Features & Benefits
- Ready-to-Use Product Features
- Features & Benefits
- Crystal clear, non-yellowing formula
- Penetrating sealer can be built to a high gloss with multiple coats
- Resists damage from water, salt, UV rays, oil and chemical stains
- Withstands vehicular traffic
Applications & Uses
- Markets
- Applications
- Application Area
- Application Instructions
For best results, surface and air temperature should be above 50°F and below 90°F. Temperature should not fall below 40°F for 24 hours following application. Do not apply if rain is expected within 12 hours of application. Stir thoroughly before and during application. A minimum of two coats is recommended. DO NOT THIN.
- First Coat: Apply first coat liberally and evenly, working in one direction. DO NOT OVERAPPLY. Remove excess material by back-rolling. Allow to dry at least 4 hours before applying second coat.
- Second Coat: For best coverage, apply second coat perpendicular to the first coat. Two coats are usually sufficient. A third coat may be necessary to ensure uniformity, depending on the porosity of the surface. One coat is usually sufficient when applied over H&C® ColorTop® Solvent-Based Solid Color Concrete Sealer 250.
Slip Resistance
Some surfaces may require a slip/skid-resistant additive for safety. Surfaces may be slippery when wet and proper preventative precautions are recommended. To increase slip/ skid resistance, add H&C® SharkGrip® Slip Resistant Additive to the coating when applying. See product data page for detailed instructions. The addition of anti-slip/skid additives will not eliminate the possibility or risk of slipping/skidding or falling.
Cleanup
Clean tools with xylene following manufacturer’s safety instructions. Use waterless hand cleaner to remove dried material from skin.
Maintenance
Clean light to moderately soiled surfaces with a 50/50 solution of H&C® ConcreteReady® Cleaner Degreaser and water. Use the cleaner at full strength for heavy soiling, such as oil and grease stains.
- Jobsite Test Section
Due to the wide variety of substrates, preparation methods, application methods and environments, it is important to create a test sample.
Limitations
Only use on interior surfaces if the area allows for good ventilation. Strong solvents, such as gasoline or brake fluid, will dull the cured film. Do not use on wood surfaces. Not recommended for immersion (underwater service).
Surface Preparation
- Newly poured concrete must be at least 28 days old. Newly installed pavers should weather a minimum of 60 days; excess joint sand should be swept off the surface prior to sealer application. All concrete must be clean, dry and free of grease, oil, paint, sealers, etc. A high-pressure water wash is recommended. To spot clean, use H&C® ConcreteReady® Cleaner Degreaser, following label instructions. If mold, mildew or fungus are present, kill and remove with a solution of one cup household bleach to one gallon of water. Wear protective eyewear, waterproof gloves and protective clothing. Quickly wash off any of the mixture that comes in contact with your skin. Do not add detergents or ammonia to the bleach/water solution. Surface should have the feel of 120-grit sandpaper at minimum, and readily absorb water. To test absorption, spray various sections of the surface to be sealed with water. If the water does not absorb rapidly, concrete must be etched with H&C® ConcreteReady® Etching Solution, following label directions. If the surface does not feel like 120-grit sandpaper following the first application, a second etching is required. (NOTE: Porous vertical surfaces, such as standard CMU, split-faced block, and exposed aggregate, generally do not require etching.) Prepared concrete must have a pH level between 6 and 10. Allow 24 hours to dry before sealing.
- Previously Painted or Stained Concrete: Make sure all previously painted or stained surfaces are in sound condition. Scrape and sand all loose material prior to the application. To ensure adequate adhesion of the sealer, scuff sand all remaining stain or paint.* Reapplication of the stain or coating may be necessary to create an even, uniform appearance. To remove light soil from the surface, use H&C® ConcreteReady® Etching Solution mixed to a 50/50 ratio with water. To remove heavy oil and grease stains, use the cleaner full strength.
- Repair: Use H&C® ConcreteReady® Quick Patch and Repair, following label directions, to fill low spots and spalled concrete. Note: Patching compounds will generally be visible through clear coatings.
*WARNING: Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. To avoid exposure to lead dust, wear proper protective equipment, such as a properly fitted respirator (NIOSH approved) and follow proper containment and cleanup procedures. For more information, call the National Lead Information Center at 1-800-424-LEAD (in U.S.) or contact your local health authority.
- Coverage Rates
Substrate sq ft/gal Concrete floors 200-300 Porous concrete 150-250 Concrete block 100-150 Split-faced block* 75-125 Fluted block 50-100 Brick (clay) 100-150 *Lightweight split-faced block may require a film-forming product due to its extreme porosity.
- Recommended Uses
For use over bare and previously coated concrete and masonry surfaces.
Commonly used on:
- Patios & walkways
- Pool decks
- Driveways
- Pavers
- Natural stone
- Chattahoochee stone
- Flagstone
- Brick & block
- Tools Required
- Natural bristle brush•High density roller cover (3/8- to ½-inch nap)
- Airless sprayer (pressure 1500 psi; tip .011 to .013 inch)
- Eye Protection
- Respiratory Protection
- Gloves
Properties
- Color
- Physical Properties
Value | Units | Test Method / Conditions | |
Dry Time (77°F, 50% RH, Dry-to-touch) | 30 mins | — | — |
Dry Time (77°F, 50% RH, Recoat) | 4 hours | — | — |
Dry Time (77°F, 50% RH, Foot traffic) | 24 hours | — | — |
Dry Time (77°F, 50% RH, Heavy traffic | 72 hours | — | — |
VOC | max. 660 | g/L | EPA Method 24 |
Finish (85 units , 60°) | Gloss | — | ASTM D523 |
Flash Point | 80.0 | °F | ASTM D93, PMCC |
Hardness | 12 - 1,000 | cycles | Tukon |
Water-Vapor Permeability | 0.001 | — | ASTM D96-66 |
Weatherometer Test (500 hours) | No failure | — | G23F Type |
Acid and Alkali Resistance (after 24 hours exposure, 2% NaOH) | Slight dulling | — | — |
Acid and Alkali Resistance (after 24 hours exposure, 5% Tide detergent) | No effect | — | — |
Acid and Alkali Resistance (after 24 hours exposure, 2% Ivory flakes) | No effect | — | — |
Acid and Alkali Resistance (after 24 hours exposure, 5% citric acid) | No effect | — | — |
Acid and Alkali Resistance (after 24 hours exposure, 100% milk) | Very slight whitening | — | — |
Acid and Alkali Resistance (after 24 hours exposure, 5% hydrochloric acid) | Very slight whitening | — | — |
Acid and Alkali Resistance (after 24 hours exposure, 5% phosphoric acid) | No effect | — | — |
Acid and Alkali Resistance (after 24 hours exposure, Mustard) | No effect | — | — |
Volume Solids | 15 - 19 | % | ASTM D2832 |
Weight Solids | 21 - 25 | % | ASTM D2832 |
Weight per Gallon | 6.9 | lbs. | ASTM D1475 |
Safety & Health
- Caution
Cautions Contains Aliphatic Hydrocarbons & Xylene
Contents are FLAMMABLE. Vapors may cause flash fires. Keep away from heat, sparks, and open flame. During use and until all vapors are gone: Keep area ventilated
- Do not smoke
- Extinguish all flames, pilot lights, and heaters
- Turn off stoves,electric tools and appliances, and any other sources of ignition.
Vapor Harmful
Use only with adequate ventilation. To avoidoverexposure, open windows and doors or use other means toensure fresh air entry during application and drying. If youexperience eye watering, headaches, or dizziness, increasefresh air, or wear respiratory protection (NIOSH approved) or leave the area. Avoid contact with eyes and skin. Wash handsafter using. Keep container closed when not in use. Do nottransfer contents to other containers for storage.
FIRST AIDIn case of eye contact, flush thoroughly with largeamounts of water for 15 minutes and get medical attention. Forskin contact, wash thoroughly with soap and water. In case ofrespiratory difficulty, provide fresh air and call physician. If swallowed do not induce vomiting. Call Poison Control Center,hospital emergency room, or physician immediately. Delayedeffects from Long Term Overexposure
Contains solventswhich can cause permanent brain and nervous system damage. Intentional misuse by deliberately concentrating and inhalingthe contents can be harmful or fatal. WARNING: This productcontains chemicals known to the State of California to causecancer and birth defects or other reproductive harm. DO NOTTAKE INTERNALLY. KEEP OUT OF THE REACH OF CHILDREN.
Packaging & Availability
- Packaging Size
- 1 gallon
- 5 gallons