L & L 163 Primer/Sealer is a high-build, waterborne, elastomeric barrier coating. Its unique blend of premium acrylic resins and pigments combine to form a durable, mildew-resistant film with exceptional adhesion and flexibility. L&L 300 is a breathing mastic which allows damaging substrate moisture to escape, while protecting against ultra-violet, water and air-flow intrusion.

Product Type: 1K (1 component) Coating, Elastomeric Coating, Primer, Waterborne Coating

Compatible Substrates & Surfaces: Concrete, Fiberglass, Galvanized Steel, Iron, Metal, Steel

Features: Acid Resistant, Breathable, Chemical Resistant, Durable, Excellent Flexibility, Excellent Substrate Adhesion, Good Weather Stability, Mercury Free, Mildew Resistant, Rapid Drying Properties, Resilient, UV Resistant, Water Resistant

    Knowde Enhanced TDS

    Identification & Functionality

    Features & Benefits

    Features

    VOC compliant.

    Fast Drying.

    Single Component

    Contains no lead, mercury, or asbestos

    Provides exceptional adhesion and flexibility when applied to: Primed ferrous and non-ferrous metal, galvanized steel, masonry, wood, fiberglass, transite and most construction, insulation and roofing materials.

    Base and saturant coats in the L&L Moisture and Air-Flow Reinforced Systems.

    Applications & Uses

    Primary Uses
    • Architectural restoration.
    • Seals and fills interior and exterior masonry, stucco, concrete and previously painted surfaces
    • Above-grade waterproofing and damp-proofing.
    • Air-flow management (e.g. in nuclear power facilities)
    • Plywood and particle board primer/sealer.
    • Seals dry wall and sheet rock
    • Primes and upgrades amny friable thermal insulation materials.
    • Fumigation containment in tobacco storage warehouses.
    • Dust control: Seals joints and seams on conveyors, dust collectors, elevators and other material-handling equipment
    Why Use L&L Primer/Sealer?
    • Promotes adhesion on hard-to-stick-to materials.
    • Seals porous surfaces, requiring less finish coatings.
    • Easy to apply and cleans up with soap and water.
    • Reinforceable with L&L Polyester mat, Polyester mesh and Dynel cloth.
    • It's Elastomeric: Capable of stretching in excess of 12 times its original size and then returning.
    Application Equipment

    Brush: Best results will be achieved using brushes with hog or other animal bristles. Quality nylon-bristle brushes may also be used.

    Roller: Pressure fed or hand roller with 1" to 1½" nap cover.

    Airless Spray Pump: Graco Bulldog 3:1 No. 221-061 fed by Graco Monarch 5:1 transfer pump No. 206-393

    Fluid Hose: 3/8" or ½" ID with ¼" ID whip-end section

     

    Recommended Substrate Condition

    All surfaces to be coated must be clean, dry and free of dirt, oil, grease, mildew, rust, wax, chalking or peeling coating and any foreign matter which could prevent proper adhesion. Never apply to surfaces which pond water.

    Theoretical Spreading Rate Chart

    Brush, Roller and Airless Spray Grade: 

    Dry Film Thickness Wet Film Thickness Ft² Per Gallon

    Gallons Per 100 Ft²

    1 mil 2.22 mil 722 0.1385
    2 mil 4.44 mil 361 0.277
    4 mil 8.88 mil 180.5 0.554
    6 mil 13.32 mil 120.33 0.831
    8 mil 17.76 mil 90.25 1.108
    10 mil 22.20 mil 72.2 1.385
    12 mil 26.64 mil 60.16 1.662
    14 mil 31.08 mil 51.57 1.939
    16 mil 35.52 mil 45.1 2.215
    18 mil 39.96 mil 40.11 2.493
    20 mil 44.40 mil 36.1 2.77

    Note: The actual spreading rate depends on a number of factors such as: Surface profile and porosity, weather conditions, over-spray and application techniques. Use a wet film thickness gage at regular intervals during application. 

    Properties

    Typical Properties
    ValueUnitsTest Method / Conditions
    Application Tempetaure Range40 - 125°F
    Density8.76lbs/gal. USASTM D1475
    Dry (Recoat)1.5Hours
    Dry (Through)1.5Hours
    Dry (To Touch)1.5Hours
    Service Temperature Range20 - 200°F
    Tensile Elongationmin. 1260.80%ASTM D2370
    Volume Solids45.0%ASTM D2697
    Water Vapor Permeability0.2297Perm .inASTM D1653

    Technical Details & Test Data

    Viscosity

    L&L 163 Primer/Sealer is manufactured in two viscosities:

    • "Light" brush, roller & airless spray grade
    • "Standard" brush, roller & airless spray grade

    When choosing viscosity range, consider factors such as surface profile and porosity, required film thickness and application methods.

    Storage & Handling

    Handling and Storage

    L&L 163 Primer/Sealer requires no mixing or thinning. Cleans up with soap and water when wet. Xylene required to remove dried material. Protect from freezing. Never apply at temperatures below +40°F. or when freezing temperatures are likely to occur before Primer/Sealer cures. Discontinue application three hours before sunset. Do not apply when rain is likely to occur. Shelf-life: 18 months when stored indoors at +40°F. to +100°F. Keep container sealed when not in use. Read and understand Material Safety Data Sheets before using product.