company tower banner
Hallman Lindsay Company Logo

Hallman Lindsay Builder’s Legacy 227 Pro Wall Primer/Sealer

Hallman Lindsay Builder’s Legacy 227 Pro Wall Primer/Sealer are designed for preparing walls and ceilings for painting. Formulated with a higher resin-to-solids ratio allows for improved enamel holdout allowing finish coats to reach their full sheen in fewer coats. These thin film products require less material to prime and seal surfaces for faster spray application on residential, commercial, and institutional projects.

Product Type: Coating, Primer, Solventless & High Solids Coating, Waterborne Coating

Application Area: Ceiling Coverings, Wall

Features: Excellent Topcoat Hold-Out, Fast Drying, Good Hiding Power, Good Surface Gloss, High Efficiency, High Solids Content, Pigmentable, Water-based

Application Method: Brush, Roller, Spray

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Carrier
Product Specifications
  • Vehicle Type: Ethylene-Vinyl Acetate
  • Color Tinting: White. May be tinted, up to 2 oz. per gallon, with low VOC colorants.

Features & Benefits

Labeling Claims
Product Highlights

Pro Wall Primer/Sealer is a commercial-grade primer designed for professional application. The slightly higher solids formula provides a high hiding finish with good enamel holdout. It is designed to provide an efficient and economical system when used with Master Kote, Pro Kote and Pro-Series finish coats.

Performance & Features
  • Pro-Series System Primer
  • High-Hiding Primer
  • Fast-Drying Formula
  • Zero-VOC, LEED v4 Credit Eligible
Benefits
  • Professional Series: This primer/sealer is designed to be used in conjunction with other Pro-Series products including Pro Kote wall finishes and Aqua Poxy 1.
  • Commercial Application Design: Pro Wall Primer/sealer provides a fast drying and high hiding seal to typical commercial substrates including drywall, tiltup, and other masonry surfaces.
  • Environmentally Responsible Product: This zero-VOC, LEED v4 Credit Eligible finish meets the performance needs of contractors, specifiers, and general contractors looking to meet the strictest air quality standards.

Applications & Uses

Application Area
Application Method
Recommended Usage
  • For Interior New Drywall
  • Primer/Sealer for All Sheens
  • Use in Residential, Commercial, and Institutional Construction
Applications

Drying Time: (75ºF. & 50% R.H.)

  • To touch: 1 Hour
  • To recoat: 2 Hours

Extended drying time may be expected when conditions such as high humidity, high dew point, low temperature, etc. are present. Allow product to dry thoroughly before top coating

Theoretical Coverage:
Apply at 400 sq. ft./gal. to achieve

  • 4.0 mils Wet Film Thickness
  • 1.3 mils Dry Film Thickness

When calculating working coverage, allow for application losses, texture and porosity of surface, application technique, etc.

Surface Preparation

On drywall, all taped joints and nail heads should be sanded smooth and dusted. Patch all holes and cracks with an appropriate patching compound. Let dry thoroughly, sand smooth, and prime. Surfaces must be dry, clean, and free of dirt, oil, or any other contaminants.

Warning! If you scrape, sand or remove old paint, you may release lead dust. Lead is toxic. Exposure to lead dust can cause serious illness, such as brain damage, especially in children. Pregnant women should also avoid exposure. Wear a NIOSHapproved respirator to control lead exposure. Clean up carefully with a HEPA vacuum and a wet mop.

Finishing Recommendations
  • High-performance Acrylic: Aquapoxy1 Series
  • Designer Finish: Pure And Luster Series
  • Premium Finish: Wonderkote And Earthscapes Series
  • Professional Finish: Pro Kote And Renewal Series
  • Builder’s Legacy Finishes: Master Kote, Velvet Armor, And Premium Hi-build Series
Application

Mix thoroughly before use. Apply by brush, roller, or airless spray or conventional spray. Flow and leveling is best achieved by applying a full, uniform coating and working to a wet edge using overlapping strokes. Do not brush or roll excessively. Surfaces should be dry prior to paint application. Reducing material for spray application should not exceed 10%. All products are formulated ready for application. If needed, thin sparingly and do not exceed 2oz per gallon. Clean all applicators with water immediately after use.

Equipment Requirements
  • Airless: Minimum .70 GPM, 2800 PSI, .017-.021” Tip
  • HVLP: Twin-stage turbine, 5-8 PSI, .051 to .070 projector set
  • Roller: ¼” - ½” nap shed-resistant cover or lambswool cover
  • Brush: 100% Nylon or Synthetic Blend

Properties

Color
Typical Properties
ValueUnitsTest Method / Conditions
Gloss Flat (60°)1 - 4Units-
Solid Content by Volume31 - 35%-
Solid Content by Weight49 - 53%-

Regulatory & Compliance

Compliance & Certification
Gloss Level 1
VOC Content

3.761 g/L (0.03 lb./Gal)

LEED v4 Credit Eligible YES

 

Safety & Health

Precautions
  • Do not apply to “hot” plaster.
  • Apply only if air, surface and material temperatures remain 50°F or above during application and drying.