company tower banner
Hempel A/S Company Logo

Hempel A/S Silvium 51570

Hempel A/S Silvium 51570 is an oleoresinous general purpose aluminum topcoat with good heat resistance and good light reflection. Complies with EU Directive 2004/42/EC, subcategory i.

Product Type: Top Coat

Compatible Substrates & Surfaces: Metal, Steel, Wood

Features: Good Light Reflection

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Product Type
Gloss
Glossy
Standard shade / code
Aluminium grey 19000 *

Features & Benefits

Ready-to-Use Product Features
Features
  • For exterior and interior usage.
  • Delivers aluminum surface and light reflection.

Applications & Uses

Compatible Substrates & Surfaces
Recommended use

Hempel's Silvium 51570 is recommended as a finishing coat for protection of hot pipelines, exhaust pipes, smokestacks and other hot surfaces on steel and woodwork in mild to moderately corrosive environment, where an aluminum surface or light reflection is desired.

Application

Mixing ratio : Stir well before use.
Thinner : No thinning
Cleaner : Hempel's Thinner 08080

Tool Thinning max vol.

Application parameters Nozzle pressure: 100 bar [1500 psi]

Airless spray No thinning

Nozzle orifice: 0.017"

Air spray No thinning Not Applicable.
Brush No thinning Not Applicable.

If brush or roller application is used, more coats will be necessary to achieve the specified dry film thickness. Spray application is recommended to achieve a good surface finish. Spray data are indicative and subject to adjustment. Pressure is for a material temperature of 20°C [68°F].

Film thickness

Specification range Low High Recommended
Dry film thickness 25 micron [1.0 mils] 40 micron [1.6 mils]

25 micron [1.0 mils]

Wet film thickness 70 micron [2.5 mils] 110 micron [4 mils]

70 micron [2.5 mils]

Theoretical spreading rate 15 m²/L [610 sq ft/US gal] 9.4 m²/L [380 sq ft/US gal]

15 m²/L [610 sq ft/US gal]

 

Application conditions 
- To avoid condensation, apply on a clean and dry surface with a temperature that is at least 3°C [5°F] above the dew point.
Application remarks
- Two coats of the topcoat may be necessary to obtain full hiding power.

Drying and overcoating

Product compatibility

  • Previous coat: According to Hempel’s Specification.
  • Subsequent coat: None.

Drying time

Surface temperature 10°C 20°C 30°C 40°C
Touch dry min 60 30 20 15
Hard dry hours 9 4 2

Determined for dry film thickness 25 micron [1.0 mils] at standard conditions, see Hempel’s Explanatory Notes for details.

Drying conditions

  • To obtain the drying time stated, it is important to maintain sufficient ventilation during application, drying and curing.
  •  Condensation on the freshly applied coating should be avoided.

Overcoating details
 The surface must be dry and clean prior to application.
Other remarks
Hempel’s Specification supersedes any recommendations given in the Product Data Sheets.
 

Properties

Typical Properties
ValueUnitsTest Method / Conditions
Flash point 34.0°C
Reference dry film thickness25.0micron
Service temperature (Maximum, dry exposure only (peak))250.0°C
Service temperature (Maximum, dry exposure only)200.0°C
Specific gravity0.9kg/L
Volume solids38 ± 2%

Regulatory & Compliance

Certificates / Approvals

Complies with US FDA and EU food regulations for contact with liquid and dry foodstuff. Consult Hempel for details.

Safety & Health

VOC content
Legislation Value
EU

504 g/L [4.21 lb/US gal]

US (coatings)

504 g/L [4.21 lb/US gal]

US (regulatory)

504 g/L [4.21 lb/US gal]

China

478 g/L [3.99 lb/US gal]

 

Storage & Handling

Handling

Handle with care. Before and during use, observe safety labels on packaging and paint containers and follow all local and national safety regulations. Always consult Hempel’s Safety Data Sheet for this product along with the Product Data Sheet. For professional use only

Surface preparation

Cleanliness

  •  Remove oil, grease and other contaminants by suitable detergent cleaning.
  •  Remove salts, detergents and other contaminants by high pressure fresh water cleaning.

New build:

  • Abrasive blasting to min. Sa 2 (ISO 8501-1) / SP 6 (SSPC).
  • Remove dust, blast media and loose materials.
  • Minor areas can be cleaned by power tool to St 2 provided the surface is roughened and not polished.

Maintenance and Repair

  • Abrasive blasting to min. Sa 2 (ISO 8501-1) / SP 6 (SSPC).
  • Minor areas can be cleaned by power tool to St 2 provided the surface is roughened and not polished.
  • Remove dust, blast media and loose materials.

Roughness

  • Surface profile Fine (G) (ISO 8503-2).
Shelf life
Ambient temperature 25°C 35°C
Product 60 months 36 months

 

Shelf life from date of production, when stored in original, unopened containers. Thereafter, the product quality must be re-inspected. Always check the best before date or expiry date on the label.

 

Storage conditions

Product must be stored according to local legislation, at maximum 40 °C [104°F], without direct sunlight and protected from rain and snow.