company tower banner
Jayco Chemical Solutions Company Logo

Jayco Chemical Solutions JC 210

JC 210 is applied in Ultrasonics and Immersion

Product Type: Cleaner, Detergents

Application Area: Immersion Cleaner, Ultrasonic Cleaner

Compatible Substrates & Surfaces: Aluminum, Brass, Copper, Iron, Metal, Plastics, Stainless Steel, Steel

Features: Excellent Rinsability, Neutral pH

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Product Type

Features & Benefits

Labeling Claims
Ready-to-Use Product Features
Features

Neutral pH process detergent using new generation surface-active technologies Excellent rinsability Readily biodegradable Safe on ferrous, non-ferrous metals and non-metallic surfaces including plastics that are resistant to stress cracking

Applications & Uses

Markets
Application Method
Normal Process
Process:

Spray Wash Systems

Concentration:

2-10% (normal range 3-5%)

Temperature:

140° F-160° F/60°C-70°C

Rinse: Yes
Dry: Air

 

Surface Compatibility

brass, copper, aluminum, and steel, stainless steel, non-metallic surfaces

Properties

Physical Form
Appearance
Clear, straw colored liquid
Typical Properties
ValueUnitsTest Method / Conditions
PH Range2022-07-08--
Specific Gravity1.02-1.03 g/mL at 25°C (77°F)--
Water SolubleSoluble--

Technical Details & Test Data

Normal Control

Dropping Bottle Method (Jayco Chemical Solutions part number: Acidity Test Kit JYT002)

  1.  Take a sample of the JC CitraPass 5220 solution from the Bath with a beaker and allow to cool to room temperature.
  2.  Measure out 10 ml, using the graduated sample bottle provided in the titration kit.
  3.  Add 1-2 drops phenolphthalein indicator
  4.  Add dropwise 5.0N N sodium hydroxide (NaOH) while counting the drops and swirling the solution.
  5.  Stop adding the drops when color changes from colorless to pink.
  6.  Calculation : Concentration of JC CItraPass 5220 (%) = Drops of 5.0N NaOH x 0.313

Conductivity
Below are readings taken with DI water. Jayco Chemical Solutions suggests making up known concentrations in customer’s operating range and water for more accurate readings
% conductivity (mS/cm)

  • 5   : 3.014 mS/cm
  • 10 :  4.187 mS/cm
  • 15 : 4.987 mS/cm

Safety & Health

Removes These Contaminants

coolants, light machining oils and particulates