Value | Units | Test Method / Conditions | |
Surface Resistance | 10^13 | Ohm | IEC 60093 |
Shrinkage | 0,05 | % | ISO 2577 |
thermal conductivity | 0,69 | W(m*K) | ASTM E 146-01 |
heat distortion temperature | min. 200 | °C | ISO 75-2° |
tracking resistance | CTI 600 | level | IEC 60112 |
surface weight | 4 | g/m2 | ISO 10352 |
Specific Density | 1,68 | g/cm3 | ISO 1183 A |
fibre length | 25 | mm | DF PA3.01 |
Curing Time | 90 | sec | ISO 12114/1 |
Specific volume resistance | 1014 | Ohm x cm | IEC 60093 |
fibre Content | 20 | % | ISO 1172 |
Flexural modulus | 8.7 | N/mm2 | ISO 14125 |
Flexural strength | 125 | N/mm2 | ISO 14125 |
impact strength | 55 | KJ/m2 | ISO 179 |
limited oxygen index | 34 | % | ISO 4589 |
dielectric strength | 20 | KV/mm | IES 60243-1 |
arc resistance | 183 | s | ASTM D 495 |
thermal expansion coefficient | 33,07 | Ppm * K-1 | ASTM 696 |
Water absorption | max. 0,12 | % | ISO 62 |
Value | Units | Test Method / Conditions | |
Flammability | V 0 (3,2) | — | — |
Storage & Handling
- Handling and Storage
- Storage condition store dry at max
- 25 °C and out of direct sun light
- Molding time > 25 sec
- /mm
- Molding pressure 80 - 120 bar
- Molding temperature 135 - 155 °C