Knowde Enhanced TDS
Identification & Functionality
- Product Type
- Type
- Proprietary emulsion polymer
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Product Highlights
- VOC-compliant
- Quick grab
- Nonflammable
- No offensive odor
- Cleans easily with water in wet state
- Achieves NFPA Class A fire rating
Applications & Uses
- Markets
- Applications
- Application Area
- Application Method
- Compatible Substrates & Surfaces
- Recommended For
Installing FRP (fiber-reinforced plastic), plastic laminate, wainscoting and other wall coverings over many common porous surfaces.
- Compatible Materials
FRP to many common porous building materials including unprimed/unpainted drywall, tile board, fiber cement backer board, wood and non-treated plywood.
- Directions
Preparation
Surfaces must be dry and free of any material that may deter adhesion, including severe and thick amounts of drywall joint compound. Patch holes and depressions and remove any bumps or high spots, dust, oil, and grease. Concrete surfaces must be well cured and completely dry.
Application
Cut and pre-fit all panels. Lay fiberglass panels flat and let them acclimate to room temperature 24 hours before installing. Note: do not use when temperature, adhesive or materials are below 50°f. Spread adhesive over entire back of panel, using a v-notch trowel with notches 3/16” wide x 1/4” deep and spaced 1/2” center to center.
Keep trowel notches clean and free of adhesive build-up to ensure proper application. Immediately place panel against surface and press firmly over entire surface, working from the edge of the panel where molding is installed outwards to the open edge. Using a roller over the entire installed wall panel is also recommended. Note: Bracing may be required if walls or panels are not flat. Panels used in conjunction with channel moldings should NOT fit tightly into the moldings. Leave a small area in the molding for expansion and follow panel manufacturer’s recommendations. Any holes drilled through the FRP for fasteners, pipes or conduits should be oversized to allow for natural movement of the panel. When installing FRP panels over below grade concrete or block walls where moisture can penetrate from the back, attach furring strips with mechanical fasteners and Titebond Fast Set Polyurethane or Titebond Heavy Duty Construction Adhesive and then adhere a solid backing to the furring strips. Spread no more adhesive than can be installed in 20 minutes or less.
Cleanup
Tools and adhesive may be cleaned with water while the adhesive is wet. If dried, tools and adhesive may be cleaned with water/acetone/vinegar mixture. Follow solvent vendor’s precautions.
Properties
- Color
- Physical Properties
- Technical Data
Value | Units | Test Method / Conditions | |
Solids | 67.0 | % | - |
Viscosity | 100000.0 | cps | - |
pH | 5.0 | - | - |
VOC | max. 50 | g/L | - |
Flash Point | min. 200 | °F | - |
Freeze/Thaw Stability | Stable | - | - |
Value | Units | Test Method / Conditions | |
Application Temperature (Adhesive and Substrates) | 50 to 90 | °F | - |
Service Temperature | 0 to 110 | °F | - |
Coverage | 50.0 | sq. ft. per gallon | - |
Working Time (70°F) | 20.0 | minutes | - |
Regulatory & Compliance
- Certifications & Compliance
- Specifications & Certifications
Meets LEED v4.1, SCAQMD, CARB and NAHB Green Building specifications. FDA and Canadian Food Inspection Agency (CFIA) approved for indirect food contact. Exceeds the performance requirements of ASTM C557 and ASTM E84 Class A Fire Rating.
Technical Details & Test Data
- User Tips
Do not bond two non-porous substrates together such as FRP, metal, plastic, foam board, sealed concrete, fiberglass face, or mold-resistant or painted gypsum wallboard, or any other non-porous surfaces. For installations bonding two non-porous substrates together use Titebond Ultimate Advanced Polymer Panel Adhesive. For installations over treated plywood use Titebond Solvent Based FRP Adhesive or Titebond Ultimate Advanced Polymer Panel Adhesive. The optimal trowel for best overall performance and coverage is a v-notch trowel, 3/16” wide x 1/4” deep, spaced 1/2” c.c. Trowels using dimensions other than the optimal size can be used, but they may affect working time and coverage.
Packaging & Availability
- Packaging Type
- Packaging Size
Size Part Number UPC Case UPC Units Per Package Weight Packages Per Pallet
4 Gallon Pail 4054 37083040548 NA 1 50.58 lbs. 36
Storage & Handling
- Storage Life
Up to 2 years in unopened container stored above 50°F.