company tower banner
Hallman Lindsay Company Logo

Hallman Lindsay Builder’s Legacy 220 Premium Wall Primer/Sealer

Hallman Lindsay Builder’s Legacy 220 Premium Wall Primer/Sealer are designed for preparing walls and ceilings for painting. Formulated with a higher resin-to-solids ratio allows for improved enamel holdout allowing paints to reach their full sheen in fewer coats. These thin film products require less material to prime and seal surfaces for faster spray application on residential, commercial, and institutional projects.

Product Type: Coating, Primer, Sealer, Waterborne Coating

Application Area: Ceiling Coverings, Wall

Features: Excellent Topcoat Hold-Out, Good Surface Appearance, High Strength, Pigmentable, Water-based

Application Method: Brush, Roller, Spray

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Carrier
Product Specifications
  • Vehicle Type: Ethylene-Vinyl Acetate
  • Color Tinting: White. May be tinted, up to 2 oz. per gallon, with low VOC colorants.

Features & Benefits

Product Highlights

Premium Wall Primer/Sealer is our finest drywall primer/sealer designed to create a strong seal on new drywall. This premium sealer creates a strong foundation for flat, enamel, and most waterborne epoxy topcoats. It is designed for use with our premium wall paints including Wonder Kote, Luster Kote, Earthscapes, and Artisan finishes.

Performance & Features
  • Great Enamel Hold-Out
  • Exceptional Walk-Away Appearance
  • Faster Spray Application
  • LEED v4 Credit Eligible
Benefits
  • Premium Enamel Hold-Out: Fortified enamel holdout allows topcoats to build to their true sheen faster for improved coverage and touchup qualities.
  • Versatile Application: Fast spray and easy rolling formulation allows for a versatile application. Excellent for use on drywall repair, remodel, and new construction projects.
  • Environmentally Responsible Product: This zero-VOC, LEED v4 Credit Eligible finish meets the performance needs of contractors, specifiers, property managers, and general contractors looking to meet the strictest air quality standards.

Applications & Uses

Application Area
Application Method
Recommended Usage
  • For Interior New Drywall
  • Good Enamel Holdout
  • Use in Residential, Commercial, and Institutional Construction
Applications

Drying Time: (75ºF. & 50% R.H.)

  • To touch: 1 Hour
  • To recoat: 4 Hours

Extended drying time may be expected when conditions such as high humidity, high dew point, low temperature, etc. are present. Allow product to dry thoroughly before top coating

Theoretical Coverage:
Apply at 400 sq. ft./gal. to achieve

  • 4.0 mils Wet Film Thickness
  • 1.2 mils Dry Film Thickness

When calculating working coverage, allow for application losses, texture and porosity of surface, application technique, etc.

Surface Preparation

On drywall, all taped joints and nail heads should be sanded smooth and dusted. Patch all holes and cracks with an appropriate patching compound. Let dry thoroughly, sand smooth, and prime. Surfaces must be dry, clean, and free of dirt, oil, or any other contaminants.

Warning! If you scrape, sand or remove old paint, you may release lead dust. Lead is toxic. Exposure to lead dust can cause serious illness, such as brain damage, especially in children. Pregnant women should also avoid exposure. Wear a NIOSHapproved respirator to control lead exposure. Clean up carefully with a HEPA vacuum and a wet mop.

Finishing Recommendations
  • High-performance Acrylic: Duratech Series
  • Designer Finish: Pure And Luster Series
  • Premium Finish: Wonderkote And Earthscapes Series
  • Professional Finish: Pro Kote And Renewal Series
  • Builder’s Legacy Finishes: Master Kote, Velvet Armor, And Premium Hi-build Series
Application

Mix thoroughly before use. Apply by brush, roller, or airless spray or conventional spray. Flow and leveling is best achieved by applying a full, uniform coating and working to a wet edge using overlapping strokes. Do not brush or roll excessively. Surfaces should be dry prior to paint application. Reducing material for spray application should not exceed 10%. All products are formulated ready for application. If needed, thin sparingly and do not exceed 2oz per gallon. Clean all applicators with water immediately after use.

Equipment Requirements
  • Airless: Minimum .70 GPM, 2800 PSI, .017-.021” Tip
  • HVLP: Twin-stage turbine, 5-8 PSI, .051 to .070 projector set
  • Roller: ¼” - ¾” nap shed-resistant cover or lambswool cover
  • Brush: 100% Nylon or Synthetic Blend

Properties

Color
Typical Properties
ValueUnitsTest Method / Conditions
Gloss Flat (60°)2 - 4Units-
Solid Content by Volume26 - 30%-
Solid Content by Weight40 - 44%-

Regulatory & Compliance

Compliance & Certification
Gloss Level 1
VOC Content

4 g/L (0.04 lb./Gal)

LEED v4 Credit Eligible YES

 

Safety & Health

Precautions
  • Apply only if air, surface and material temperatures remain 50°F or above during application and drying.