company tower banner
Gillespie Coatings Company Logo

Gillespie Coatings PR-33-112 Gray

PR-33-112 Gray is a phenolic modified alkyd primer with excellent sprayability.

Product Type: 1K (1 component) Coating, Primer

Compatible Substrates & Surfaces: Metal

Features: Corrosion Resistant, Moisture Resistant

Application Method: Spray

Chemical Family: Alkyds

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Chemical Family

Features & Benefits

Ready-to-Use Product Features
Characteristics
  • Premium quality universal primer
  • VOC and HAPs compliant coating
  • Resists corrosion
  • Single stage component
  • Superior lift resistance
  • Contains no lead or chromate pigments

Applications & Uses

Application Method
Compatible Substrates & Surfaces
Typical Uses
  • Qualified for continuous standard mineral oil immersion
  • For use in industrial, structural and transportation applications.
  • For use in fabrication\
  • For use on interior or exterior metal surfaces
  • Has superior resistance to moisture or fumes
  • Temperature is limited to 250°F
  • Not for severe service in environments such as acids or base
Limitations
  • Limitations for severe chemical acid or base.
  • PR 33 Series primers are acceptable with a minimum 24-hour dry time when immersed in standard mineral oils. The GCI first recommended cure time remains a safe 3-day period. This would accommodate ambient and seasonal temperature variations.
Application

Surface Preparation

  • SSPC: SSP1 – solvent cleaning
  • SSPC: SSP2 – hand tool cleaning
  • SSPC: SSP6 to achieve 1.5 to 2.0 mils anchor profile (*) as determined with a Keane-Tator Surface Profile Comparator, Testex Tape or similar device.
  • Remove abrasive residue and dust from surface. Remove weld splatter, round off rough welds and sharp edges. The surface must be clean and free from oil, moisture, grease, dust, mill scale, and rust.

Mixing

Paint must be thoroughly mixed to a uniform consistency with a low-speed air-powered or explosion-proof power agitator.


Application Equipment

  • Application Equipment - The following is a guide suitable for equipment from various manufacturers. For proper spray characteristics, changes in pressure and type size may be needed.
    • Airless pump ratio - 30:1
    • Non-cycling, air pressure to pump, approximately - 40 - 50 psi
    • Tip pressure is approximately 1200 psi.
    • Tip size - .015-inch to .017-inch
  • Conventional Spray - The following is a guide suitable for equipment from various manufacturers. For proper spray characteristics, changes in pressure and type size may be needed. Mainline air supply with moisture and oil trap is recommended.
    • Main air-line pressure - 100 psi
    • Fluid (pot) pressure - 60 - 65 psi
    • Atomizing (gun) - 40 - 70 psi
    • Tip size - .046-inch to .070-inch

Film Thickness

  Minimum Maximum
Wet Mils 3.5 mils 5 mils
DFT Mils 1.5 mils 2.5 mils

Recommended Thinning

  • Conventional equipment under normal conditions uses GCI ES-5 (xylene). In high ambient temperatures, use GCI ES-2.

Application conditions

Optimum application temperatures are at temperatures above 50°F (painting in direct sunlight is not recommended in hot weather) and surface temperatures must be at least 5°F above the dew point to avoid condensation formation. Do not apply when humidity is high and condensation is possible.


Average Drying time

  • To Touch - 10 - 15 Minutes
  • Tack Free - 30 Minutes
  • Through dry - 8 Hours
  • Re-coat - 30 - 60 Minutes for alkyds, 6 months max.

Dry times are affected by air and surface temperatures, relative humidity ventilation and film thickness.


Clean-Up Solvent

  • GCI ES - 5 (xylene)
  • GCI ES - 19 (MEK)
  • Clean equipment immediately after use.
  • All surplus materials and empty containers should be disposed of according to regional regulations.

Recommended Topcoats

Enamels 

  • GCI Alkyd Enamel Series: 11, 25, 41, 44, 55, 75
  • Intermediate service, top coat with epoxy or polyurethane enamel
  • GCI 244 Compliant Series alkyd

Properties

Color
Physical Properties
ValueUnitsTest Method / Conditions
Gloss (60° Gloss Meter)10 - 20°
VehiclePhenolic Modified Alkyd
Pigment TypeRust Inhibiting Zinc Phosphate and Modified Zinc Phosphate.
Solvent TypeAromatic Blend, Xylene, Tertiary Butyl Acetate
VOC3.2 - 3.4lbs/gal
Weight (Varies With Color)10.5 - 10.9lbs/gal
Flash Point88.0°F
Recommended Dry Film Thickness1.5 - 2.5mils
Theoretical Spread Rate (At 1 dry mil)610 - 642ft²
Volume Solids38 - 40%
Viscosity (78°F)60 - 70Ku

Technical Details & Test Data

Resistance

Resistant to general service protection on metal surfaces, superior moisture resistance for alkyd system, dry heat to 250°F.

Packaging & Availability

Packaging Type
Packaging

55 gallon size drum

Storage & Handling

Shipping Data
  • DOT Name - Paint
  • UN Number - UN1263
  • Hazardous Class - 3, Flammable Liquid
  • Packing Group - PG III