company tower banner
Jayco Chemical Solutions Company Logo

Jayco Chemical Solutions JC 1550C

JC 1550C is applied in Ultrasonics and Immersion

Product Type: Cleaner, Rust Removers

Application Area: Immersion Cleaner, Machine Parts, Ultrasonic Cleaner

Compatible Substrates & Surfaces: Aluminum, Brass, Copper, Metal, Steel

Features: Corrosion Resistant, Low Foaming

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Features & Benefits

Ready-to-Use Product Features
Features

Low foaming water soluble corrosion inhibitor Designed for use on copper, brass, and aluminum for short term storage. Prevents tarnish and maintains brilliant appearance on polished parts. Protects steel from flash rusting Highly concentrated

Applications & Uses

Markets
Application Method
Compatible Substrates & Surfaces
Normal Process
Process:

Spray Wash Systems

Concentration:

2-10% (normal range 3-5%)

Temperature:

140° F-160° F/60°C-70°C

Rinse: Yes
Dry: Air

 

Surface Compatibility

brass, copper, aluminum, and steel, stainless steel, non-metallic surfaces

Properties

Physical Form
Appearance
Clear, straw colored liquid
Typical Properties
ValueUnitsTest Method / Conditions
PH Range2022-07-08--
Specific Gravity1.02-1.03 g/mL at 25°C (77°F)--
Water SolubleSoluble--

Technical Details & Test Data

Normal Control

Dropping Bottle Method (Jayco Chemical Solutions part number: Acidity Test Kit JYT002)

  1.  Take a sample of the JC CitraPass 5220 solution from the Bath with a beaker and allow to cool to room temperature.
  2.  Measure out 10 ml, using the graduated sample bottle provided in the titration kit.
  3.  Add 1-2 drops phenolphthalein indicator
  4.  Add dropwise 5.0N N sodium hydroxide (NaOH) while counting the drops and swirling the solution.
  5.  Stop adding the drops when color changes from colorless to pink.
  6.  Calculation : Concentration of JC CItraPass 5220 (%) = Drops of 5.0N NaOH x 0.313

Conductivity
Below are readings taken with DI water. Jayco Chemical Solutions suggests making up known concentrations in customer’s operating range and water for more accurate readings
% conductivity (mS/cm)

  • 5   : 3.014 mS/cm
  • 10 :  4.187 mS/cm
  • 15 : 4.987 mS/cm

Safety & Health

Removes These Contaminants

coolants, light machining oils and particulates