Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Product Type
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Product Highlights
- The transparent film left by NOCOR S2 is easily removed and will not interfere with additional machining, gaging, or assembly steps
- Barium free and contains very low levels of volatile organic compounds as applied
- Highly-concentrated and economical, Master STAGES™ synthetic corrosion inhibitors leave a thin, water soluble film to provide one-to-two months of rust and oxidation protection. Clean and very low foaming, Master STAGES synthetic corrosion inhibitors are barium-free with very low V.O.C. content.
- Additional Information
- Industrial Use Only
- Consult Master Fluid Solutions before using on any metals or applications not specifically recommended.
- This product should not be mixed with other metalworking fluids or metalworking fluid additives, except as recommended by Master Fluid Solutions, as this may reduce overall performance, result in adverse health effects, or damage the machine tool and parts. If contamination occurs, please contact Master Fluid Solutions for recommended action.
- Master STAGES™ is a trademark of Master Chemical Corporation d/b/a Master Fluid Solutions.
Applications & Uses
- Markets
- Application Method
- Use Level
- 3.0 - 10.0 %
- Application Guidelines
- NOCOR S2 can be applied by dip, spray, brush, or flow-coating.
- Since NOCOR S2 is low foaming, it is often applied as a final stage rinse in a spray or dip washing system.
- Concentrations of 3% - 5% are generally used for two to four weeks indoor storage.
- Concentrations of 5% - 10% are generally used for four to eight weeks indoor storage.
- As with all water soluble corrosion inhibitors, avoid stacking or packaging parts while still wet.
- Product Applications
Applications : Corrosion inhibition
Metals : Ferrous metals
Industries : Automotive and general industry- Mixing Instructions
- Recommended usage concentration in water: 3.0% - 10.0%.
- To help ensure the best possible working solution, add the required amount of concentrate to the required amount of water (never the reverse) and stir until uniformly mixed.
- Recommended Metalworking Concentrations
Design concentration range : 3.0% - 10.0%
Properties
- Odor
- Amine (Concentrate)
- Physical Properties
Value | Units | Test Method / Conditions | |
Flash Point (Concentrate) | max. 210 | °F | ASTM D93-08 |
pH (Concentrate as Range) | 9.7 - 10.0 | - | - |
pH (Typical Operating as Range) | 9.3 - 9.6 | - | - |
Coolant Refractometer Factor | 2.0 | - | - |
V.O.C. Content | 173 | g/l | ASTM E1868-10 |
Cleaner Conductivity Factor | 0.0017 | - | - |
Titration Factor | 0.7 | - | CL-1 Titration Kit |
Number of Cleaner Vials | 1.0 | - | CL-1 Titration Kit |
Cleaner Indicator A or B | A | - | CL-1 Titration Kit |
Regulatory & Compliance
- Product Compliance
NOCOR S2 is free of barium.
Technical Details & Test Data
- Test Data
Concentration by Conductivity
Concentration by Titration
Packaging & Availability
- Packaging
- 1-gallon jug
- 5-gallon pail
- 54-gallon drum
- 270-gallon tote