company tower banner
GST International Company Logo

GST International Low VOC High Gloss Wet Look Lacquer

Low VOC High Gloss Wet Look Lacquer is a solvent-based, high gloss, crystal clear, deep penetrating barrier coating for decorative concrete, stone, natural and manufactured hardscape surfaces. Low VOC High Gloss Wet Look Lacquer provides a ‘water-wet’ appearance which enhances and beautifies the natural color of the applied surface. Nonyellowing Low VOC High Gloss Wet Look Lacquer seals against food stains, gasoline, grease, oils, water and acid. Its deep bonding formula resists peeling, chipping, cracking and UV degradation.

Product Type: Lacquers, Sealer, Solventborne Coating

Compatible Substrates & Surfaces: Brick, Concrete, Marble, Stone

Features: Acid Resistant, Breathable, Excellent Water Repellency , Fast Drying, Freeze/Thaw Stability, Good Non-Yellowing Properties, Good Penetration, Grease Resistant, High Gloss, Low VOC, Oil Resistant, UV Resistant, Wear Resistant

Application Method: Roller, Spray

Similar Products

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Features & Benefits

Product Highlights
  • Made from the latest developments in VOC compliant solvent-based acrylic chemistry, meeting the strictest national and state requirements.
  • Low VOC High Gloss Wet Look Lacquer delivers excellent resistance to the formation of efflorescence.
  • When used on newly placed concrete, the sealer will help protect against spalling, dusting, freeze-thaw damage and alkali degradation.
  • Low VOC High Gloss Wet Look Lacquer remains hard even under extreme sunlight and delivers superior wear resistance.
  • Its VOC compliant formula works great indoors and outdoors to provide a breathable barrier that allows moisture to escape from the coated surfaces.
  • It is also effective as a joint sand stabilizer for interlocking pavers.
Features
  • max. 100g/l VOC Content
  • Easily applied, fast drying, long lasting
  • Interior and exterior use
  • Inhibits efflorescence
  • Gas, oil and grease resistant
  • Water repellent
  • Non-yellowing and UV resistant
  • 85-90% color densification
Product Characteristics
  • High Gloss
  • Heavy Enhancement
  • Repels Water
  • Repels Grease and Oil
  • Resists Stains
  • Resists Efflorescence
  • Resists Spalling

Applications & Uses

Application Method
Compatible Substrates & Surfaces
Limitations
  • Not recommended for pre-sealed surfaces or non-porous surfaces such as ceramic tile, marble, granite, porcelain and terrazzo.
  • Do not use where hydrostatic pressure is possible.
Use On
  • Standard concrete
  • Colored and stamped concrete
  • Exposed aggregate concrete
  • Natural stone
  • Manufactured stone
  • Interlocking pavers
  • Porous brick
  • Mexican tile
  • Wet Cast concrete products
Coverage
  • Porous Surface: 50 - 200 sq.ft./gal
  • Dense Concrete: 200 - 400 sq.ft./gal
  • For exact coverage rates, a measured quantity to proper saturation over a known area will provide a square foot coverage rate for a specific job.
Clean Up & Remove
  • Clean Up: Lacquer thinner or xylene
  • Remove: Chemical stripper
Surface Preparation
  • Before use on a job, thoroughly test this product on a small area to assure performance and appearance.
  • Use only in well ventilated areas. Immediately remove pools or puddles were over application has occurred.
  • Cleaning your hardscape project with a pressure washer and/or a surface cleaner is the first step in preparing for a successful project.
  • It is strongly recommended to utilize a heated pressure washer to aid in the cleaning process.
  • A heated pressure washer in conjunction with Pro Grade Cleaner will remove most organic stains, weeds, and old polymeric sand in considerably less time than it would take with a cold water unit.
  • A heated pressure washer will also aid in the removal of residual sealer and decrease the labor when ‘stripping’ old sealer off.
  • Stringent cleaners such as muriatic acid can be very harmful to your pavement, causing irreversible damage to the surface.
  • Most colorants for concrete are made from iron oxide (FeO2) or better known as rust.
  • Strong acids like muriatic acid will dissolve these pigments permanently changing the appearance and etching the surface.
  • Allow product to dry thoroughly before applying a sealer.
Application
  • The product is applied with our Low Volume Pump Sprayer.
  • Applying sealer on perimeter edges with a roller is acceptable to eliminate overspray on vegetation and surrounding structures.
  • Using the GST Low Volume Pump Sprayer, add sealer up to the top of the GST Logo printed on the sprayer.
  • Pump the sprayer approximately 30 times to pressurize the tank. Hold the spray wand 8”-10” from the surface and begin to apply the sealer using an overlapping circular motion to ensure an even application.
  • To maintain a consistent even flow of sealer, it will be necessary to continually pump up the sprayer as the pressure in the tank decreases.
  • The surface will appear ‘wet-damp’ for 8-10 seconds.
  • If you over-apply the sealer and create puddles, it will be necessary to stop spraying and disperse additional sealer on the surface with a blower.
  • Back-rolling solvent-based sealers may leave application lines on the surface.
  • On segmental pavement systems, application of any sealer with a roller is not recommended as it will pull sand from the joint and will deposit it on the surface causing an undesirable result.
  • One coat will seal, protect and enhance the beauty of the surface.
  • If a second coat is necessary due to extreme porosity, apply as soon as the first coat is dry to the touch.
  • GST sprayers are made with solvent resistant tips and seals, however do not let the sealer dry on the spray tip.
  • If this occurs, soak the tip in lacquer thinner. Replacement tips are available.
  • Do not apply the product during inclement weather or in direct sunlight when temperatures exceed 80ºF.
  • Application to a damp surface or uncured concrete (28 day minimum) may cause a hazy appearance or loss of adhesion.
  • Air and surface temperature should be between 50ºF and 80ºF for 24 hours following application.
Use With
  • Indoor applications
  • Outdoor applications
  • Porous Surfaces
  • Dense Surfaces
  • Concrete, Exposed Aggregate
  • Pavers and Slabs
  • Brick Masonry
  • Natural Stone & Travertine

Properties

Appearance
Clear
Odor
Medium
Typical Properties
ValueUnitsTest Method / Conditions
VOCmax. 100g/l-
Flash Point-4.0°F-
Weight Per Gallon7.1Ibs./gal-
Package Viscosity (Zahn Cup #2)19.0seconds-
Solids by Volume20.0%-
Dry Time10 - 30minutes-
Cure Time24 - 48hours-
Rainproof24.0hours-

Regulatory & Compliance

HMIS Ratings

H - 2; F - 3; R - 0; PP - H

Compliance
  • Meets or exceeds Federal EPA standards for VOC compliance.
  • Meets or exceeds South Coast Air Quality Management District and the Bay Area Air Quality Management District, for VOC compliance of less than 100g/l required by the State of California.

Technical Details & Test Data

Water Penetration Test
  • Drop a small amount of water on the sealed surface.
  • If water penetration occurs or if water does not bead up on the surface, the application of additional sealer is required.

Safety & Health

Safety
  • Excessive inhalation of vapors can be harmful. Intentional misuse by deliberately concentrating and inhaling the contents may be harmful or fatal.
  • Reports have associated repeated and prolonged occupational overexposure to solvents with permanent brain and nervous system damage.

If on Skin (or Hair):

  • Wash with soap and water.

If Inhaled:

  • Excessive inhalation of vapors can be harmful.
  • Remove person to fresh air and keep comfortable for breathing.

If in Eyes:

  • Cause serious eye irritation.
  • Immediately flush with plenty of water for at least 15 minutes.
  • After initial flushing, remove any contact lenses and continue for at least 15 minutes.

If Ingested:

  • May be harmful if swallowed.
  • Do not induce vomiting, see a physician.
  • Do not handle until all safety precautions have been read and understood.
  • Keep away from heat, hot surfaces, sparks, open flames, and other ignition sources.
  • No smoking. Ground/bond container and receiving equipment.
  • Use explosion-proof electrical ventilating/lighting equipment.
  • Use only non-sparking tools. Take precautionary measures against static discharge.
  • In case of fire, use the following extinguishing media: foam, CO2, water fog and/or dry chemicals.
  • Do not breathe dust, fumes, gas, mist, vapor or spray. Wash thoroughly after handling.
  • Use only outdoors or in well ventilated area. Wear protective gloves/protective clothing/eye-face protection.
  • Wear an appropriate, properly fitted respirator (NIOSH/MSHA approved) during and after application unless air monitoring demonstrates vapor levels are below applicable limits.
  • Follow respirator manufacturer’s directions for use.
  • Store in a well ventilated place. Keep container tightly closed. Keep cool.
  • Store locked up. Dispose of contents/container according to regional, national and international regulations.

Packaging & Availability

Available in
  • One gallon and five gallon sizes.
  • 55 gallon drums and 275 gallon totes are also available upon request.

Storage & Handling

Storage & Handling
  • Storage Temperature: max.120° F.
  • Shelf Life: Unlimited