COSMONATE MC-85W is a special liquid modified MDI developed for the production of seat cushion foam, and is popularly used in the production of cushion pads and headrest pads requiring excellent workability, formability and a high degree of hardness. In particular, the product ’s hardness has been enhanced to enable its widespread application in the production of seat cushions for automobiles as well as cushions for sofas and chairs, and bicycle pads.
Properties
- Physical Form
- Appearance
- light brown liquid
- Typical Properties
Value | Units | Test Method / Conditions | |
NCO Content | 34.3 ~ 35.3 | wt% | ASTM D 1638 |
Viscosity (25°C) | max. 20 | cps | ASTM D 1638 |
Specific gravity (25℃) | 1.21 ~ 1.23 | - | ASTM D 1638 |
Boiling point | 208 | ℃ | — |
Freezing point | Below 10 | ℃ | — |
Vapor pressure (25°C) | negilgible | mmHg | — |
Flash point | 177 ~ 218 | ℃ | — |
Safety & Health
- Safety and Health
Contact with the skin can cause inflammation including a rash, while contact with the eyes can cause severe pain, and visual disturbance may result in the event of excessive exposure. Inhalation of the vapor of MDI can cause bronchial asthma, headaches, or breathing difficulties, and its ingestion can cause irritation and inflammation of the gastrointestinal tract. In cases of contact with the skin, rinse the affected area completely with plenty of water or soapy water. In cases of contact with the eyes, rinse immediately with plenty of water or soapy water for 15 minutes, and seek professional medical help. In cases of MDI vapor inhalation, move the affected individual to a place where there is plenty of fresh air, keep him/her in a warm, stable condition, and perform artificial respiration if needed. In cases of ingestion, allow the affected individual to vomit with their head positioned lower than the hip to prevent suffocation from respiratory tract inhalation, and provide symptomatic treatment. Seek medical help if necessary. in the event of a fire, extinguish with a carbon dioxide fire extinguisher. In the event of a large fire, extinguish with water.
Packaging & Availability
- Packaging Type
- Product packaging
Cosmonate MC-85W is packed in single 230kg drum or in bulk
Storage & Handling
- Storage and Handling
The optimal storage temperature for MC-85W is 20~30℃. Caution is needed to prevent moisture from being mixed in the storage container, which should be sealed by dry nitrogen gas if possible. When working with MDI, proper safety equipment should be worn, and a ventilation or gas mask should be used if necessary. After work, wash completely with soapy water. Contaminated work clothes should be washed and cleaned for the next use.