Turbo Fuse Series 440 SI is an advanced thixotropic formula is designed to polymerize instantly by absorbing surface moisture. The product's performance has been tested with a variety of materials, and is recommended for a multitude of applications. The fast curing qualities make it especially desirable in high speed industrial production. Turbo Fuse Series 440 SI is ideal for use in applications that require a gel like, viscous adhesive. It is also ideal for applications on vertical, angled or overhead surfaces. For extreme gap fill, the use of an accelerator is highly recommended.

Product Type: 1K (1 component) Adhesive

Compatible Substrates & Surfaces: Aluminum, Elastomers & Rubbers, Metal, Steel

Chemical Family: Cyanoacrylates

Features: Fast Curing, General Purpose, Good Gap Filling Capabilities, High Performance, High Viscosity, Thixotropic

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Chemical Family

Features & Benefits

Applications & Uses

Compatible Substrates & Surfaces
Applications

Because of the thick gel consistency, it works especially well in poor fitting applications such as rough metal or ceramic repair, unfinished metal to metal bonding, and metal to rubber.

Properties

Appearance
Clear hard (Cured), Clear white gel
Soluble in
Acetone, MEK, Amide, Methylene Chloride
Physical Properties
ValueUnitsTest Method / Conditions
Base Compound (Resin)Surface insensitive ethyl cyanoacrylate--
ViscosityNot applicable-thixotropic gel--
Specific Gravity1.05--
Flash Point170 - 200°FTagliabue closed cup
Typical Properties
ValueUnitsTest Method / Conditions
Average Set Time (Full Cure 24 hours, Metal)30 - 60seconds-
Average Set Time (Full Cure 24 Hours, Plastic)20 - 40seconds-
Average Set Time (Full Cure 24 Hours, Rubber)5 - 10seconds-
Average Strength (Steel)22.0N/mm²-
Loctite® Equivalent454.0--
Permabond® Equivalent2011.0--
Cured Properties
ValueUnitsTest Method / Conditions
Softening Temperature300°F-
Service Temperature-65 to 180°F-
Hardness Barcol65--
Dielectric Constant (at 1 MHz)3.33--
Specific Resistance8.6x10²Ω-cm-
Tensile Shear Strength2500psi-
Gap Filling0.01inches-

Regulatory & Compliance

Quality Standards

Technical Details & Test Data

Material Set Up Time
Aluminum to Aluminum 20 to 30 seconds
Steel to Steel 50 to 100 seconds
Phenolic to Phenolic < 90 seconds
Polycarbonate to Polycarbonate 50 to 70 seconds
Rubber to Rubber 10 to 25 seconds

Storage & Handling

Shelf Life
1 Year