Induron Coatings INDURAGUARD 9200

InduraGuard 9200 is a high-solids, high-build, single-component, self-priming one-coat solution for weathered galavanized and previously painted structures. It is ideal for a single coat application on transmission towers, substation structures, quanset huts, chain-link fencing, and other aged galvanized structures. InduraGuard 9200 is a modified linseed oil, metallic and ceramic pigmented coating designed for maximum corrosion protection over minimal surface preparation. InduraGuard 9200 provides excellent wetting, is easy to apply by airless spray, roller, brush or paint mitt, and can be applied up to 12 mils DFT in a single coat.

Product Type: 1K (1 component) Coating

Features: Corrosion Resistant, Excellent Wetting Behaviour, High Solids Content, Self-Priming

Application Method: Brush, Roller, Spray

    Knowde Enhanced TDS

    Identification & Functionality

    Features & Benefits

    Applications & Uses

    Application Method
    Use

    To be used for painting weathered galvanized or previously painted surfaces of transmission or communications towers, poles, substation structures, chain link fencing, buildings and railroad bridges.

    Limitations

    Not intended for immersion service, severe industrial exposures, new galvanized structures, severe acid or alkali environments, surfaces subject to splash or spillage of acids, alkalies or solvents. Do not use for surface temperatures above 200º F.

    Surface Preparation

    The surface to be coated must be dry, clean and free of contamination. Mininum surface preparation is SSPC-SP2 Hand Tool Cleaning. Can be applied to previously painted surfaces in sound condition.

    Application

    Mix thoroughly before use.

    • Mitt: Use a high quality paint mitt.
    • Airless Spray - Use .027-.029 tip; maintain 2500 psi operating air pressure at the tip without surge.
    • Brush : Use a high quality natural bristle brush.
    • Roller : Use a 3/8” nap roller with a solvent resistant core

    Thinning

    For airless spray application, thin up to 10% by volume with W-1012 as needed. Thinning is not recommended for brush, roller or mitt application. Use W-1012 for clean up.

    Danger : Rags, steel wool or waste soaked with this product may spontaneously catch fire if improperly discarded. Immediately after use, place rags, steel wool or waste in a sealed waterfilled metal container

    Climate

    Use this product only if the substrate temperature and ambient air temperature is between 35°F and 120˚F is expected not to decrease for at least two hours after application. Also, the substrate temperature must be 5°F above the dewpoint for a period of at least two hours after application to avoid condensation occurring on wet paint.

    Properties

    Physical Properties
    ValueUnitsTest Method / Conditions
    Volume Solids90 - 94%
    Weight (Depending on Color)13.1 - 15.9lbs/per gallon
    Volatile Organic Contents (Unthinned)0.6 (70)lbs/gallon (grams/liter)
    Volatile Organic Contents (Thinned (10%))1.1 (135)lbs/gallon (grams/liter)
    Typical Properties
    ValueUnitsTest Method / Conditions
    Coverage (Theoretical, at 1.0 mil dry film thickness)1475.0sq. ft/gal
    Dry Film Thickness8.0 - 12.0mils
    Wet Film Thickness8.5 - 13.0mils
    Storage Temperature35 - 100º F
    Dry Time to Touch (Air dry, 77º F)12 - 24hoursASTM D5895
    Dry Time to Handle48 - 72hours
    Dry Time to Recoat30 - 60Days
    Note

    Lower temperature, higher film build, and/or poor ventilation will retard dry time.