Rotuba Company Logo

Rotuba H3

Rotuba H3 is a scented acetate.

Polymer Name: Cellulose Acetate (CA)

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Plastics & Elastomers Functions
Technologies

Features & Benefits

Applications & Uses

Drying Conditions

It is preferred to use desiccant dryers, at reduced temperatures and drying times. 150°F for 2 hours is a target with dew point between -20°F and -40°F. Too high of temperatures and drying times will burn out the fragrance. In the absence of a desiccant dryer, the injection molding machine hopper may be used. Tray dryers may also be used.

Properties

Typical Properties
ValueUnitsTest Method / Conditions
Elongation (73.4°F, 50RH%)32%ASTM D638
Izod Impact Strength of Notch (73.4°F, 50RH%)3.2ft-lb/inASTM D256
Accelerated Aging (72 Hrs. Wt. Lost, 180°F)0.8%ASTM D706
Tensile Strength at Upper Yield (73.4°F, 50RH%)5350psiASTM D638
Flextural Strength at Yield (73.4°F, 50RH%)8400psiASTM D790
Flow Temperature329°FASTM D569
Modulus of Elasticity x 105 (in Flexture, 73.4°F, 50RH%)2.05psiASTM D790
Rockwell Hardness - R Scale (73.4°F, 50RH%)93ASTM D785
Soluble Matter lost (73.4°F)0.2%ASTM D570
Specific Gravity (73.4°F, 50RH%)1.28ASTM D792
Water Absortion (24Hr Immersion, 73.4°F) Total2.3%ASTM D570
Tensile Strength at Fracture (73.4°F, 50RH%)6700psiASTM D638
Deformation under load (cold flow) method A (Dry) Load 2000 psi (122°F)2%ASTM D621
Tensile Strength at Fracture (158°F, 50RH%)3650psiASTM D638
Deformation under load (cold flow) method A (Dry) Load 1000 psi (122°F)1%ASTM D621
Izod Impact Strength of Notch (-40°F, 50RH%)1.1ft-lb/inASTM D256

Regulatory & Compliance

Technical Details & Test Data

Typical Molding Conditions

Scented Cellulose Acetate
Barrel Temp Starting Profile.

Flow H3
Rear 450°- 470°F
Center 450°- 470°F
Front 450°- 470°F
Nozzle 460°- 480°F

Scented Cellulose Acetate Propionate
Barrel Temp Starting Profile.

Flow H3
Root 315°- 325°F
Rear - Root 325°- 335°F
Rear - Center 335°- 345°F
Center 360°- 370°F
Front 390°- 410°F
Nozzle 390°- 410°F

Pressures

Flow H3
Moveable Half 1700 / 1300 PSIG
Back Pressure 0 – 50 PSI

 

Mold Temperatures
  • SOFT FLOWS BELOW MS - 100°F – 140°F
  • HARDER FLOWS - 100°F – 180°F
Cycle Times
  • INJECTION (3) - 8 – 12 sec.
  • BOOSTER - 6 – 12 sec.
  • CURE - 40 – 70 sec.
Tooling

The mold vent for the tool should be .002” to .003”. If this is not the case, mold temperatures could be elevated to help drive off volatiles thereby reducing surface blushing. (180°F – 220°F)

Mold Temperature Regulation

Most molding thermolators use hot water as their medium. In the case of elevated mold temperatures as shown above, oil thermolators should be used as they can achieve high temperatures of 220°F and higher without turning to steam.