company tower banner
Interprovincial Cooperative Limited Company Logo

IPCO® Logic® M

1 of 10 products in this brand
IPCO® Logic® M is a post-emergent broadleaf herbicide (containing bromoxynil and MCPA) for use in wheat (spring wheat, durum and winter), barley, oats, flax (including low linolenic varieties), corn, fall rye, canary grass (for seed production), seedlings and established grasses. Logic M controls wild buckwheat, wild mustard, Lady’s Thumb, redroot pigweed, lambs’ quarters and many other broadleaf weeds.

Functions: Herbicide

HRAC/WSSA Group: 4, 6

Application Technique: Post-Emergence, Sprayers

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

HRAC/WSSA Group
Agrochemical Functions
Technologies
Active Ingredient
  • Bromoxynil (present as esters): 225 g a.e./L
  • MCPA (present as 2-ethylhexyl ester): 225 g a.e./L

Applications & Uses

Application Technique
Key Applications

Key Crops

  • Wheat (Spring, Winter, Durum)
  • Barley
  • Oats
  • Grasses (seedling, established)
  • Fall rye

Key Weeds

  • Kochia
  • Wild buckwheat
  • Lady’s Thumb
  • Volunteer canola
  • Stinkweed
Directions For Use
  • Timing: for best results, spray when weeds are in the seedling stage. Apply in good growing conditions. Application must be made before the crop shields the weeds. Do not apply more than once per season.
  • Sprayer: wash the tank and clean all filters, screens and tips. Select nozzle tips to apply the recommended volume per hectare. Flood jet type tips are not recommended. Adjust boom height to ensure uniform coverage of the weeds. For ground applications, spray at 5 – 10 kph. Ensure that all tips are in good condition and spraying the same volume.
  • Mixing: half fill the tank with clean water. Add the required amount of logic m and agitate thoroughly. Fill the tank and agitate again before use.
  • Rainfast information: rainfall within 1 hour of application of logic m with some tank mix partners may reduce effectiveness. For tank mixes, consult the label(s) of the tank mix partner(s) and observe the longest (most restrictive) rainfast period of the products involved in the tank mix. Field sprayer application: do not apply during periods of dead calm. Avoid application of this product when winds are gusty. Do not apply with spray droplets smaller than the american society of agricultural engineers (asae) coarse classification. Boom height must be 60 cm or less above the crop or ground.
  • For aerial application (wheat, barley and oats only): do not apply during periods of dead calm. Avoid application of this product when winds are gusty. Do not apply when wind speed is greater than 16 km/h at flying height at the site of application. Do not apply with spray droplets smaller than the american society of agricultural engineers (asae) coarse classification. To reduce drift caused by turbulent wingtip vortices, the nozzle distribution along the spray boom length must not exceed 65% of the wing- or rotorspan.
  • Aerial application instructions: apply only by fixed-wing or rotary aircraft equipment which has been functionally and operationally calibrated for the atmospheric conditions of the area and the application rates and conditions of this label. Label rates, conditions and precautions are product specific. Read and understand the entire label before opening this product. Apply only at the rate recommended for aerial application on this label. Where no rate for aerial application appears for the specific use, this product cannot be applied by any type of aerial equipment. Ensure uniform application. To avoid streaked, uneven or overlapped application, use appropriate marking devices.

Properties

Physical Form

Safety & Health

Precautions
  • Keep out of reach of children. Avoid contact with skin, eyes and clothing. Store the container tightly closed away from seeds, fertilizer, plants and foodstuffs. Wash concentrate from skin or eyes immediately.
  • Avoid working in spray mist. After use wash hands and other exposed skin.
  • Do not use in residential areas, which are defined as sites where bystanders may be present during or after spraying, including homes, schools, parks, playgrounds, playing fields and public buildings.
  • Apply only when the potential for drift to areas of human habitation or areas of human activity such as houses, cottages, schools, and recreational areas is minimal. Take into consideration wind speed, wind direction, temperature inversions, application equipment, and sprayer settings.
First Aid
  • Remove person from contaminated area, remove contaminated clothing. Keep patient warm, comfortable, at rest. Take container, label or product name and Pest Control Product Registration Number with you when seeking medical attention. If in eyes, hold eye open and rinse slowly and gently with water for 15–20 minutes.Remove contact lenses, if present, after the first 5 minutes, then continue rinsing eye. Call a poison control center or doctor for treatment advice.
  • If on skin or clothing, take off contaminated clothing. Rinse skin IMMEDIATELY with plenty of water for 15–20 minutes. Call a poison control center or doctor for treatment advice.
  • If inhaled, move person to fresh air. If person is not breathing, call 911 or an ambulance, then give artificial respiration, preferably by mouth-to-mouth, if possible. Call a poison control center or doctor for further treatment advice.
  • If swallowed, call a poison control center or doctor IMMEDIATELY for treatment advice. Do not induce vomiting unless told to do so by a poison control center or doctor. Do not give any liquid to the person. Do not give anything by mouth to an unconscious person.

Packaging & Availability

Availability

10 Liters

Storage & Handling

Storage

This LOGIC M formulation will solidify at temperatures below -20° C but will become usable at temperatures above 0° C. Insecticides and fungicides should be segregated from herbicides so as to prevent the possibility of cross-contamination.

Disposal
  • Recyclable container disposal: do not reuse this container for any purpose. This is a recyclable container, and is to be disposed of at a container collection site. Contact your local distributor/dealer or municipality for the location of the nearest collection site. Before taking the container to the collection site:
  1. Triple- or pressure-rinse the empty container. Add the rinsings to the spray mixture in the tank.
  2. Make the empty, rinsed container unsuitable for further use. If there is no container collection site in your area, dispose of the container in accordance with provincial requirements.
  • Returnable container disposal: do not reuse this container for any purpose. For disposal, this empty container may be returned to the point of purchase (distributor/dealer).
  • Refillable container disposal: for disposal, this container may be returned to the point of purchase (distributor/dealer). It must be refilled by the distributor/dealer with the same product. Do not reuse this container for any other purpose.