Nexa3D xMODEL 2505 is a high resolution dental model material suitable for modeling and thermoforming applications. It is a meth-acrylate based resin suitable for use on Nexa3D printers, including NXE400 and NXD200.printers. Curing profiles are developed for 100 and 50 µm layer heights.

Processing Methods: 3D Printing, Stereolithography

End Uses: Dental Applications, Modeling Material, Prototyping

Density: 1100.0 - 1100.0 kg/m³

Tensile Strength: 54.0 - 54.0 MPa

    Knowde Enhanced TDS

    Identification & Functionality

    Chemical Family
    Plastics & Elastomers Functions
    Technologies

    Applications & Uses

    Plastics & Elastomers Processing Methods
    Usage Notes

    The material should be processed at room temperature. Nexa3D xMODEL 2505 should be well mixed before each print job, color deviation or failed prints might occur when not mixed thoroughly. It’s recommended to use a bottle roller (roller bench) for mixing with suitable ceramic beads for at least 30 minutes. Pour it slowly in the vat and wait a couple minutes, until the bubbles are gone before starting the print job.

    Keep container tightly closed in a room temperature, well-ventilated place. Keep container dry. If Material is not being used fill it back through a filter in the corresponding material bottle. The filter prevents to fill cured pieces or failed prints back into the bottle. Uncured Nexa3D xMODEL 2505 must be disposed of or incinerated in accordance with local regulations.

    The mechanical and physical properties of Nexa3D xMODEL 2505 are highly dependent on the printing parameters used as well as part geometry. It is common that validated workflows need to be adjusted for unusually thick or thin geometries.

    Properties

    Color
    Mechanical Properties
    ValueUnitsTest Method / Conditions
    Tensile Stress at Break54MPaASTM D638
    Young’s Modulus2500MPaASTM D638
    Elongation at Failure4%ASTM D638
    Flexural Strength83MPaASTM D790
    Flexural Modulus2150MPaASTM D790
    Typical Properties
    ValueUnitsTest Method / Conditions
    Hardness73Shore DASTM D2240
    Viscosity (30°C)80mPasCone/Plate Rheometer
    Liquid Density1.1g/cm³ASTM D4052-18a
    Solid Density1.2g/cm³ASTM D792

    Technical Details & Test Data

    Validated Workflows
     Exposure Parameters   NexaX default     
     Primary Wash   2min, Isopropyl Alcohol     
     Secondary Wash   2min, Isopropyl Alcohol (low saturation) with Ultrasonic     
     Dry   30min air dry     
     Cure   30min in xCure, ambient temperature 

     

     Exposure Parameters   NexaX default    
     Primary Wash   3min, distilled water Ultrasonic bath     
     Secondary Wash   3min, distilled water (low saturation) Ultrasonic bath, soft brush if needed 
     Blow Off   Blow dry with pressurized air 
     Dry   30min dry in 40°C warming cabinet 
     Cure   30min in xCure, ambient temperature 

     

     Exposure Parameters   NexaX default     
     Primary Wash   2min, xClean in xWash station low agitation speed     
     Dry   10 min drip dry     
     Secondary Wash   2min, Isopropyl Alcohol (low saturation) with Ultrasonic 
     Dry   30min air dry 
     Cure   30min in xCure, ambient