ECP 502.JSF024 is a reducer for use with paint concentrate ECP 502/JSF023 single component nickel/acrylic conductive coating. This enables the correct spray characteristics to be obtained when spray coating to provide effective EMI shielding on plastic housings used in the electronics and computer industries.

Functions: Rheology Modifier, Thinner

End Uses: 1K (1 component) Coating, Conductive Coating

    Knowde Enhanced TDS

    Identification & Functionality

    CASE Ingredients Functions
    Technologies

    Features & Benefits

    CASE Ingredients Features
    Overview
    ECP 502/JSF024 Thinners

    Applications & Uses

    Application Method

    Properties

    Physical Properties
    ValueUnitsTest Method / Conditions
    Boiling Point126°C-
    Density0.871g/cm³-
    Explosion Limits (Lower)1.1vol%-
    Explosion Limits (Upper)7vol%-
    Flash Point25°C-
    Ignition Temperature370°C-
    Solvent Content Organic Solvents100%-
    Vapour Pressure (at 20°C)6.7hpa-
    Product Characteristics
    • The reducer is a mixture of substances, Xylene mix and Butyl Ethanoate.
    • Self-igniting - the product is not self-igniting
    • The danger of explosive - the product is not explosive, possible formation of explosive air and vapor mixtures.

    Regulatory & Compliance

    Certifications & Compliance

    Technical Details & Test Data

    Spray Coating

    ECP 502/JSF024 thinners should be used to dilute the concentrate paint ECP 502/JSF023 to suit local spray conditions. Typically 2 parts of concentrate to 1 part thinners can be used in a conventional gravity feed spray gun or alternatively a pressure pot with an agitator. A gun pressure of 30 psi is recommended. Two passes of the diluted paint are normally required to give the optimum thickness and surface resistivity values.

    Safety & Health

    Precautions

    Highly Flammable: Keep away from sources of ignition - no smoking (S16). Keep away from heat, sparks and open flames. Keep all containers closed when not in use.

    Use under Well Ventilated Conditions:  Do not breathe vapor (S23). Harmful by inhalation (R20). In case of insufficient ventilation wear suitable respiratory equipment (S38) such devices must be used in accordance with the manufacturer's instructions. For excessive vapor, inhalation removes to fresh air and summon medical attention.

    Avoid contact with skin and eyes (S24/25): In case of skin, contact washes with soap and water, dry and apply work cream. Eye contact - flush with water for at least 15 minutes and seek medical attention. If accidentally swallowed summon medical attention.

    Packaging & Availability

    Packaging Type
    Availability

    ECP 502/JSF024 is available in 5-liter cans.