Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Technologies
- Product Families
- Chemical structure
Features & Benefits
- Labeling Claims
Applications & Uses
- Product Application
Cosmonate CG-32S is a special modified MDI, which is used for a wide variety of purposes, such as automobile sound absorbers, ISF, headrests and mold foams, for furniture. It has good air ventilation and good flowability and moldability, making its use advantageous in forming complex molds.
Properties
- Physical Form
- Appearance
- brown liquid
- Typical Properties
Value | Units | Test Method / Conditions | |
NCO Content | 32.3 ~ 33.3 | wt% | ASTM D 1638 |
Viscosity (25°C) | max. 40 | cps | ASTM D 1638 |
Specific gravity (25℃) | 1.21 ~ 1.22 | - | ASTM D 1638 |
Boiling point | Below 5 | ℃ | - |
Vapor pressure (25°C) | negligible | mmHg | - |
Flash point | 177 ~ 218 | ℃ | - |
Safety & Health
- Safety and Health
Contact with the skin can cause inflammation including a rash, while contact with the eyes can cause severe pain, and visual disturbance may result in the event of excessive exposure. Inhalation of the vapor of MDI can cause bronchial asthma, headaches, or breathing difficulties, and its ingestion can cause irritation and inflammation of the gastrointestinal tract. In cases of contact with the skin, rinse the affected area completely with plenty of water or soapy water. In cases of contact with the eyes, rinse immediately with plenty of water or soapy water for 15 minutes, and seek professional medical help. In cases of MDI vapor inhalation, move the affected individual to a place where there is plenty of fresh air, keep him/her in a warm, stable condition, and perform artificial respiration if needed. In cases of ingestion, allow the affected individual to vomit with their head positioned lower than the hip to prevent suffocation from respiratory tract inhalation, and provide symptomatic treatment. Seek medical help if necessary. in the event of a fire, extinguish with a carbon dioxide fire extinguisher. In the event of a large fire, extinguish with water.
Packaging & Availability
- Packaging Type
- Product packaging
cosmonate CG-32S is packed in single 230kg drum
Storage & Handling
- Storage and Handling
Contact with the skin can cause inflammation including a rash, while contact with the eyes can cause severe pain, and visual disturbance may result in the event of excessive exposure. Inhalation of the vapor of MDI can cause bronchial asthma, headaches, or breathing difficulties, and its ingestion can cause irritation and inflammation of the gastrointestinal tract. In cases of contact with the skin, rinse the affected area completely with plenty of water or soapy water. In cases of contact with the eyes, rinse immediately with plenty of water or soapy water for 15 minutes, and seek professional medical help. In cases of MDI vapor inhalation, move the affected individual to a place where there is plenty of fresh air, keep him/her in a warm, stable condition, and perform artificial respiration if needed. In cases of ingestion, allow the affected individual to vomit with their head positioned lower than the hip to prevent suffocation from respiratory tract inhalation, and provide symptomatic treatment. Seek medical help if necessary. in the event of a fire, extinguish with a carbon dioxide fire extinguisher. In the event of a large fire, extinguish with water.