GEHR POM® 10 PE (GLIDE) are used for tribological applications in which increased sliding wear is to be expected, POM-10PE is frequently used, whose sliding properties have been significantly enhanced. This type of POM-C with modified sliding properties also has a raw material food contact approval.

Polymer Name: Polyacetal Copolymer (POM)

Physical Form: Custom, Rods, Sheets

Features: Dimensional Stability, Electrically Insulating, Food Contact Acceptable, Good Environmental Stress Crack Resistance (ESCR), Good Sliding Properties, Good Solvent Resistance, Good Thermal Stability, High Rigidity, High Stiffness, High Strength, Low Water Absorption, Tribological Modified

Density: 1300.0 - 1360.0 kg/m³

Color: Blue

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Technologies

Features & Benefits

Properties
  • Pressure tested quality
  • High strength and stiffness
  • High rigidity (to -40 °C)
  • High thermal stability
  • Low water absorption
  • High dimension stability
  • Good electrical insulating properties
  • Very good sliding properties
  • High resistance to solvents
  • Very high resistance to stress cracks

Applications & Uses

Plastics & Elastomers End Uses
Plastics & Elastomers Processing Methods
Applications
  • Sliding bearings
  • Cutting boards
  • Valve parts

Properties

Color
Flame Rating
Physical Form
Form and Condition
Rods. Sheets / Solid
Odor
Odorless
Insoluble in
Water
Mechanical Properties
ValueUnitsTest Method / Conditions
Tensile Strength at Yield44MPaISO 527
Elongation at Yield (S)9%ISO 527
Elongation at Break (R)10%ISO 527
Impact Strength (an)30kJ/m2ISO 179
Notch impact Strength (ak)4kJ/m2ISO 179
Hardness79Shore DISO 868
Modulus of elasticity (Et)2160MPaISO 527
Physical Properties
ValueUnitsTest Method / Conditions
Specific Gravity1.34ISO 1183
Water Absorption0.8%ISO 62
Humidity Absorption0.2%ISO 62
Maximum Permissible Service Temperature100°CUL746B
Lower Permissible Service Temperature-40°CUL746B
Thermal Properties
ValueUnitsTest Method / Conditions
Heat Deflection Temperature (HDT/A)120°CISO 75
Coefficient of Linear Thermal Expansion1.2K-1.10-4ISO 11359
Thermal Conductivity (20°C)0.3W/(m.K)ISO 22007-4
Glass Transition Temperature (Tg)-60°CISO 3146
Melting Temperature (Tm)164°CISO 3146
Typical Properties
ValueUnitsTest Method / Conditions
Density1.30 - 1.36g/cm³
Melting Temperature163 - 168°C
Thermal Decompositionmin. 240°C
Ignition Temperature320 - 340°C
Electrical Properties
ValueUnitsTest Method / Conditions
Volume Resistivitymin. 10^13Ω.cmIEC 60093
Surface Resistivity (Ro)min. 10^13ΩIEC 60093
Dielectric Constant (1MHz)4.4-IEC 60250
Dielectric Loss Factor (1 MHz)3-IEC 60250
Dielectric Strength35kV/mmIEC 60243-1
Tracking ResistanceCTI 600VIEC 60112
Additional Information
ValueUnitsTest Method / Conditions
Physiological Indifference (FDA)Yes-
FlammabilityHB-UL 94

Regulatory & Compliance

Certifications & Compliance

Technical Details & Test Data

Fire-fighting Measures

Suitable extinguishing agents

Water, foam, dry chemical, carbon dioxide (CO2).

Potential combustion products

Carbon dioxide (CO2), carbon monoxide (CO). Formation of further decomposition and oxidation products depend upon the fire conditions. Under special fire conditions traces of other toxic substances are possible.

Special protective equipment

Wear a self-contained breathing apparatus. If exposed to combustion fumes bring the victim into fresh air.

Further information

Dispose of fire debris and contaminated extinguishing water in accordance with official regulations..

Safety & Health

Safety Measures

The general industrial safety measures should be considered. A thermal damage during machining should be avoided.

Storage & Handling

Machining

The product can be machined with standard machinery and tools. Before machining the product should be stored at room temperature 24 h. Evacuate swarf to prevent slipping or tripping. Observe the maximum allowable concentration of dust and formaldehyd levels on the working area which apply in your country. Wear safety goggles during machining. General dust limit value: Respirable dust (6 mg/m3); Inhalable dust (10 mg/m3 ).

Storage

The products shall be stored indoor to keep away from any source of degradation such as sunlight, UV-jets, ionizing radiation, chemicals.