-free bond to the substrate.
- Test the surface to make sure concrete is dry by placing a 4" x 4" (1.22 m x 1.22 m) plastic sheet on the substrate and taping down the edges.
- After 24 hours, if the substrate under the plastic is still dry, then the substrate is dry enough to start coating.
- The plastic sheet test is also a good way to determine if hydrostatic pressure problems exist that may later cause disbonding.
- Product Mixing
- Standard packages are in pre-measured kits and should be mixed as supplied in the kit.
- We do not recommend breaking kits down unless suitable weighing equipment or a graduated bucket is available.
- After the two parts are combined, mix well with slow-speed mixing equipment such as a jiffy mixer until the material is thoroughly mixed and streak-free.
- After mixing, transfer the mixed material to another pail (the transfer pail) and remix it again.
- The material in the transfer pail is now ready to be applied on the primed substrate.
- Improper mixing may result in product failure.
- Priming
- A suitable primer should be used before applying this product.
- Without primer, porous substrates may cause outgassing and possible surface defects.
- Product Application
- The mixed material can be applied by brush, roller or spray.
- Or use a serrated squeegee and then backroll as long as the appropriate thickness recommendations are maintained.
- Maintain temperature and relative humidity within the recommended ranges during the application and curing process.
- If concrete conditions or over-aggressive mixing causes air entrapment, then an air release roller tool should be used.
- This product can be used with colored sand in a broadcast system.
- Other suitable aggregates can also be used to achieve a variety of colors and patterns.
- Re-coat or Topcoating
- If you opt to re-coat or topcoat this product, be sure that the coating has tacked off before recoating.
- Colder temperatures will require more cure time.
- Before re-coating or top-coating, check the coating to insure no epoxy blushes (a whitish, greasy film or deglossing) have developed.
- If a blush is present it must be removed with a standard detergent cleaner.
- Multiple coats of this product are compatible.
- Floor Cleaning
- Some cleaners may affect the color of the floor installed.
- Test each cleaner in a small area, utilizing your cleaning technique beore cleaning the entire surface.
Properties
- Color
- Technical Data
- Curing Schedule*
* Time varies depending on air temperature and humidity.
Value | Units | Test Method / Conditions | |
Flexural Strength | 10120.0 | psi | ASTM D 790 |
Tensile Strength | 6550.0 | psi | ASTM D 638 |
Hardness | 82.0 | Shore D | - |
Non-Volatile Content by Weight | 97.0 | % | - |
Non-Volatile Content by Volume | 96.0 | % | - |
Clean Up | Using Xylol | - | - |
Film Thickness | 16 - 18 | mils | - |
Coverage Rate | 90 - 100 | ft2/gal | - |
Curing Schedule* (Pot Life, 1.5 gal., 70°F) | 30 - 40 | minutes | - |
Curing Schedule* (Tack Free, 70°F) | 8 - 12 | hours | - |
Curing Schedule* (Recoat/Topcoat, 70°F) | 14 - 16 | hours | - |
Curing Schedule* (Light Foot Traffic, 70°F) | 24.0 | hours | - |
Curing Schedule* (Full Cure, 70°F) | 2 - 7 | days | - |
Safety & Health
- Precautions
- Use with adequate ventilation
- Avoid contact with eyes, skin and clothing, wear gloves or protective creams - if skin contact occurs, wash at the first opportunity with soap and water
- Eye exposure or inhalation can result in serious medical problems - in the event of eye contact, immediately flush eyes with water and contact a physician
- Keep out of the reach of children
- For industrial use only
Packaging & Availability
- Packaging (Kit)
- 1 gallon (3.7 L)
- 5 gallon (18.5 L)
Storage & Handling
- Shelf Life
- 1 year (Unopened)
- Product Storage
- Continuous storage should be between 60 - 90 °F (15 - 32 °C).
- Low temperatures or extreme temperature fluctuations may cause crystallization.
- Before use, bring the product to room temperature.