Value | Units | Test Method / Conditions | |
Tensile Strength | max. 70.0/60.0 | MPa | ISO 527-2 |
Flexural Strength | max. 95.0/45.0 | MPa | ISO 178 |
Elongation at Yield | 5.0/35.0 | % | ISO 527-2 |
Flexural Modulus (23°C) | 2400.0/1300.0 | MPa | ISO 178 |
Charpy Notched Impact Strength (-20°C) | 5 | kJ/m² | ISO 179 |
Charpy Unnotched Impact Strength (23°C) | No Break/No Break | - | ISO 179 |
Charpy Notched Impact Strength (23°C) | 5.0/20.0 | kJ/m² | ISO 179 |
Charpy Unnotched Impact Strength (-20°C) | No Break | kJ/m² | ISO 179 |
Value | Units | Test Method / Conditions | |
Molding Shrinkage - Flow | 1.2 | % | ISO 294-4 |
Molding Shrinkage - Across Flow | 1.4 | % | ISO 294-4 |
Density | 1.13 | g/cm³ | ISO 1183/A |
Value | Units | Test Method / Conditions | |
Heat Distortion Temperature A (120°C/h at 1820kPa) | 70 | °C | ISO 75/1 |
Vicat Softening Tempurature A (50°C/h at 9,81N) | 215 | °C | ISO 306 |
Vicat Softening Tempurature B (50°C/h at 49,05N) | 200 | °C | ISO 306 |
Heat Distortion Temperature B (120°C/h at 455kPa) | 180 | °C | ISO 75/1 |
Value | Units | Test Method / Conditions | |
Glow Wire Flammability Index - GWFI (2 mm) | 750 | °C | IEC 60695-2-12 |
UL-94 Flammability (1.6 mm) | V2 | - | UL94 |