- Excellent primer for use with topcoats containing Strong solvents, ex: urethanes, epoxies, vinyls
- Moisture and chemical resistan
- Contains no lead or chromate
- Economical cost per square foot ratio
Applications & Uses
- Markets
- Applications
- Application Method
- Compatible Substrates & Surfaces
- Uses
Tripoxy Primer is recommended for maintenance applications on iron, steel, galvanized, and aluminum substrates. Uses include:
- Exterior structures, ferrous and nonferrous
- Bridges
- Power line towers
- Microwave towers
- Metal buildings
- Structural steel components
- Large fabricated structures
- Limitations
- Substrate temperatures must be above 45° F
- Requires adequate ventilation in confined spaces
- Not for use in submersion applications
- Must be topcoated and protected from UV exposure
- Application Data
Surface Preparation:
All surfaces must be clean, dry, and free of contaminants. All dirt, grease, rust, mill scale, or loose chalky paint must be removed in conformance with the provisions in section 59-2,”Painting Structural Steel’, or Section 59-3, “Painting Galvanized Surfaces’ of the State of California Department of Transportation Standard Specifications unless otherwise specified in the contract special provisions.The retrieval and analysis ofsoluble salts on substrates shall
be conducted in accordance with “SSPC: The Society for Protective Coatings,” rule. The substrate mustbe cleaned so that the maximum level of soluble salts does not exceed 10 micrograms per square centimeter. Areas should be tested at the rate of 3 tests for the first 1000 square feet prepared per day, and one test for each additional 1000 square feet or portion thereof, at randomly selected locations.
When less than 1000 square feet of surface area is prepared in a shift, at least 2 tests should be performed. lf levels of soluble salts exceed the maximum, the entire area represented by the test should be cleaned again and tested until soluble salt levels conform to this requirement.
Unpainted new structural steel: Blast clean near white with appropriate abrasive media. Allsurfaces mustbe clean, dry, and free of contaminants. Apply appropriate primer to the recommended ary film thickness. ° SSPC-SP1S * SSPC-SP10
Previously painted structural steel: Steam clean or power wash to remove all dirt, grease, contaminants, and gloss from existing paint. Spot clean rusty areas to remove all rust and mill scale.- SSPC-SP1 * SSPC-SP6
- SSPC-SP2 ¢ SSPC-SP11
- SSPC-SP3
Galvanized steel: Steam clean or power wash to remove all dirt, grease, and contaminants. Spot clean to remove rust and mill scale. Roughen surface by whip blasting or light sanding. Do not remove intact galvanizing.
- SSPC-SP1 * SSPC-SP7
- SSPC-SP2 ¢ SSPC-SP11
- SSPC-SP3
Note: Blast cleaned surfaces must be primed the same day blast cleaning is done.
- Mixing Parametres
Ratio: Part A :Part B
By Weight 1:1
By Volume 1:1
Sweat-in Time: 30mins
- Applications
Tripoxy Primer can be applied by HVLP, air assist airless, brush or roller.
HVLP:
Fluid Tip and Needle: 050"
Fluid Pressure: 8 - 10 psi
Air Cap Pressure: 60 psi
Air Assist Airless:
Fluid Tip: 015"
Fluid Pressure: 800 - 900 psi
Air Cap Pressure: 10 - 15 psi
Thinning :xylene, oxsol, or acetone
CleanUp :xylene, oxsol, or acetone
Properties
- Properties
REQUIRED FILM THICKNESS: ASTM D1005 Minimum Dried Film 2-3 mils ASTM D4414 Minimum Wet Film 3.7-5.6 mils ASTM D523 GLOSS: @ 60° 44849 @ 20° N/A ASTM D3363 PENCIL HARDNESS: H Pass ASTM D5402 MEK RUBS: 50 Double Pass ASTM D2794 IMPACT RESISTANCE: 60 inlb forward, 40 inlb reverse Pass ASTM B117 SALT SPRAY RESISTANCE: 5% Salt Spray, 300 hours Pass ASTM D5894UV CORROSION WEATHERING: ASTM D610 Rusting 7 cycles, 300 hours Pass ASTM D714 Blistering 7 cycles, 300 hours Pass ASTM D4587/D523/D4214 QUV-UVA 500 hours @ 60° N/A 1000 hours @ 60° N/A ASTM D2247/D714 HUMIDITY RESISTANCE: 800 hours Pass ASTM D4585 MOISTURE CONDENSATION: 100° F, 800 hours Pass ASTM D3359 ADHESION: 5B Pass ASTM D4060 ABRASION RESISTANCE: CS17 wheel, 200 cycles, 1 kg load Pass ASTM D522 FLEXIBILITY: 180° bend, 1/8” mandrel Pass ASTM D3170 CHIP RESISTANCE: Rating N/A ASTM D2485 DRY HEAT RESISTANCE: N/A N/A ASTM D2243 WATER-BORNE FREEZE THAW: 3 cycles N/A
Technical Details & Test Data
- Dry Schedule
DRY SCHEDULE: [at 50% RH and 2.0 mils DFT] 60° F 77° F 90° F Dry to Touch 60 mins 30 mins 20 mins Recoat 8 hrs 4 hrs 2 hrs Dry to Handle 24 hrs 8 hrs 4 hrs Full Cure 7 days 7 days 7 days Critical Recoat Window: After two weeks power wash or mechanically abrade all surfaces.- Coverage
Theoretical at1.0 mil DFT: 866 sq fi/gal
Theoretical at 2.0 mils DFT: 433 sq f/gal
Safety & Health
- Health and Safety
Warning:
FLAMMABLE LIQUID AND VAPOR. May be harmful if swallowed or inhaled. Vapor may affect the brain or nervous system causing dizziness, headache, or nausea and can cause nose and throat irritation. Keep away from sparks, heat, or open flames. Use with adequate ventilation. Avoid breathing of vapor. Avoid contactwith eyes, skin, andclothing. Wash hands thoroughly after using and before eating and smoking. Wear an appropriate, properly fitted respirator (NIOSH/MSHA approved) during and after application unless air monitoring demonstrates vapor levels are below applicable limits. Follow respirator manufacturer’s directions for use. Keep container closed when not in use. If spillage occurs, absorband dispose ofaccordintgo local regulations.
Notice:
Intentional misuse by deliberately concentrating and inhaling the contents may be harmfulor fatal. Reports have associated repeated and prolonged occupational overexposure to solvents with permanentbrain and nervous system damage.
First Aid:
Should eye contact occur, flush with plenty of water for at least 15 minutes and get medical attention if vision is disturbed. For skin, wash thoroughly with soap and water. If swallowed, seek medical attention immediately. DO NOT induce vomiting.
KEEP THIS PRODUCT OUT OF THE REACH OF CHILDREN.
Packaging & Availability
- Color Availability
Tripoxy Primer is stocked in medium yellow.
- Packaging
Part A:
- 1 gallon cans
- 5 gallon pails
Part B:
- 1 gallon cans
- 5 gallon pails
- Order Code
Part A: 941P309
Part B: 941B
Individual products are identified by the product series number, followed by an identifier and color number.
Storage & Handling
- Pot Life
ASTM D2196 Pot Life: [valid for qtys of 1 gallon or more]
50°F 60° F 77°F 85° F 4 hrs 4 hrs 4 hrs 3 hrs - Shipping and Handling
SHIPPING DESCRIPTION: [CFR 49] Ground, Air, Vessel Paint, 3, UN1263, PG IIRequired Label FLAMMABLE LIQUIDRequired Marking PAINT UN1263 IMDG PACKAGING: FLAMMABLE LIQUID, class 3.2, UN1263, II IMDG STOWAGE: Category B UNIFORM FIRE CODE: [CFR 29] CLASS I-B STORAGE TEMPERATURE: 120° F max SHELF LIFE: [warranted] 1 YEAR HMIS RATINGS: H - 2; F - 3; R - 0; PP - H