K-FLEX® TITAN™ is a flexible coextruded jacketed composite material applied to K-FLEX® NBR/PVC tubular insulation. It is a polymeric jacketed material that offers excellent flexibility, abrasion and weather resistance, making it ideal for outdoor applications.

Foam Type: Closed Cell Foam

Density: 48.0 - 96.0 kg/m³

Chemical Family: Natural Rubbers, Polyisoprenes

Physical Form: Foam

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Product Type

Features & Benefits

Resistance to Moisture Vapor

The expanded closed-cell structure and unique formulation inherently resists moisture vapor intrusion. K-FLEX® TITANTM needs no additional protection.

Applications & Uses

Applications

K-FLEX® TITANTM can be used for outdoor applications with service temperatures ranging from -70 °F to +220 °F. The applications would be consistent with those recommended for K-FLEX® Insul-Tube tubing. The product is used to enhance the weather and abuse resistance of the insulation tubing. K-FLEX® TITANTM is ideal for use on HVAC linesets and flex hose applications. K-FLEX® USA NBR/PVC elastomeric insulation products can withstand temperature “spikes” up to 250°F (121°C). Because these spikes can vary in temperature and duration, long term effects may vary. 

Outdoor Application:

K-FLEX® TITANTM provides excellent UV resistance and protection from weather. K-FLEX® TITAN’s proprietary copolymer blend jacket provides excellent protection from mechanical abuse, including incidental impact from lawn equipment such as weed wackers (plastic string type). The product has a 5-year warranty.

Direct Burial Applications: K-FLEX® TITANTM can be installed in direct burial application if the lines are above the water table and not in a flood zone. K-FLEX® TITANTM should be installed in a single layer with all butt joint and longitudinal seams completely sealed with an approved contact adhesive (see technical bulletin TA 14). Install in a PVC conduct to prevent insulation compaction or increase insulation thickness by a minimum one wall size to compensate for compaction. Backfill materials shall not contain any angular/sharp edges and shall allow for drainage. For applications below the water table or in a flood zone, install K-FLEX® TITANTM in a sealed conduct or trench

Installation
  1. Step Install: No field applied protective coating or additional jacketing required.

K-FLEX® TITANTM is durable (nonfracturing) and the skin is resistant to tearing from handling and the environment, safe to handle (nondusting and non-abrasive), and lightweight for an efficient installation. It is very flexible and easily conforms to bends. Its low modulus allows it to be pushed back for easy installation of fittings.

K-FLEX® recommends that insulation is installed on non-operational systems with clean, dry surfaces in ambient conditions between 40 °F and 100 °F. Properly sized insulation tubing can be slid over piping (tubing should be pushed, not pulled). All seams, butt joints, termination points and open ends should be sealed with an approved contact adhesive, making sure both surfaces to be joined are coated. Vapor stops should be installed as needed. K-FLEX® TITANTM may be slit longitudinally for retrofit applications. On straight runs, seams should be facing down to reduce weight/pressure on the seam. For additional protection on the longitudinal seam, apply Titan Tape over entire length of the seam. A squeegee may be used to eliminate wrinkles and air pockets. ASTM C1710, Installation Guide for Flexible Closed Cell Foams, and the K-FLEX® Installation Manual should be used as comprehensive installation guides.

Properties

Color
Physical Form
Typical Properties
ValueUnitsTest Method / Conditions
Corrosion Risk (pH)pH NeutralDIN 1988
Density3 - 6lb/ft3ASTM D1667
Dimensional Stability (Linear Shrinkage)max. 7%ASTM C534
Elongationmin. 150%ASTM D412
Flammability5.0VAASTM E84 UL 94
Hot Surface Performance (121°C)PassASTM C411 NFPA 90 A
Operating Temperature Range-70 - 220°FASTM C534
Tensile Strengthmin. 1200PsiASTM D412
Thermal Conductivity (24°C)0.23W/mKASTM C177
UV Resistance (Artificial Aging)No DeteriorationASTM G153, ASTM G154 tested to 5,000 hours
Water Vapor Permeability (Dry Cup)max. 0.01perm. inASTM E96
Water Vapor Permeance (Jacket Material)max. 0.05permsASTM E96

Regulatory & Compliance

Certifications & Compliance
Specification Compliance
  • 2012 IECC Section R403.3.1 (residential) Section C403.2.8 (commercial)
  • 2015 and 2018 IECC Section R403.4.1 (residential) Section C403.2.10.1 (commercial)
  • 2012, 2015 and 2018 IRC Section N1103.4.1
  • 2019 California Title 24 Energy Code, Section 120.3
  • ASTM E84 25/50-rated (to 1-1/2”) CAN/ULC S102.2 – 25/50 rated
  • UL 94 Flammability Classification (#E300774)
  • NFPA 90 A - 90 B
  • UL Greenguard Gold Certified

 

Technical Details & Test Data

Dimensions

Thickness Recommendations - To Prevent Condensation

SERVICE TEMPERATURE -20°F (-29°C) 50°F (10°C)
3/8” ID to 1-1/2” ID 1” 1/2”
1-1/2” IPS to 2-7/8” IPS 1” 1/2”

 

For Energy Conservation (Ashrae 90.1 - 2010)

NOMINAL PIPE OR TUBE, SIZE, INCHES < 40°F, < 4.4°C 40-60 °F, 4.4-15.6°C 105-140 °F, 40.6-60 °C

141-200°F, 60.6-93.3°C

< 1” 0.5 0.5 1 1.5
1” to 1 1/2” 1 0.5 1 1.5
1 1/2” to 4” 1 1 1.5 2

 

Pipe “R” Values Per Square Foot (All Sizes Are Nominal)

Nominal Insulation I.D. 1/2” WALL 3/4” WALL 1” WALL

1-1/2” WALL, Insul-Tube

1/4” 4.2 6.4 10.1 17.9
3/8” 3.8 5.8 9.1 15.6
1/2” 3.6 5.7 8.4 14.4
5/8” 3.5 5.8 8 13.6
3/4” 3.3 5.7 7.9 12.9
7/8” 3.4 5.8 7.6 12.3
1-1/8” 3.3 5.7 7.5 11.5
1-3/8” 3.4 5.5 7.2  
1-5/8” 3.3 5.4 6.9  
1-1/2” IPS 2.8 4.7 6.2  
2-1/8” 3.2 5.1 6.6  
2” IPS 3.1 5    
2-1/2” IPS 3      
2-5/8” 3.1      

Packaging & Availability

Availability

K-FLEX® TITANTM is black in color and is available in 1/2”, 3/4”, 1” and 1-1/2” wall thicknesses, non-slit and preslit 6’ length tubes. It is available in diameter sizes ranging from 1/4” I.D. to 2-1/8” I.D. across all wall thicknesses and additional IDs dependent on wall thickness. Coils are also available up to 1” wall thickness.