Knowde Enhanced TDS
Identification & Functionality
- Ingredient Origin
- Cleaning Ingredients Functions
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- HII Features
- Key Features
- Based on BioLoop technology
- 100% renewable
- No skin or eye irritancy
- No ecotoxicity
- Biodegradable
- Medium foam
- Good detergency
- Great wetting on glass
- A green alternative to alcohol ethoxylates
Applications & Uses
- Markets
- Applications
- Home Care Applications
- I&I Cleaning Applications
- Applications
Excellent detergency:
- Can be used in hard surface cleaners and general cleaners. In formulations that contain alcohol ethoxylates then use BioLoop 84L as a green alternative. Also the SDS classifications will help ensure negative impact on the hazard classification of the end product.
Excellent wetting on glass:- Can be used in a new generation of bio-based glass cleaners.
Properties
- Physical Form
- Odor
- Characteristic
- Appearance
- Light amber liquid
- Typical Properties
- Specifications
Value | Units | Test Method / Conditions | |
Solids Content | 74 - 76 | % | — |
Cloud Point (1% Aqueous) | 80 - 88 | °C | — |
Composition | Bioloop surfactant | — | — |
Pour Point | -8.0 | °C | — |
HLB Value | 14.9 | — | — |
Viscosity (at 25°C) | 539.0 | cPs | — |
Specific Gravity (at 20°C) | 1.08 | — | — |
Flash Point (Alcohol Ethoxylates) | min. 150 | °C | — |
Surface Tension (0.1% Aqueous) | 39.2 | mN/m | — |
Value | Units | Test Method / Conditions | |
Color (Gardner) | max. 5 | — | — |
pH (5% Aqueous) | 6 - 8 | — | — |
Technical Details & Test Data
- Foaming Profile
Test method : A 0.1% solution is prepared and aerated for 30 seconds and then stopped. The degree of foaming is assessed initially and then after 1, 3 and 5 minutes.
Conclusion : When compared to our full range of surfactants would be classed a MEDIUM foam surfactant.
- Detergency Profile
Test method : A formulated soil is applied to a painted disk and then aged in an oven. The disk is then soaked in a detergent solution for 10 minutes and then rotated for a further 5 minutes. The % soil removal is then measured.
Results :
Sample % soil removal Blank 20.1 BioLoop 84L 81.5
Conclusion : The % soil removal indicates that BioLoop 84L has a HIGH detergency ranking- Substrate Wetting
Test method : A 0.5% solution is prepared and is dropped onto various substrates. The contact angle is then measured using a goniometer. The angle is measured initially and then after 5 seconds. The lower the angle the better the product wets the substrate.
Glass
Sample Contact Angle Initial Contact Angle - 5 sec
Water 46 45 BioLoop 84L 17 8