company tower banner
TBA Protective Solutions Company Logo

TBA Protective Solutions ECP 552 EMI Shielding Nickel Acrylic Aerosol

ECP 552 EMI Shielding Nickel Acrylic Aerosol coating combines EMI shielding properties with a convenient method of application for prototype, design and touch-up work; it is specially formulated in order to prevent settling and to provide a homogeneous finish.

Product Type: Coating

Features: Electromagnetic Shielding (EMI)

Application Area: Electrical Components

Application Method: Spray

Chemical Family: Acrylics & Acrylates

    Knowde Enhanced TDS

    Identification & Functionality

    Chemical Family
    Product Type

    Features & Benefits

    Ready-to-Use Product Features
    Overview
    ECP 552 EMI Shielding Nickel Acrylic Aerosol coating combines EMI shielding properties with a convenient method of application for prototype, design and touch-up work; it is specially formulated in order to prevent settling and to provide a homogeneous finish.

    Applications & Uses

    Application Area
    Application Method

    Properties

    Physical Properties
    ValueUnitsTest Method / Conditions
    Aerosol Pressure55 - 60 / 4psi / bar-
    Contents400ml-
    Coverageapprox. 6square feet-
    Drying Time (Full)12hours-
    Drying Time (Touch)15minutes-
    Recommended Dry Film Thickness50 (2)micron (thou)-
    Shelf Life12 Months--
    Surface Resistivity (at 2 thou / 50 microns)0.9ohms/sqASTM D257

    Regulatory & Compliance

    Certifications & Compliance

    Technical Details & Test Data

    Method of Use

    Surface Preparation: All contaminants including mold release, grease and dirt must be removed. Mask areas that do not require spraying.

    Mixing: Shake vigorously for a minimum of 2 minutes to evenly distribute contents. Spray a small area to check compatibility with the substrate.

    Application: Operate in an upright position, spraying in light, even strokes from side to side to avoid flooding. Shake briefly at intervals during spraying. On completion, invert the aerosol and spray to clear the valve and nozzle. It is advised to clear any excess material from the nozzle at frequent intervals to prevent blockage. If the nozzle blocks, use a pin to clear the opening, or remove the nozzle and flush with Toluene, Xylene or MEK. Replace the nozzle taking care to point the opening away from you. Optimum shielding performance is normally achieved at 3 coats. It is advised to coat several thinner coats than try to coat heavily in one pass.

    Safety & Health

    Precautions
    • Pressurized container. Protect from sunlight and do not expose to temperature exceeding 50oC. Do not pierce or burn, even after use. Do not spray on an open flame or any incandescent material. Keep away from sources of ignition - No smoking.
    • Use under well ventilated conditions: Contains nickel / xylene mix / toluene. Harmful by inhalation. Do not breathe vapor. In case of insufficient ventilation - wear suitable respiratory equipment, which must be used in accordance with the manufacturer’s instructions. For excessive vapor inhalation, remove to fresh air and summon medical attention.
    • Avoid contact with skin and eyes: In case of skin contact, wash with soap and water, dry and apply work cream. Eye Contact - flush with water for at least 15 minutes and seek medical attention. If accidentally swallowed, summon medical attention.