Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Agrochemical Functions
- Technologies
- Product Families
- Composition
- Alkyl Aryl Polyoxylkane Ethers, Alkyl Polyethoxyethanol Phosphates, hydroxycarboxylic acids,Free FattyAcids and dimethylpolysiloxane - 90.00%
- Components ineffective as adjuvant or buffering agent - 10.00%
- TOTAL - 100.0%
Features & Benefits
- Agrochemicals Features
- Product Highlights
- Excellent spreading qualities
- Maintains spray deposit moisture
- Reduces wash-off
- Enhances spray deposition
- Low foaming properties
- General Information
- INDUCE®pH is a multifunctional spray adjuvant that is applicable for use with most pesticide products. INDUCE®pHis designed to quickly wet and spread a more uniform spray deposit over leaf and stem surfaces while improving deposition and adhesion. INDUCE®pHalso contains buffering and water conditioning agents designed to modify the pH of spray application mixtures. INDUCE®pHis recommended for use with most pesticides which are to be used with wetter/spreader type nonionic spray adjuvant.
Applications & Uses
- Markets
- Applications
- Applicable Crop
- Application Technique
- Directions for Use
- The addition of an adjuvant to some pesticide tank mix combinationsmay cause phytotoxicity to the foliage and/or fruit of susceptible crops. Prior to the addition of INDUCE®pH tospray tank mixes, the user or application advisor must have experience with the combination or must have conducted a phytotoxicity trial.
- NOTE:Spray mixes of copper-containing products, such as the fungicides containing cupric hydroxide, tribasic copper or copper oxychloride, should not be buffered below a pH of 5.0.
- INDUCE®pH may be applied by ground, CDA, Aerial or Aquatic spray equipment.For most applications, use enough INDUCE®pHto allow for uniform wetting and deposition of the spray onto leaf surfaces without undue runoff.
For use as a Nonionic Spray Adjuvant:
- Ground, Aerial, CDA:Use 1-4 pints per 100 gallons of spray.Aquatic:Use2-4 pints per 100 gallons of spray. NOTE:The above use recommendations are considered to be adequate for most uses. Some pesticides, however, may require higher rates for optimum effect. Follow the pesticide label directions when this occurs
For use as Buffering and Water Conditioning Agent:
- To adjust the pH of spray application water for a range that is considered best for most pesticides, use 1-2 pints of INDUCE®pH per 100 gallons of water.
Properties
- Formulation Type
- Physical Form
Safety & Health
- Hazards to Humans and Domestic Animals
- BEFORE USING THIS PRODUCT, READ ALL PRECAUTIONS, Directions for Use, CONDITIONS OF SALE–LIMITED WARRANTY AND LIMITATIONSOF LIABILITY AND REMEDIES.
- Maybe harmful if swallowed. May be harmful in contact with skin. Causes serious eye damage. Causes skinirritation.May be harmful if inhaled. May cause an allergicskin reaction.Keep productlocked up and out of the reachof children.Washthoroughlywithsoapand water after handling and beforeeating, drinking, chewing gum or smoking tobacco. Remove and wash contaminated clothingbeforereuse.Donottake internally.Avoidcontact with or inhalation of spray application mist if present.Do not apply this productin such a manneras to directlyexposeworkersor other persons. If productis being mixed with pesticides and/or spray adjuvants, follow all precautionarystatementson the accompanying product(s)labeling. Not for human or animal consumption.
- Personal Protective Equipment (PPE)
- Wear protective eyewear (goggles or face shield), chemical-resistant gloves, long-sleeved shirt and long pants, and shoes plus socks when using this product. Take off any contaminated clothing and wash before reuse
Packaging & Availability
- Packaging Type
Storage & Handling
- Storage and Disposal
- Store in original container only. Keep container tightly closed, do not allow water to be introduced into the contents of this container. Do not contaminate water sources by runoff from cleaning of equipment, disposal of equipment washwaters or spray waste.Combustible, do not store near heat or open flame.
- CONTAINER DISPOSAL:NON-REFILLABLE CONTAINER DISPOSAL:Do not reuse empty container. Triple rinse (or equivalent) during mixing and loading and add rinsate to spray tank. Recycling decontaminated containers is the best option of container disposal. The Agricultural Container Recycling Council (ACRC) operates the national recycling program. To contact your State and local ACRC recycler, visit the ACRC web page at www.acrecycle.org. Decontaminated containers may also be disposed of in a sanitary landfill. For help in chemical emergencies involving spill, leak, fire or exposure, call toll free 1-800-424-9300.
- REFILLABLE CONTAINER:Refill this container with adjuvants only. Do not reuse this container for any other purpose. Cleaning the container before final disposal is the responsibility of the person disposing of the container. Cleaning before refilling is the responsibility of the refiller. To clean the container before final disposal, empty the remaining contents from the container into application equipment or mix tank. Fill the container about 10 percent full with water. Agitate vigorously or recirculate water with the pump for 2 minutes. Pour or pump rinsate into application equipment or rinsate collection system. Repeat this rinsing procedure two more times. If the container is not being refilled, return the container to the point of purchase.