company tower banner
Solera ATO Company Logo

Solera ATO Vy-King 42

Vy-King 42 Insecticide/Nematicide is a water soluble liquid that can be applied by ground, air or chemigation. Vy-King is labeled for use on cotton, peanuts, potatoes and tobacco to control nematodes and many important insect pests. Vy-King 42 Insecticide/Nematicide is mixed with water for application.

Functions: Insecticide, Nematicide

IRAC Code: 1

Application Technique: Aerial Application, Chemigation, Ground Soil Applied

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

IRAC Code
Agrochemical Functions
Technologies
Active Ingredients
Oxamyl: [Methyl N',N'-dimethyl-N-((methylcarbamoyl)oxy)-1-thiooxamimidate] 42.00%
Other Ingredients 58.00%
Total 100.00%

Features & Benefits

Product Information

Vy-King 42 is a water soluble liquid to be diluted with water. For cotton applications, Vy-King 42 may also be mixed with refined vegetable oil.

Use only in commercial and farm plantings; do not use for home or residential uses.

Do not use in Suffolk and Nassau Counties, Long Island, New York.

Do not formulate this product into other end-use products.

Seed piece treatments are prohibited.

All applications to the soil must be incorporated immediately after application to a depth of at least 2 inches by mechanical means or by water. For best results, place Vy-King 42 in the root zone of the plant. If irrigation is used to water in the application, use sufficient water to move the applied Vy-King 42 at least 2 inches deep in the soil. However, do not apply irrigation water such that the water moves off the field.

Applications & Uses

Directions For Use

Restricted Use Pesticide: It is a violation of federal law to use this product in a manner inconsistent with its labeling. Do not apply this product in a way that will contact workers or other persons, either directly or through drift. Only protected handlers may be in the area during application. For any requirements specific to your State or Tribe, consult the agency responsible for pesticide regulation. Pilots must not assist in the mixing and loading operations.

 

Properties

Physical Form

Storage & Handling

Storage and Disposal

Do not contaminate water, food, or feed by storage or disposal.
 

Pesticide Storage: Do not subject to temperatures below 32 degrees F. Store product in original container only, at temperatures of 45 degrees F or higher. Not for use or storage in or around the home. For Emergencies involving a spill, leak, fire, exposure, or accident, contact CHEMTREC at 800-424-9300.
 

Pesticide Disposal: Pesticide wastes are acutely hazardous. Improper disposal of excess pesticide, spray mixture, or rinsate is a violation of Federal Law. If these wastes cannot be disposed of by use according to label instructions, contact your State Pesticide or Environmental Control Agency, or the Hazardous Waste representative at the nearest EPA Regional Office for guidance.
 

Container Handling: Refer to the Net Contents section of this product's labeling for the applicable "Nonrefillable Container" designation.

Nonrefillable Rigid Plastic and Metal Containers (Capacity Equal to or Less Than 5 Gallons): Nonrefillable container. Do not reuse or refill this container. Triple rinse container (or equivalent) promptly after emptying. Triple rinse as follows: Empty the remaining contents into application equipment or a mix tank and drain for 10 seconds after the flow begins to drip. Fill the container 1/4 full with water and recap. Shake for 10 seconds. Pour rinsate into application equipment or a mix tank or store rinsate for later use or disposal. Drain for 10 seconds after the flow begins to drip. Repeat this procedure two more times. Then, for plastic containers, offer for recycling if available or puncture and dispose of in a sanitary landfill, or by incineration. Do not burn unless allowed by state and local ordinances. For metal containers, offer for recycling if available or reconditioning if appropriate, or puncture and dispose of in a sanitary landfill, or by other procedures approved by state and local authorities.

Nonrefillable Rigid Plastic and Metal Containers, (Containers too large to shake (i.e., with capacities more than 5 gallons or 50 pounds)] e.g. Intermediate Bulk Containers [IBC]: Nonrefillable container. Do not reuse or refill this container. Clean container promptly after emptying. Triple Rinse as follows: Empty the remaining contents into application equipment or a mix tank. Fill the container ¼ full with water. Replace and tighten closures. Tip container on its side and roll it back and forth, ensuring at least one complete revolution, for 30 seconds. Stand the container on its end and tip it back and forth several times. Turn the container over onto its other end and tip it back and forth several times. Empty the rinsate into application equipment or a mix tank or store rinsate for later use or disposal. Repeat this procedure two more times. Then offer for recycling if available or puncture and dispose of in a sanitary landfill, or by incineration.