company tower banner
Polytek Development Corp Company Logo

Polytek Development Corp Poly 75-70

Polytek Development Corp Poly 75-70 Liquid Rubbers consist of two parts (A and B), which, after mixing, cure at room temperature to flexible rubber. Molds made with Poly 75-70 products are excellent for casting concrete, plaster and wax. In addition, Poly 75-70 molds can be used to cast various resins and foams when properly prepared. Poly 75-70 Liquid Rubbers are formulated for good economy with high performance and durability.

Polymer Name: Polyurethane Thermoset Elastomer (unspecified)

End Uses: Mold Making

Features: Cost Effective, Durable, Flexible, High Performance, Pourable

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Chemical Family
Technologies

Features & Benefits

Features
  • Firm yet flexible mold rubbers
  • Ideal for demanding, high-production casting and forming of concrete
  • Dimensionally stable - molds can last for years
  • Abrasion resistant for long mold life
  • Easy-to-use, forgiving formulations

Applications & Uses

Markets
Plastics & Elastomers End Uses
Mixing and Curing
  • Before use, be sure that Parts A and B are at room temperature and that all tools are ready. Surface and air temperatures should be above 60°F during application and for the entire curing period.
  • Check mix ratio. Weigh Part B into a clean metal or plastic mixing container and then weigh the appropriate amount of Part A into the same container. Mix thoroughly. Hand mixing with a Poly Paddle is best to avoid mixing air into the rubber. While mixing, scrape the sides and bottom several times to ensure thorough mixing. Pour the rubber as soon after mixing as possible for best flow and air bubble release. Vacuum degassing helps to provide bubble-free molds, but is usually not necessary.
  • Allow rubber to cure at room temperature, 77°F (25°C). Carefully demold after approximately 16 hours. Final cure properties are obtained in about seven days, but molds may be used with care after curing for 24-48 hours. Heat accelerates the cure -- low temperatures slow the cure. Avoid curing in areas where the temperature is below 60°F (15°C).
  • Both Parts A and B react with atmospheric moisture and, therefore, should be resealed or used up as soon as possible after opening. Before resealing, Poly Purge, a heavier-than-air, dry gas, can be sprayed into open containers to displace moist air and extend storage life. For 55-gallon drums of Parts A and B, affix Drierite® cartridges on the small bung during dispensing to protect product from moist air entering the drum.

Properties

Physical Form
Typical Properties
ValueUnitsTest Method / Conditions
Mix Ratio By Weight1A:1B
Hardness70Shore A
Pour Time40minutes
Demold Time (at 73°F)16hours
Cured ColorGray
Mixed Viscosity3000cP
Specific Volume27in3/lb
Specific Gravity1.05
Elongation724%
Tensile Strength938psi
Die C Tear Strength299pli

Technical Details & Test Data

Model Preparation
  • Porous models, such as wood, plaster, stone, pottery or masonry must be sealed. Multiple coats of paste wax dried and buffed will seal most surfaces. Potters soap can be used as a sealer for plaster. Lacquer, paint, PVA, and Pol-Ease® 2350 Release Agent also work well as sealers for many surfaces. The properly-sealed model should then be coated with a release agent (e.g., Pol-Ease® 2300 Release Agent). Alternatively, PolyCoat, a sealer and semi-permanent release agent, can be used on most porous or non-porous models. Porous models must be vented from beneath to prevent trapped air from forming bubbles in the rubber.
  • Models made of sulfur-containing modeling clay (e.g., Roma Plastilina) should be sealed with shellac. [CAUTION: When shellac is used as the sealer, it must be thoroughly coated with release agent because polyurethane rubbers bond tenaciously to shellac.]
  • Non-porous models (e.g., metals, plasticine, wax, glazed ceramics, fiberglass and polyurethanes) should be coated with release agent such as Pol-Ease® 2300 Release Agent or PolyCoat.
  • If there is any question about the compatibility between the liquid mold rubber and the prepared model surface, perform a test cure on an identical surface to determine that complete curing and good release are obtained.
Product Details
  • SOFTENING THE RUBBER: Add Poly 74/75 Part C Softener to 75-Series products for a lower viscosity mix and a softer cured rubber. When using Part C, cure time is longer and there is some loss of strength in the rubber and increased tendency to shrink after repeated castings. Determine the quantity of Part C required through experimentation.
  • ACCELERATING THE CURE: Cure time can be shortened with the addition of an Accelerator, such as Poly 74/75 Part X, or by adding heat. By adding 1% Poly 74/75 Part X (by weight of total mix) to Poly 75-80, the working time is reduced to approximately 10 minutes and demolding is possible in as little as 6 hours. Exercise caution when using Part X since the rapid onset of gelling may trap air bubbles on or near the surface of the model. Heat also accelerates the cure. It is recommended not to exceed 140°F (60°C).
  • USING THE MOLD: Typically, no release agent is necessary when casting plaster or wax in Poly 75-Series molds. For casting plaster: sponge, dip or spray the mold with Pol-Ease® Mold Rinse and then pour plaster on the wet mold to reduce air bubbles in the plaster and aid release. For casting resin, first spray the mold with Pol-Ease® 2300 Release Agent or PolyCoat. For casting concrete, use a form release, such as Pol-Ease® 2650 or 2601. Avoid solvent-containing releases since they can cause mold distortion (i.e., shrinkage or swelling). After repeated casting with certain resins, plaster and concrete, molds may shrink slightly since these materials extract oils from the mold. The proper selection of release agent and/or barrier coat can minimize this effect. If shrinkage becomes evident, a light application of Pol-Ease® Mold Dressing can help to restore the mold to its original dimensions. Poly 75-Series molds last many years if stored undistorted on a flat, non-porous surface in a cool, dry location out of direct sunlight. If occasional outdoor use is required, Poly 75-59, 75-65 and 75-80 perform best and UV resistance can be improved by adding Poly UV Additive. Add 0.5% UV Additive to the total mix weight to reduce the characteristic surface degradation caused by sunlight. Never store Poly 75-Series molds outside as UV exposure will eventually degrade the rubber.
  • CLEAN UP: Wipe tools clean before the rubber cures. Denatured ethanol is a good cleaning solvent, but is highly flammable and must be handled with caution. Coat work surfaces with wax, Pol-Ease® 2300 Release Agent or PolyCoat so cured rubber can be removed.

Safety & Health

Safety
  • Part A: Keep out of reach of children. Avoid breathing fumes, vapors or mists. Use with adequate general or local exhaust ventilation to minimize exposure levels. If needed, a NIOSH-approved respirator with organic vapor cartridge may be used. If inhaled and breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing. Wear impervious gloves, such as butyl rubber or nitrile rubber. Take off contaminated clothing and wash before reuse. Wash skin thoroughly with soap and water after handling. If skin irritation occurs, get medical help. Wear eye protection, such as chemical safety glasses/googles. If in eyes, rinse cautiously with water for several minutes, removing contact lenses if present and easy to do. If eye irritation occurs, get medical help.
  • Part B: Keep out of reach of children. Do not breathe fumes, vapors or mists. Use with adequate general or local exhaust ventilation to minimize exposure levels. If needed, a NIOSH-approved respirator with organic vapor cartridge may be used. If inhaled, remove victim to fresh air and keep at rest in a position comfortable for breathing. Wear impervious gloves, such as butyl rubber or nitrile rubber. Take off contaminated clothing and wash it before reuse. Contaminated work clothing should be not allowed out of the work area. Wash skin thoroughly with soap and water after handling. If skin irritation occurs, get medical help. Wear eye protection, such as chemical safety glasses/googles. If in eyes, rinse cautiously with water for several minutes, removing contact lenses if present and easy to do. If eye irritation occurs, get medical help. If spilled, collect spillage and avoid release to the environment.

Storage & Handling

Shelf Life

For best results, store products in unopened containers at room temperature (60-90°F/15-32°C). Use products within six months. Part Bs darken with age, but product performance is not affected.