company tower banner
NuGenTec Company Logo
FluoSolv® AP is a proprietary blend of nonflammable hydrofluoroethers (HFEs) and trans-1,2- dichloroethylene (t-DCE) and alcohol engineered for defluxing as well as white residue removal. It is a drop-in replacement for defluxing blends of n-propyl bromide (nPB) and similar vapor degreasing solvents. It can also be used as a substitute for other cleaners such as Asahi AK-225 (blend of HCFC-225 ca/cb) & HCFC-141b both of which are ozone depleting substances and have been banned from production.

Product Type: Cleaner, Degreasers, Rust Removers

Application Area: Machine Parts

Compatible Substrates & Surfaces: Aluminum, Brass, Ceramic, Copper, Elastomers & Rubbers, Metal, Plastics

Certifications & Compliance: ISO 14001, ISO 9001

Features: Degreasing, Grime Cleaning, Low Toxicity

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Features & Benefits

Ready-to-Use Product Features
User Benefits

FluoSolv™ AP solvent blending technology leverages the chemical solvency of the fluid as well as its physical properties such as high density, low surface tension and low viscosity for optimal performance. Our research has shown that to clean metal surfaces in the shortest amount of time the solvent must flow extremely close to the surface to “catch & release” contaminants. It is ideally balanced to deliver performance, worker safety and desirable environmental properties.

  • Non-ozone depleting chemical (ODC)
  • Drop-in replacement; no equipment modifications
  • Low global warming potential (GWP)
  • Low toxicity; high allowable exposure limit (AEL)
  • No ceiling on instantaneous exposure
  • Chemically stable; will not go acid

Applications & Uses

Markets
Application Area
Solvent Recycling

FluoSolv™ AP is a stable azeotropic blend easy to reclaim and reuse by simple distillation process. Commercially available modular recycling units can easily be added to realize sizable savings in solvent usage. Solvent recovery yields are typically in the range of 80 to 95%.

Properties

Physical Form
Appearance
Clear, colorless
Physical Properties
ValueUnitsTest Method / Conditions
Boiling Point43.0°C
Density (At 25°C)1.26kg/liter
Surface Tension (At 25°C)21.0dyne/cm
Viscosity (At 25°C)0.46cPs
Vapor Pressure (At 25°C)41.0kPa
Heat of Vaporization (At bp)64.3cal/g
Global Warming Potentialmax. 30
Ozone Depleting ChemicalNo
Volatile Organic Compounds (VOC)756.0g/l
Allowable Exposure Limit (AEL)352.0ppm
Worker Exposure CeilingNoppm
KB Value92.0
Flammability
ValueUnitsTest Method / Conditions
Flash Point (CC)NoneASTM D93
Flash Point (OC)NoneASTM D1310
Flammability in Air (Lower Explosivity)6.1vol%ASTM E681
Flammability in Air (Upper Explosivity)11.1vol%ASTM E681
Composition
ValueUnitsTest Method / Conditions
Hydrofluoroethersmax. 30wt%
Trans-dichloroethylenemin. 70wt%
Iso-propyl Alcoholmax. 5wt%
Watermax. 100ppm
Non-Volatile Residue (Drums)max. 100ppm
Non-Volatile Residue (Pails)max. 200ppm

Regulatory & Compliance

Certifications & Compliance
Chemical Inventories

Technical Details & Test Data

Material Compatibility

FluoSolv™ AP is compatible with all metals, ceramic and other non-conducting materials. Most elastomeric materials are compatible except fluoroelastomers such as Viton & Kalrez which tend to swell. It is recommended that all materials be tested prior to use.

  Compatible

Additional Testing Required

Metals

Aluminum, Copper, S/S, Titanium,Brass, Tungsten

-
Elastomers Neoprene, Butyl Rubber Viton, Kalrez
PLastics HDPE, PTFE, Nylon, PVC, Epoxy, Phenolic Acrylic, ABS

Safety & Health

Worker Safety

Data from acute toxicity studies of various ingredients has demonstrated that FluoSolv™AP blend has low toxicity. It has a calculated AEL (Acceptable Exposure Limit) of 335 ppm based on its individual components. None of the ingredients in FluoSolv™ AP have any chronic or acute toxicity associated with them which makes it a worker friendly solvent. Please refer to the MSDS for information on detailed exposure limits and toxicity-related data. NuGenTec FluoSolv™ AP exhibits no closed cup or open cup flash point and is not classified as a flammable liquid per established definitions by NFPA or DOT, however being volatile, vapors may become flammable in air. Flash point data and vapor flammability limits in air are shown.

Packaging & Availability

Packaging Type
Packaging & Availability

FluoSolv™ AP is available in three package sizes

  • 55-gal lined metal drums (net wt. 55)
  • 5-gal lined pails (net wt. 55 lb.)
  • 1 gal amber glass bottles (net wt. 11 lb.)

Note: Drum & Pail have phenolic liner. All package sizes are inventoried at Emeryville, CA & Atlanta, GA. Lead times are 1-3 business days after receipt of order.

Storage & Handling

Storage

FluoSolv™ AP is thermally & chemically a very stable solvent. It is non-reactive,has low water solubility and will not oxidize or degrade when exposed to air. It is not affected by any sunlight or other sources of UV radiation. Common industrial practice should be implemented for storage; keep away from human food source and extreme temperature conditions. Freezing temperatures will cause the drums to compress and hot conditions will balloon the drum. The product in any case is perfectly usable.