ReVue™ CRM is a high-quality repair mortar. It is simple to work with and can be used for both interior and exterior applications.

Product Type: Mortar

Application Area: Masonry

Features: Ease of Handling, Fast Curing, Freeze/Thaw Stability, Good Bonding Strength, High Performance, High Strength, High Temperature Resistance, Wide Temperature Operating Range

Application Method: Trowel

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Product Type

Features & Benefits

Labeling Claims
Advantages
  • Fast curing. ReVue-CRM is open to standard traffic within 4 hours of application and can be applied as thin as ¼”.
  • High strength
  • Interior and exterior applications
  • One component
  • Gains strength quickly
  • Compatible with a wide range of temperatures
  • Superior bond
  • Better coverage
  • Resistant to freeze and thaw conditions
  • No VOC (0 g/L).

Applications & Uses

Application Area
Application Method
Compatible Substrates & Surfaces
Uses

Ideal for use in the following applications: warehouses, vertical repairs, truck docks, heavy industrial repairs, commercial floors and ramps. With its capability to withstand extreme temperatures, ReVue-CRM is ideal for fast track projects in high traffic areas including streets and truck docks.

Limitations

Do Not Use:
1. Where hydrostatic pressure (water) exists or moisture emissions exceed level permitted for installing floor covering.
2. Over presswood, particle board, Masonite, chipboard, OSB, underlayment board not of APA Underlayment (exterior) grade or similar dimensionally unstable materials susceptible to movement or swelling.
3. Over gypsum based patches or underlayment material due to chemical reaction.
4. Single layer stripwood floors.

Application Equipment
Protective clothing
Trowel (stainless steel), 4" x 12" (101.6 x 304.8 mm) Pool Trowel or 3” x 12” (76.2 x 304.8 mm) finishing trowels
Mortar mixer – [Baugh, Imer or Kol mixer]
 

 

Assemble Equipment: Due To The Limited Pot Life Of The Material, All Application Equipment, Etc. Should Be Ready For Immediate Use. (Clean Roller With Tape To Remove Any Residual Lint.)

 

Cleanup: Use Water To Clean Revue-crm From Tools And Equipment. Once It Is Dry It Will Need To Be Removed Mechanically. It Is Important To Periodically Clean Tools.

Surface Preparation

The concrete surface should be clean and sound. The surface should be free of any bond breakers including but not limited to loose gravel, oil, wax, grease or dirt. Concrete with cap intact that is being overlayed to change slope, etc. needs to be aggressively blasted with shot or scarified. The concrete should be presoaked and saturated surface-dry SSD condition without standing water.

Applications

Coverage Rate:
Coverage Rate Will Depend Upon Application Thickness. A One Bag Mix Will Nominally Cover (Finished Floor):
Revue-crm: 9.6 Ft2 @ 1/2" (0.89 M2 @ 12.7 Mm)
Note: Do Not Apply Less Than ¼” In Thickness Or Where Featheredge Is Needed.
Pour One-half Gallon Of Water Into The Mortar Mixer. Begin Mixing.
While Mixing Slowly Add One Bag (55 Lbs) Of Concrete Repair Mortar Over 3-5 Minutes To The Water In The Mortar Mixer. Note: For Deeper Patches (>1”), Revue-crm May Be Extended By Adding Up To 30 Pounds Of Clean Pea Gravel. A Small Amount Of Additional Water May Be Added Only After 2 Minutes Of Mixing; No More Than One Cup.
Do Not Over Mix Due To The Formation Of Air Bubbles.
Working Time: Approximately 20 Minutes At 72°f (22.2°c).
Pour The Mixed Material On The Prepared Area.
Use Hand Trowels To Compact And Level Material. Firmly Work The Material Into The Bottom Ensuring A Good Bond.
Set Time Of Material Is 30-45 Minutes.
Allow Material To Cure 4 Hours Before Opening To Traffic.

Applications of Additional Coatings

The repair mortar needs to be mechanically prepped, or coatings will not adhere well. The repair mortar needs to cure >12 hours before it will be hard enough; this will vary with cure conditions.

Properties

Typical Properties
ValueUnitsTest Method / Conditions
Direct Shear Bond (1 Day)155.0psi
Direct Shear Bond (28 Day)445.0psi
Direct Shear Bond (7 Day)380.0psi
Freeze & Thaw Resistance (RDM)97.0%
Open to Traffic4.0hours
Rapid Chloride Permeability (Low)1050.0
Set Time30 - 45 minutes
Slant Shear Bond (1 Day)1900.0psi
Slant Shear Bond (28 Day)3300.0psi
Slant Shear Bond (7 Day)2900.0psi
Strength (1 Day)4500.0psi
Strength (28 Day)7000.0psi
Strength (3Hours)1200.0
Strength (7 Day)6000.0psi
Volatile Organic Compound (VOC)0 (0.0)ASTM D3960
Working Time20.0minutes

Regulatory & Compliance

Certification

LEED® CREDIT – LEED Green Building Certification Program credits may be available:

Indoor Environmental Quality
- 4.2 Low-Emitting Materials, Paint & Coatings
- Material and Resource
- 4.1 / 4.2 Recycled Content, 10% / 20%

Safety & Health

Preliminary Floor Inspections

Check The Temperature: Floor Temperature And Materials Need To Be Above 50-90°f (10-32° C). Note: Higher Temperature Application Will Yield Shorter Work Times.
Check The Concrete: Concrete Must Be Structurally Sound. Tennant Assumes No Liability For Substrate Defects. If You Suspect The Concrete Has Been Sealed Or Coated, Call Tennant Company Tech Support For Further Instructions.
Check For Moisture: Concrete Must Be 28 Days Old Before Application Of This Material. Concrete Moisture Testing Must Occur. In-situ Relative Humidity Testing Is Recommended. Readings Must Be Below 75% Relative Internal Concrete Humidity. Test Methods Can Be Purchased At Www.astm.org, See F2170, Or Follow Manufacturer's Instructions. If Moisture Issues Are Present, The Use Of A Moisture Mitigation System May Be A Consideration. Please Call Tennant Company Technical Support For Further Information / Instructions.

Packaging & Availability

Packaging Type
Application Characteristics
Thickness
¼” to 4”(6.35 mm to 101.6 mm)
Coverage Rate per bag mix
9.6 ft2 @ ½” (0.89 m2 @ 12.7 mm)
Packaging Options/ Part Numbers

ReVue-CRM
9013209 (Pallet of 48 - 50 lb. doublé-wall bags)
Note: Mix with exactly ½ gallon (1.89 liters) of potable wáter. DO NOT OVER WATER.

Storage & Handling

Storage

Materials should be stored indoors between 65ºF (18ºC) and 90ºF (32ºC).

Shelf Life

One year from date of manufacture.

Disposal

Dispose of all excess material, packaging and other waste in accordance with federal, state and local regulations.