company tower banner
NEI Corporation Company Logo

NANOMYTE® TC-5001-UVP

1 of 74 products in this brand
NANOMYTE® TC-5001-UVP is a single component formulation designed to protect zinc-plated and galvanized steel from corrosion and degradation. The product is a hard, dense nanocomposite coating that provides barrier protection for the alloy surface. The coating resists scratching and chipping, and strongly adheres to the substrate. The formulation has enhanced weatherability and is designed to meet customers’ requirements for film thickness and curing conditions.

Product Type: 1K (1 component) Coating, Solventborne Coating, Top Coat

Compatible Substrates & Surfaces: Composites, Metal, Plastics, Steel

Features: Excellent Substrate Adhesion, Good Scratch Resistance, Good UV Protection

Application Method: Brush, Roll Coater, Spray

Similar Products

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Features & Benefits

Labeling Claims

Applications & Uses

Application Method
Compatible Substrates & Surfaces
Coating Application
  • Spraying : 
    When surface preparation is complete and surface is dry and free of dust, begin application using a high volume, low pressure (HVLP) spray gun with a 1.0 mm tip and a pressure of approximately 25 to 30 psi. On a piece of cardboard, first test spray to achieve a 6” to 8” elongated pattern approximately 1” wide in the middle and fluid enough to cover but not puddle. Once the desired spray pattern is achieved, spray one coat in a cross-pattern; left to right, then up and down. To spray small pieces or tight locations you can use a “Preval” sprayer - a small, disposable sprayer that can spray any liquid and holds approximately 6oz, ideal for touch ups as well.
  • Rolling :
    Using an ultra-smooth, high-density foam roller, pour TC-5001-UVP into a roller pan and completely saturate the roller. Apply in a cross-pattern; left to right, then up and down as quickly as possible as the coating dries fast. Avoid excessive pressure on the roller to achieve a better looking finish.
  • Brushing :
    Select the appropriate size brush width based on the surface being coated. Apply TC-5001-UVP in a cross-pattern, up and down, then left and right. To obtain the best results, do not overwork the coating as it dries fairly quickly. Do not bear down on the brush.
Surfaces

Zinc-plated and Galvanized Steel

Application Notes
  • Test Area :
    Given the wide variety of metals and the various methods and environments of application, it is advisable to first use TC-5001 on a test piece or in an inconspicuous area to evaluate the resulting adhesion and appearance. There will often be some enhancement in luster (gloss) from the original surface. TC-5001-UVP is a clear coating, however on some white paints or powder coats, the color may be altered to appear off-white or slightly yellow, particularly if a thick coat is applied.
  • Clean Up :
    Clean tools and flush equipment thoroughly with acetone immediately after application is completed and before product dries. Once the coating is dry, solvent cleaning is no longer effective.
  • Care & Maintenance :
    For normal cleaning, wash the coated surface with a hose or wipe down with a damp cloth to remove dirt and spills on the surface. Although TC-5001-UVP is scratch resistant, it is not scratch proof. Do not use abrasive cleaners or scouring pads. If an area becomes damaged or is mechanically abraded, lightly sand the area with 220 grit sandpaper and reapply the coating. If the substrate itself is damaged, make the necessary repairs first, then re-apply TC-5001-UVP.
  • Weatherability and UV Protection :
    For best performance, when applying to UV-sensitive surfaces (e.g., plastics, composites), apply as thick a coating as possible, and/or ensure a minimum DFT of 0.5 mils (10-15 microns). Select the appropriate surface preparation protocol (cleaning and/or surface treatment, priming) and test to ensure coating adhesion has been maximized. Some surfaces (e.g., certain paints, plastics and composites) may require a primer, such as NANOMYTE® SR-Primer. Samples intended for weatherability testing should be conditioned for a minimum of 1 week at 25°C with at least 50% relative humidity.

Properties

Physical Form
Physical Properties
ValueUnitsTest Method / Conditions
Solids Content18 - 20 %
Typical Properties
ValueUnitsTest Method / Conditions
Coverage800 - 1200ft²/gallon
Curing Temperature20 - 150°C
Recommended Thickness per Coat (Dry mils)0.5 - 1.2
Recommended Thickness per Coat (Wet mils)1.5 - 2.0
VOCsmax. 100g/L
Weatherability (DFT = 0.5 mils/10 - 15 μm)min. 1,000hoursASTM D4587 (G154, Cycle 1)
Note
* Coating can be made thinner by diluting with recommended solvents

Technical Details & Test Data

Surface Preparation

Ensure bare metal surfaces to be coated are clean and dry. Remove all oil, grease, dust, dirt and other foreign material before using appropriate metal cleaner and/or applying TC-5001-UVP. To ensure that the surface is free of oil and grease, use a lint-free white cloth with a solvent, such as alcohol or acetone, and clean until the cloth remains white after wiping. TC-4001 can then be applied per application instructions below. Remove scale and light to medium rust using appropriate rust stabilizer and/or scale remover. Heavy rust must be sandblasted or ground off. If desired, metal may be primed or painted before using TC-4001-UVP as the final topcoat.

Curing
  • Room Temperature Curing (25 °C) :
    Under ambient conditions, a single coat will be dry to the touch in 1-2 hours and cured in 24 hours.
  • Accelerated Curing (105 °C – 150 °C) :
    Alternatively, the coating can be applied to the surface, dried in ambient air for 10 minutes, and then heated to at least 105 °C for 1 hour. An oven, blow dryer or heat gun may be used (maximum temperature is 150 °C). After heating, coated parts should be allowed to cool before handling. TC-5001-UVP will completely wet bare metal surfaces if properly prepared or if primed / painted. Only one coat is required to cover substrates, but multiple coats are allowable. Under ambient conditions, a single coat is 5 - 15 μm (0.2 – 0.6 mil) thick and will be dry to the touch in 1-2 hours and cured in 24 hours. Multiple coats can be applied in 10 minute intervals while the previous coat is still tacky. Two to three coats should result in a final coating that is 25 - 40 μm (1-1.5 mil) thick.

Storage & Handling

Storage and Handling

Precautions for Safe Handling :
Appropriate personal protective equipment should be used at all times. Provide good ventilation or extraction. Avoid prolonged or repeated breathing of vapor. Avoid contact with eyes, skin and clothing. Wash hands thoroughly after handling. Keep away from heat, sparks, flames and other sources of ignition. Take measures to prevent the buildup of electrostatic charge.

Conditions for Safe Storage :
Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Residual vapors might explode on ignition. Do not apply heat, cut, drill, grind or weld on or near this container.