Knowde Enhanced TDS
Identification & Functionality
- Product Type
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Feature
Asbestos free
Applications & Uses
- Markets
- Compatible Substrates & Surfaces
- Material Preparation
Do not thin this product.
- Limitations
- Keep from freezing
- Apply between 50ºF and 110º F.
- Cold temperatures extend tack time.
- Application
This product is for industrial use only. It should be applied by trained and qualified craftspeople. Be sure surfaces are clean and dry. 22-65 Mono-Tack Spray Adhesive can be spray applied with air atomizing spray equipment. Low ratio pumps with regulators for air and material can be used. Explosion proof equipment is not necessary. Pin welding may be done immediately. Apply a uniform coat of 22-65 to the insulation for fastest tack development. To bond press firmly in place. Contact Mon-Eco Industries, Inc. for detailed instructions.
- Clean Up
Water, 44-10, or Xylol
- Coverage
- 300 to 400 sq.ft/gal.
- The coverage rate is dependent on the surface being covered and the application method.
Properties
- Physical Form
- Typical Properties
Value | Units | Test Method / Conditions | |
Service Temperature | -40 to 195 | °F | - |
Weight | 9.2 | lbs/gal | - |
Non Volatile (Average) | 61.0 | % by Weight | - |
Bonding Time (Depend on Temperature, Humidity, Film Thickness) | 0 - 12 | min | - |
VOC (Less Water, Exempt Solvents) | max. 0.48 | lbs/gal | - |
Regulatory & Compliance
- Certifications & Compliance
- Specification Compliance
- Complies with LEED v4 ID&C, BD&C
- Collaborative for High Performance Schools (CHPS) EQ 7.1.1
- California Dept. of Public Health (CDPH) Standard Method v1.2
- Criteria of MAS Certified Green® Program TVOC Emissions at 14 days, (Certificate Number MAS-1700746)
- Meets requirements for LEED® IEQ Credit 4.1: Low Emitting Materials: Adhesives & Sealants.
- Low VOC Emitting Products per certificate number MAS-1400262, LEED v4, CHPS, CDPH Standard Method V1.1
- ASTM C916 Type I
- NFPA 90A& 90B
- Meets requirements for LEED® IEQ Credit 4.1: Low Emitting Materials: Adhesives & Sealants
Safety & Health
- Caution
- Use with adequate ventilation.
- Avoid prolonged or repeated breathing of vapor.
- Avoid prolonged or repeated contact with skin.
- In an emergency call a physician.
- Keep out of reach of children.
- Surface Burning Characteristics
Applied to Inorganic Reinforced Cement Board
USC CNC Flame Spread 5 5 Smoke Developed 0 0
Tested as applied at a coverage rate of 300 sq. ft/gal.
- Flammability
Wet - Non-flammable