company tower banner
Greenmaker Industries Company Logo

Tique Groundcoat

1 of 8 products in this brand
Tique Ground Coat is an elastomeric weather resistive air barrier, adhesive and base coat combined with Portland Cement. Tique Ground Coat is used in the Tique Continuous Insulation Systems, as well as in the direct applied application on vertical wall assemblies. It is a two component product.

Product Type: 2K (2 component) Adhesive, 2K (2 component) Coating, Base Coat, Elastomeric Coating

Compatible Substrates & Surfaces: Concrete, Expanded Polystyrene (EPS), Masonry, Plastics

Features: Breathable, Crack Resistant, Excellent Productivity, Good Flexural Modulus, Good Weather Stability, High Air Permeability, Low VOC

Application Method: Roller, Spray, Trowel

Chemical Family: Acrylics & Acrylates

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Chemical Family

Features & Benefits

Features
  • 100% Acrylic Polymer-modified
  • Smooth consistency
  • Vapor permeable
  • Low VOC
Benefits
  • Flexural strength, resists cracking, increased finish coverage.
  • Trowels on easily; increases productivity.
  • Allows substrate to breathe naturally; resists blistering due to vapor.
  • Safe for workers and the environment.

Applications & Uses

Application Method
Surface Preparation

As a Weather Resistive Barrier / Base Coat / Adhesive

Insulation Board - Insulation must be rasped and free of all bond inhibiting materials.

Approved Substrate - Surfaces must be clean, dry and free of frost, damage and all bond inhibiting materials, including dirt, efflorescence, laitance, form oil and other foreign matter. Loose or damaged material must be removed by water blasting, sandblasting or mechanical wire brushing and repaired.

Apply Tique Deco-Prep to approved substrate by roller or spray as per Tique Details.

Application

Apply only to sound and clean, dry, properly prepared, frost-free surfaces.

As a Weather Resistive Barrier / Base Coat - Apply with a stainless steel trowel to an approximate thickness of 1/8" (3 mm). Work horizontally or vertically in strips of 40” (1 m) and immediately embed Tique Reinforcing Mesh in wet base coat by troweling from the center to the edges of the mesh. Avoid wrinkles in the mesh and smooth the base coat to eliminate trowel marks. Minimum recommended dry thickness of the reinforced base coat is 1/16" (1.6 mm) when dry. Reapply additional base coat if necessary to achieve minimum thickness as soon as the first application is dry. Embedded mesh in base coat should not be visible.

Crack Repair - Embed Tique Reinforcing Mesh centered over the crack in Tique Reinforcing Mesh and feather along edges.

As a High Build Coat - Apply with a stainless steel trowel to a maximum thickness of 3/8" to the prepared surface.

Curing/Drying - Dries within 24 hours under normal drying conditions [70ºF (21ºC), 50% RH]. Allow additional drying time during cold, humid, or wet weather until insulation board is fully adhered before rasping, and before application of primer or finish to hardened Base Coat. Protect from rain, freezing and continuous high humidity until completely dry. Tique recommends using Tique Primer prior to application of finish.

Clean Up - Clean tools and equipment with water immediately after use. Dried material can only be removed mechanically.

Coverage

As an Adhesive / Base Coat - Coverage will vary based on substrate and substrate condition.

Embedding Coat - 250 ft² (23.2 m²) 1/16” thickness

Weather Resistive Barrier / Base Coat - 250 ft² (23.2 m²) per pail 1/16” thickness

Coverages may vary depending on adhesive / basecoat application technique and surface conditions.

Mixing

Mix equal parts of Tique Ground Coat to Type 1 Portland cement by weight. Mix with a clean, rustfree electric drill and paddle. Allow to set approximately five minutes, adjust mix if necessary by adding up to 8 fl. oz. (0.24 L) of water, (adjusting for trowelability) and remix to a uniform consistency. Avoid re-tempering after mixing of product.

Limitations
  • Use Tique Ground Coat only when surface and ambient temperatures are above 40°F (4°C) and below 100°F (38°C) during application and drying period.
  • Sloped surfaces: Refer to Tique details.
  • Tique Ground Coat used on weather-exposed horizontal: Contact Tique Technical Service.
  • Ground Coat should not be used as a finish coating.

Properties

Physical Form
Technical Data
ValueUnitsTest Method / Conditions
Accelerated Weathering (2000 hours)PassASTM G-23
Adhesion (Concrete Block, 28 days)min. 90psiASTM C-297
Adhesion (Concrete, 28 days)min. 50psiASTM C-297
Adhesion (Dens-Glass® Gold, 28 days)min. 30psiASTM C-297
Adhesion (EPS Board, 28 days)min. 13psiASTM C-297
Adhesion (Gypsum Sheathing, 28 days)min. 25psiASTM C-297
Flexural Strength (28 days)65.0psiASTM C-203
Freeze/Thaw Resistance (60 Cycles)Pass, No Deleterious EffectsASTM E-2485
Surface Burning (min. 450 Smoke Developed)PassASTM E-84
Surface Burning (min.25 Flame Spread)PassASTM E-84
Vapor Permeability (Procedure A - Dry)34.47ASTM E-96
Vapor Permeability (Procedure B - Wet)206.83ASTM E-96
Water Absorption (28 days)0.099kg/m²/hrLab Method

Safety & Health

Health & Safety

Health Precaution - Tique Ground Coat is water-based. As with any chemical construction product, exercise care when handling.

  • Warning - Causes eye and skin irritation.

Safety Precaution - Wash hands thoroughly after handling. Wear protective gloves/protective clothing/eye protection/face protection.

First Aid

  • Eye Contact - Immediately flush eyes with plenty of water for at least 15 to 20 minutes. Ensure adequate flushing of the eyes by separating the eye lids with fingers. Get immediate medical attention.
  • Skin Contact - Immediately wash skin with plenty of soap and water for at least 15 to 20 minutes, while removing contaminated clothing and shoes. Get medical attention if irritation develops or persists.
  • Inhalation - If inhaled, remove to fresh air. If not breathing give artificial respiration or give oxygen by trained personnel. Seek medical attention immediately.
  • Ingestion - If swallowed, do not induce vomiting. Call a physician or a poison control center immediately. Never give anything by mouth to an unconscious person.

Spills - Contain and collect in an appropriate container. Uncured material may be removed with water.

Disposal - Dispose of in accordance with local, state or federal regulations.

Warning - Keep container closed when not in use. Keep out of the reach of children. Not for internal consumption. For industrial use only.

Packaging & Availability

Packaging Type
Packaging

5 gal. (19L) pail.

Storage & Handling

Shelf Life

24 months, if unopened, properly stored and protected from moisture.

Storage

Store off the ground in a dry area. Protect from extreme heat [90ºF (32ºC)], moisture and direct sunlight.