NXT® Epoxy Primer is a two component, high-solids epoxy primer applied with a sand broadcast for use with NXT decorative wear surfaces.

Product Type: 2K (2 component) Coating, Epoxy Coating, Primer, Solventless & High Solids Coating

Compatible Substrates & Surfaces: Masonry

Application Method: Roller

Chemical Family: Epoxy & Epoxy Derivatives

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Features & Benefits

Advantages
  • Ultimate bond for decorative wear surfaces.
  • Easily roller applied
  • Provides a barrier between decorative wear surfaces and substrate below.
  • Reduced pinholes in the decorative topping.

Applications & Uses

Application Method
Compatible Substrates & Surfaces
Suitable Substrates
  • Concrete
  • Concrete Slabs
  • Cement Terrazzo
  • Cement Mortar Bed
  • Existing Masonry and Brick
Installation

Approximate Coverage

2 Gallon (7.6 L) Kit

180–266 ft2 (16.7–24.7 m² ) at 12–18 mils (0.3–0.5 mm)

10 Gallon (38 L) Kit

900–1330 ft2 (83.6–123.6 m² ) at 12–18 mils (0.3–0.5 mm)

Mixing

Allow kits of NXT Epoxy Primer to acclimate to 65–75°F (18-24°C) before mixing. Add complete contents of Part B to complete contents of Part A and mix with a low speed drill (400 – 600 rpm) until mix is homogeneous and streak free. To ensure complete blending pour the mixture into a second pail and mix again.

Application

For proper application instructions refer to TDS230 Substrate Preparation And Primer Guide for Laticrete Self-leveling Products. Field visits by LATICRETE personnel are for the purpose of making technical recommendations only and not for supervising or providing quality control on the jobsite.

To be used with the following Overlays: NXT Level SP

  • Gray part #: 9600-0050-21

NXT Level DL

  • Gray part #: 0907-0055-21
  • White part #: 0908-0055-22

Cleaning and Disposal

Clean tools and equipment with Xylol*. Cured material must be removed mechanically. Dispose of waste material in accordance with local, state or federal regulations.

* Warning : Xylol is flammable and hazardous. Use with proper ventilation. Wear safety goggles and gloves. Consult with SDS before using Xylol.

Maintenance

Non-finish LATICRETE and NXT installation materials require no maintenance but installation performance and durability may depend on properly maintaining products supplied by other manufacturers.

Properties

Working Properties
ValueUnitsTest Method / Conditions
Tack Free Dry5 to 7hours-
Physical Properties
ValueUnitsTest Method / Conditions
Tensile Bond Strength350 (2.4)psi(MPa)ASTMC 1583
Pot Life15 - 25minutes-
Time to Apply Overlay (Sand Broadcast Needed)14 - 16hours-

Safety & Health

Cautions
  • Before using any NXT produ
  • Perform a mock-up to ensure product will perform as required
  • Check www.laticrete.com for any technical bulletins or updated information about the product and its application
  • Wear gloves and protective goggles
  • Keep out of reach of children.

Packaging & Availability

Packaging
  • KIT : 2 Gal (7.6 L)
    • PART #: 0909-0302-2
      • 2 steel pail / 96 kits per pallet
  • KIT :10 Gal (38 L)
    • PART #: 0909-0010-2
      • 2 steel pail / 12 kits per pallet

Storage & Handling

Shelf LIfe

Containers are to be kept tightly sealed and stored in a cool, dry place. Shelf life is one year when stored properly, between 40-105 °F (4-41°C). Keep from freezing.

Limitations

  • Do not install when surface temperature is below 50°F (10°C), when ambient temperature is expected to be below 60°F (16°C) during placement or before material takes final set or when temperature will be above 90°F (32°C).
  • Adhesives/mastics, mortars and grouts for ceramic tile, pavers, brick and stone are not replacements for waterproofing membranes. When a waterproofing membrane is required, use a LATICRETE® Waterproofing Membrane on top of the cured NXT underlayment.
  • Do not apply NXT Epoxy Primer to areas where there is standing water.
  • Not for submerged applications.