company tower banner
SABIC's Specialties Business Company Logo

LNP™ LUBRICOMP™ Compound CX94108

1 of 365 products in this brand
LNP LUBRICOMP CX94108 compound is based on Polystyrene (PS) resin containing proprietary lubricant. Added features of this grade include: Wear Resistant.

Polymer Name: Polystyrene (unspecified)

Processing Methods: Injection Molding

Additives Included: Lubricant (Unspecified), Proprietary

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Chemical Family
Plastics & Elastomers Functions
Technologies

Features & Benefits

Applications & Uses

Plastics & Elastomers Processing Methods

Properties

Mechanical Properties
ValueUnitsTest Method / Conditions
Tensile Stress (Break, 5 mm/min) ¹¹41MPaISO 527
Tensile Strain (Break, 5 mm/min) ¹¹1.8%ISO 527
Tensile Modulus (at 1 mm/min) ¹¹3600MPaISO 527
Flexural Stress (Yield, at 2 mm/min) ¹¹72MPaISO 178
Flexural Stress (Break, 2 mm/min) ¹¹69MPaISO 178
Flexural Modulus (at 2 mm/min) ¹¹3500MPaISO 178
Physical Properties
ValueUnitsTest Method / Conditions
Mold Shrinkage (flow) ᵍ ¹¹0.6 - 0.8%SABIC method
Wear Factor Washer ¹¹36510^-10 in^5-min/ft-lb-hrASTM D3702 Modified: Manual
Dynamic COF ¹¹0.6ASTM D3702 Modified: Manual
Static COF ¹¹0.71ASTM D3702 Modified: Manual
Density ¹¹1.08g/cm³ISO 1183
Thermal Properties
ValueUnitsTest Method / Conditions
Heat Deflection Temperature/Bf (at 0.45 Mpa, Flatw 80*10*4, sp=64mm) ¹¹86°CISO 75/Bf
Heat Deflection Temperature/Af (at 1.8 Mpa, Flatw 80*10*4, sp=64mm) ¹¹80°CISO 75/Af
Impact Properties
ValueUnitsTest Method / Conditions
Izod Impact (Unnotched, 80*10*4, at 23°C) ¹¹10kJ/m²ISO 180/1U
Izod Impact (Notched, 80*10*4, at 23°C) ¹¹2kJ/m²ISO 180/1A
Injection Molding
ValueUnitsTest Method / Conditions
Drying Temperature ⁷80°C
Drying Time ⁷4Hrs
Melt Temperature ⁷250°C
Front - Zone 3 Temperature ⁷265 - 275°C
Middle - Zone 2 Temperature ⁷245 - 255°C
Rear - Zone 1 Temperature ⁷220 - 230°C
Mold Temperature ⁷40 - 65°C
Back Pressure ⁷0.2 - 0.3MPa
Screw Speed ⁷30 - 60rpm
Note
  • ᵍ Measurements made from Laboratory test Coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.
  • ⁷ Injection Molding parameters are only mentioned as general guidelines. These may not apply or may need adjustment in specific situations such as low shot sizes, large part molding, thin wall molding and gas-assist molding.
  • ¹¹ The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.
 

Packaging & Availability

Regional Availability
  • Americas
  • Asia
  • Europe
  • North America