Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Fillers Included
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
- Product Families
Features & Benefits
- Materials Features
Applications & Uses
- Plastics & Elastomers Processing Methods
Properties
- Flame Rating
- Flame Rating
- UL 94 HB
- Filler Content
- 28 - 32
- Mechanical Properties
- Physical Properties
- Thermal Properties
- Flammability
Value | Units | Test Method / Conditions | |
Tensile Strength | max. 130.0/90.0 | MPa | ISO 527-2 |
Flexural Strength | max. 210.0/150.0 | MPa | ISO 178 |
Hardness (15 s) | 77 | Shore D | D2240 |
Elongation at Break | 3.5/6.0 | % | ISO 527-2 |
Flexural Modulus (23°C) | 7700.0/5400.0 | MPa | ISO 178 |
Charpy Notched Impact Strength (-20°C) | 13 | kJ/m² | ISO 179 |
Charpy Notched Impact Strength (23°C) | 18.0/21.0 | kJ/m² | ISO 179 |
Value | Units | Test Method / Conditions | |
Molding Shrinkage - Flow | 0.3 | % | ISO 294-4 |
Molding Shrinkage - Across Flow | 1.1 | % | ISO 294-4 |
Density | 1.33 | g/cm³ | STANDARD ISO 1183 |
Value | Units | Test Method / Conditions | |
Heat Distortion Temperature B (120°C/h at 455kPa) | 250 | °C | ISO 75/1 |
Heat Distortion Temperature A (120°C/h at 1820kPa) | 240 | °C | ISO 75/1 |
Vicat Softening Tempurature B (50°C/h at 49,05N) | min. 220 | °C | ISO 306 |
Value | Units | Test Method / Conditions | |
Glow Wire Flammability Index - GWFI (2 mm) | 650 | °C | IEC 60695-2-12 |
UL-94 Flammability (1.6 mm) | HB | - | UL94 |
Regulatory & Compliance
- Certifications & Compliance
Packaging & Availability
- Country Availability
- Regional Availability