Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Polymer Name
- Technologies
- Product Families
Features & Benefits
Applications & Uses
- Markets
- Applications
- Plastics & Elastomers End Uses
- Plastics & Elastomers Processing Methods
- Application examples
● Pump parts ● fittings ● valve body ● Die cutting plates ● Construction parts for the chemical apparatus engineering
Properties
- Flame Rating
- Mechanical Properties
- Thermal Properties
- Typical Properties
- Electrical Properties
Value | Units | Test Method / Conditions | |
Density | 0.91 | g / cm³ | ISO 1183 |
Yield Stress | 32 | MPa | ISO 527 |
Elongation at Break | 70 | % | ISO 527 |
Modulus of Elasticity (Tensile test) | 1400 | MPa | ISO 527 |
Modulus of Elasticity (Bending test) | 1400 | MPa | ISO 178 |
Flexural Strength | 45 | MPa | ISO 178 |
Impact Strength | Without break | KJ/m² | ISO 179 |
Notched Impact Strength | 7 | KJ / m² | ISO 179 |
Ball Indentation Hardness (H358/30) | 70 | MPa | ISO 2039-1 |
Time Elongation Stress (1% elongation) | 4 | MPa | DIN EN ISO 899-1 |
Coefficient of Sliding Friction (Against steel) | 0.35 | — | — |
Sliding Wear (against steel) | 11 | μm / km | — |
Melting Temperature | 162 | °C | ISO 3146 |
Value | Units | Test Method / Conditions | |
Thermal Conductivity | 0.22 | W/(K m) | DIN EN 12939 |
Specific Heat Capacity | 1.7 | J / (gK) | — |
Coefficient of Linear Expansion | 16 | 10^5(K-1) | — |
Temperature Range (long-term) | 0 - +80 | °C | — |
Operating Temperature Range (short-term) | 100 | °C | — |
Fire Behavior | HB | — | UL 94, IEC 60695 |
Dielectric Constant | 2.25 | — | IEC 60250 |
Value | Units | Test Method / Conditions | |
Moisture Absorption (Normal climate to saturation) | max. 0.01 | % | DIN EN ISO 62 |
Water Absorption (up to saturation) | max. 0.01 | % | DIN EN ISO 62 |
Value | Units | Test Method / Conditions | |
Dielectric Dissipation Factor | 33 | — | IEC 60250 |
Specific Volume Resistance | min. 10^16 | Ωcm | IEC 60093 |
Surface Resistance | 10^14 | Ω | IEC 60093 |
Dielectric Strength | 52 | kV/mm | IEC 60243 |
Tracking Resistance | CM 600 | - | IEC 60112 |
Regulatory & Compliance
- Certifications & Compliance