company tower banner
Politem Plastik Company Logo

JURAPOM® X60 724 NC00 1000

1 of 5 products in this brand
JURAPOM® X60 724 NC00 1000 is a pom-c, 20% glass bead, natural (Heat stab.) for injection application.

Polymer Name: Polyacetal Homopolymer (POM)

Flexural Modulus: 4000.0 - 4000.0 MPa

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Chemical Family
Technologies

Properties

Mechanical Properties
ValueUnitsTest Method / Conditions
Tensile Modulus2750MPaISO 527-2
Young Modulus3000MPaISO 527-2
Tensile Strength at Break45MPaISO 527-2
Tensile Strength at Yield25MpaISO 527-2
Elongation at Break30%ISO 527-2
Elongation at Yield1.55%ISO 527-2
Flexural Modulus4000MpaISO 178
Flexural Strength55MpaISO 178
Izod notched impact (23°C)5.5kJ/m2ISO 180/1A
Izod notched impact (-30°C)4.5kJ/m2ISO 180/1U
Typical Properties
ValueUnitsTest Method / Conditions
Density1.53g/cm3ISO 1183
Ash Content20%ISO 3451
Water Absorption (Saturation in water 23°C)0.65%ISO 62
Water absorption,(Equilibrium value) (50% RH, 23°C)0.2%ISO 62
Thermal Properties
ValueUnitsTest Method / Conditions
MFR/MFI(Melt Flow Rate,250 °C 2,16 kg)10-13g/10 minISO 1133
VICAT (50 N - 50 °C/h)143°CISO 306
HDT A (1.80 Mpa)90°CISO 75-2
HDT B (0.45 Mpa)129°CISO 75-2
Processing Properties
ValueUnitsTest Method / Conditions
Melting Temperature, DSC165°CISO 11357-1/-3
Melt Temperature, for processing190-200°C
Cylinder Settings180-210°C
Screw DesignUniversal Type
Mould Temperature, injection moulding80-120°C
Moulding shrinkage (parallel,2mm)1.7%ISO 294-4
Moulding shrinkage (normal,2mm)1.7%ISO 294-4
Electrical Properties and Flammability
ValueUnitsTest Method / Conditions
Flame Rating (1.6 mm)HBclassUL94
Comparative Tracking Index (CTI, 3 mm-Solution A)600VIEC 60112
Volume Resistivity1.00E+12Ohm.mIEC 60093
Surface Resistivity100000000000000ohmIEC 60093