A commercial marine and cruise industry coating designed specifically to coat, insulate and protect hot and cold piping and drains, foam insulation, HVAC Units, cooling towers, fan rooms, ducts, plenums, walls, ceilings and expansion joints.
- Surface Preparations
- Simply stated the steel surface must be:
- Clean: No staining to white rag when rubbed across steel surface
- Dry: No visible moisture on the steel surface
- Tight: No loose material when a wire brush is pulled across the surface of the metal
- Application
Theoretical Coverage
9.3 m²/liter (100 Ft2/Gall) at 16 Mils wet , add 20% for loss volume.
Method of Application :Airless Spray, Brush, Roller
Mixing
Mix thoroughly with power agitator ensuring that foaming doesn't occur by introducing air. Ensure mixing equipment is clean and free from contaminants such as oils and greases.
Thinner
5% Water Maximum
Airless Spray
Recommended
- Tip Range 0.53-0.58 mm (21-23 thou)
- Total output fluid pressure at spray tip not less than 211 kg/cm² (3000 p.s.i.)
- Mixed material temperatures should be between 30-35°C (86 - 95°F) for optimum spraying
Conventional Spray
Application by conventional spray is not recommended.
Brush
Application by brush is recommended for small areas only. Multiple coats may be required to achieve specified film thickness.
Roller
Application by roller is recommended for small areas only. Multiple coats may be required to achieve specified film thickness.
Cleaner
Water
Work Stop / Cleanup
Do not allow material to remain in hoses, gun or spray equipment. Thoroughly flush all equipment with Cleaner. Once units of paint have been mixed they should not be resealed and it is advised that after prolonged stoppages work recommences with freshly mixed material. Clean all equipment immediately after use with cleaner. It is good working practice to periodically flush out spray equipment during the course of the working day. Frequency of cleaning will depend upon amount sprayed, temperature and elapsed time, including any delays. Do not exceed pot life limitations. All surplus materials and empty containers should be disposed of in accordance with appropriate regional regulations/legislation.
Welding
In the event welding or flame cutting is performed on metal coated with this product, dust and fumes will be emitted which will require the use of appropriate personal protective equipment and adequate local exhaust ventilation.
- Limitations
In-line heaters should not be used unless absolutely necessary. For maximum performance the curing temperature should be kept below 35°C. Particular care should be taken to avoid exceeding this in localized areas when artificial heating is introduced.The climatic conditions within the tank must be controlled to maintain a maximum relative humidity of 50%. The drying times and overcoating intervals may alter due to various on-site factors such as tank configuration and ventilation rates.
- Applications
- Cold Piping and drainsDucts
- Foam insulation
- Stainless Steel parts Walls, Ceilings
- Plenums
- HVAC units
- Expansion Joints
- Cooling towers
Properties
- Color
- Typical Properties
- Performance Properties
Value | Units | Test Method / Conditions | |
Sheen | Matte | — | — |
Volume Solids | 51.0 | % | ISO 3233:1998 |
Mix Ratio | One component system | — | — |
Flash Point (Typical) | min. 100 | °C | — |
Drying Information (32 WFT, Touch Dry, 15°C) | 12 | Hours | ISO 9117/3:2010 |
Drying Information (32 WFT, Hard Dry, 15°C) | 24 | Hours | ISO 9117-1:2009 |
Drying Information (32 WFT, Touch Dry, 25°C) | 8 | Hours | ISO 9117/3:2010 |
Drying Information (32 WFT, Hard Dry, 25°C) | 18 | Hours | ISO 9117-1:2009 |
Drying Information (32 WFT, Touch Dry, 35°C) | 5 | Hours | ISO 9117/3:2010 |
Drying Information (32 WFT, Hard Dry, 35°C) | 12 | Hours | ISO 9117-1:2009 |
Value | Units | Test Method / Conditions | |
Water Absorption (%) | 10.0 | — | ASTM D471 |
Average Permeabiity | 22.21 | Perms | ASTM D1653 |
Elongation | 1078.51 | % | ASTM D2370 |
Tear Resistance | 135.91 | lbf/in | ASTM D624 |
Direct Impact | min. 150 | lbs | ASTM D2794 |
Reverse Impact | min. 150 | lbs | ASTM D2794 |
Salt Spray (Blasted Hot Rolled (3,200 HRS at 16 DFT, Blisters)) | None | — | ASTM B117 |
Salt Spray (Blasted Hot Rolled (3,200 HRS at 16 DFT, Rust)) | 6.0 | % | ASTM B117 |
Salt Spray (Blasted Hot Rolled (3,200 HRS at 16 DFT, Undercut)) | 2.0 | mm | ASTM B117 |
Technical Details & Test Data
- Substrate Temperature
Overcoated By 10°C 15°C 25°C 35°C Min Max Min Max Min Max AQ200 No data No data 24 hrs Infinite 18 hrs Infinite 10 hrs Infinite
Packaging & Availability
- Packaging Type
- Package Size
5 gallons pails, 50 gallon drums , 250 gallon totes
Storage & Handling
- Shelf Life
- 36 Months