Tique Aquaguard

1 of 8 products in this brand
Tique Aqua Guard is a one component, fluid-applied vapor permeable air/ water-resistive barrier. It is applied directly to vertical, above-grade approved wall substrates and provides an excellent waterproof air barrier when combined with Tique Wall Systems joint and rough opening treatment.

Product Type: 1K (1 component) Coating

Features: High Gas Permeability, Low VOC, Non-Toxic

Compatible Substrates & Surfaces: Concrete, Masonry, Wood

Application Method: Roller, Spray

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Features & Benefits

Ready-to-Use Product Features
Features
  • Waterproof
  • Vapor Permeable
  • Structural with wind
  • Resists UV Degradation/ Added Durability
  • Low VOC formulation
Benefits
  • Possible water damage minimized with repair and restoration costs associated
  • Condensation risk in wall minimized from water vapor diffusion
  • No air leakage between sheathing and Tique Wall Systems WRB; rigid/stable under air pressure loads; does not tear or blow off the wall
  • 180 day exposure rating during construction.
  • Safe, non-toxic; VOC compliant

Applications & Uses

Application Method
Compatible Substrates & Surfaces
Surface Preparation

Substrate shall be dry, clean, sound and free of release agents, paint or other residue or coatings. Damaged sheathing must be removed and replaced.

Avoid application over irregular surfaces.

Substrate to be coated must be continuous without joints, holes, etc. exceeding 1/32" (0.8 mm) in size. Sheathing must be properly installed as required by applicable building codes or sheathing manufacturer.

Mixing

Mix with a clean, rust-free electric drill and paddle until thoroughly blended.

Dilution of tique wall systems liquid weather resistive barrier is not recommended.

Application

Clean, dry, properly prepared, frost-free surfaces are needed for application. Tique Wall Systems joint and rough opening treatment required for sheathing joints, inside and outside. Spot fasteners, knots or other voids in sheathing surface. Pre-spot all fasteners with Tique Wall Systems Aqua Guard if using Tique Wall Systems Sheathing Fabric including all other voids and spot surface defects such as overdriven fasteners, knots and voids.

Gypsum Sheathing, Glass-Mat Gypsum Sheathing, Exterior Plywood / Exterior - Apply Tique Wall Systems Aqua Guard to prepared substrate using spray equipment that can support a minimum 1 Gallon per minute (GPM) and a .031 mil tip at 3000+ psi., or with the appropriate size nap roller in a single, uniform coating at a wet thickness of 10 mils. Application over Glass-Mat Gypsum Sheathing, plywood and exterior gypsum sheathing: use a 1/2" (13 mm) nap roller.

Oriented Strand Board (OSB) - A two-coat application of Tique Wall Systems Aqua Guard is required over OSB. The first coat is applied over the prepared substrate prior to treating sheathing joints, rough openings, and corners. Apply Tique Wall Systems Aqua Guard by spray or roller with a 1/2" (13mm) nap roller in a single, uniform coating at a wet thickness of 10 mils and allow drying. For air barrier, sheathing joints, rough openings, and corners must then be covered with Tique Wall Systems joint treatment. Substrate to receive the second coat of Tique Wall Systems Aqua Guard must be continuous without joints, holes, etc. exceeding 1/32" (0.8 mm) in size. The second coat of Tique Wall Systems Aqua Guard must be applied over the treated surface in a single, uniform coating to a wet thickness of 10 mils.

Concrete Masonry Wall Construction - Concrete masonry wall construction must be structurally sound, clean, dry, and free from damage, frost, and all bond-inhibiting material, including dust, dirt, mold, algae, and efflorescence. Repair cracks up to 1/8 inch (3 mm) wide by filling. Rake the crack with a sharp tool to remove loose or friable material, and blow clean with oil-free compressed air. For cracks wider than 1/8" (3 mm) and up to 1/4" (6 mm) wide, use a paintable acrylic latex caulk to fill the crack, tool flush with the surface, and allow drying completely. For moving cracks consult a structural engineer. Protect crack repair materials from rain and freezing until dry.

Air and Moisture Barrier

Spray-applied over CMU - Apply Tique Wall Systems Aqua Guard uniformly with suitable spray equipment. Backroll to fill the surface and allow drying. Apply a second uniform coat of Tique Wall Systems Aqua Guard and back-roll to achieve void / pinhole free surface. Depending on the condition of the surface, a minimum of 10 wet mils up to a maximum of 30 wet mils per coat is required. Apply additional coats if needed to achieve a void / pinhole free surface.

Roller-applied over CMU - Apply Tique Wall Systems Aqua Guard uniformly with a 3/4 inch (19 mm) nap roller and allow drying. Apply a second uniform coat of Tique Wall Systems Aqua Guard to achieve a void and pinhole free surface. Depending on the condition of the surface a minimum of 10 wet mils up to a maximum of 30 wet mils per coat is required. Apply additional coats if needed to achieve a void and pinhole free surface.

Important Note - Tique Wall Systems Aqua Guard functions as a waterproof air barrier on normal weight concrete masonry unit wall construction with flush (struck flush with the surface of the CMU) or concave joints when a minimum of two liberal coats are applied. Additional coats may be necessary depending on the condition of the CMU wall surface, CMU porosity, joint profile, and other variables that may exist. For ”rough” CMU wall surfaces, skim coat the entire surface with Tique Wall Systems cementitious leveler before application of Tique Wall Systems Aqua Guard. A void and pinhole free surface must be achieved for Tique Wall Systems Aqua Guard to properly function as a waterproof air barrier on CMU wall surfaces.

Curing/Drying - Tique Wall Systems Aqua Guard is dry to touch and can be over coated within 2-4 hours under normal conditions [70ºF (21ºC), 50% RH]. Wait 24 hours before adhesive attachment of Tique Wall Systems insulation board. Final drying varies depending on temperature / humidity and surface conditions. Protect from rain and freezing until completely dry.

Material Storage - Keep containers covered to protect from skinning. If skin forms, remove the skinned material from container; remaining material is unaffected by skinned material.

Clean Up - Clean tools and equipment with water immediately after use. Dried material can only be removed mechanically.

Coverages per Pail
  • Glass-Mat Gypsum Sheathing - 420-520 ft² (39-48.3 m²)
  • Exterior Gypsum - 420-520ft² (39-48.3m²)
  • Cement Board - 450-600 ft² (41.8-55.7 m²)
  • Poured Concrete - 450-600 ft² (41.8-55.7m²)
  • Plywood* - 135-175 ft² (12.5-16.3m²)
  • OSB* - 135-175ft² (12.5-16.3 m²)
  • CMU Standard Weight* - 225-275 ft² (20.5-25.5 m²)

*Coverage for C-1177 sheathing, cement board, poured concrete is at 10 mils WFT; for Plywood, OSB and CMU are at 20 mils WFT.

When used with Tique Wall Systems Sheathing Joint Tape to treat the sheathing joints and rough openings: (coverage may vary based on condition).

  • 0'-4" Sheathing Fabric 625 ft (190.5m) / pail
  • 0'-6" Sheathing Fabric 425 ft (129.5m) / pail
  • 0'-9" Sheathing Fabric 285 ft (87m) / pail
Limitations
  •  Apply only when the surface and ambient temperatures are above 40°F (4°C) and below 100ºF (38ºC) during application and drying period.
  • Not recommended for use when cool, damp conditions exist for prolonged periods. Cool, damp conditions retard drying and may require extended periods of protection.
  • Do not use on damp surfaces, below grade, or on surfaces subject to water immersion.
  • Not recommended for use over fire-retardant treated or pressure treated plywood substrates.
  • Not recommended for spanning sheathing joints or holes in excess of 1/8" (3 mm) wide.
  • Contact Tique Wall Systems Technical Service for additional information regarding coverage over different brands.
  • Ventilate temporary heaters to the exterior to prevent water vapor from accumulating on or within the wall assembly materials.
  • Tique Wall Systems Aqua Guard can be left exposed to weather for up to 6 months of installation to protect the substrate.
  • When Tique Wall Systems Aqua Guard is used in conjunction with Tique Wall Systems Continuous Insulation Systems ensure the Tique Wall Systems Aqua Guard surface is clean, dry, and free of surface contamination. Install Tique Wall Systems Continuous Insulation System Board within 30 days of the application of Tique Wall Systems Aqua Guard, or clean the surface and recoat with Tique Wall Systems Aqua Guard.
  • For Portland cement stucco and similarly constructed wall assemblies over metal lath contact Tique Wall Systems Technical Service.

Properties

Technical Data
ValueUnitsTest Method / Conditions
Air Leakage0.02L/Min./m²ASTM E283
Air Permeance (75Pa)max. 0.02L/s/m²ASTM E2178-11
Flame PropogationPass; UL CertifiedNFPA-285
Puncture Resistance31.5lbsLab Test
Racking (No cracking, Net Deflection 1/8")PassASTM E72
Radiant Heat lgnition (No Flame Spread/Ignition)PassNFPA-268
Solids (By Volume, Calculated)65.0%
Structural Performance (10 Cycles)PassASTM E1233 Proc A
Tensile BondPassASTM C-297
Tensile BondPassASTM E2134
Tensile Bond (Liquid Weather Barrier Flashing, min 15 psi)min. 70psiASTM C297/297M-04(2010)
Tensile Bond (Substrate, min 15 psi)min. 20psiASTM E2568-09e1
Transverse Load (10 Cycles)PassASTM E1233 AC-212
Volatile Organic Compoundsmax. 3g/l
Water Penetration (15 min, 2.86psf)PassASTM E331
Water Resistance (14 Days Exposure)PassASTM D2247-11
Water Resistance (14 Days Exposure)PassASTM E2568-09e1
Water Vapor Transmission (Vapor Permeable)PassASTM D2247-11
Water Vapor Transmission (Vapor Permeable)PassASTM E2570

Regulatory & Compliance

Compliance

This product complies with US EPA, South Coast AQMD and Greenseal Standard VOC emission standards for architectural coatings.

Safety & Health

Health & Safety

Health Precaution - As with any chemical construction product, exercise care when handling.

  • Warning - Causes eye and skin irritation.

Safety Precaution - Wash hands thoroughly after handling. Wear protective gloves/protective clothing/eye protection/face protection.

First Aid

  • Eye Contact - Immediately flush eyes with plenty of water for at least 15 to 20 minutes. Ensure adequate flushing of the eyes by separating the eye lids with fingers. Get immediate medical attention.
  • Skin Contact - Immediately wash skin with plenty of soap and water for at least 15 to 20 minutes, while removing contaminated clothing and shoes. Get medical attention if irritation develops or persists.
  • Inhalation - If inhaled, remove to fresh air. If not breathing give artificial respiration or give oxygen by trained personnel. Seek medical attention immediately.
  • Ingestion - If swallowed, do not induce vomiting. Call a physician or a poison control center immediately. Never give anything by mouth to an unconscious person.

Spills - Contain and collect in an appropriate container. Uncured material may be removed with water.

Disposal - Dispose of in accordance with local, state or federal regulations.

Warning - Keep container closed when not in use. Keep out of the reach of children. Not for internal consumption. For industrial use only.

Packaging & Availability

Availability

Available with or without aggregate.

Packaging

5 gallon (19L) 52.5 lbs / 23.8 kg per pail

Storage & Handling

Shelf Life

24 months, if properly stored and sealed.

Storage

Store Aqua Guard in a cool, dry place protected from freezing. Store at no less than 4°C (40°F). Protect from extreme heat and direct sunlight.