company tower banner
Trimite Company Logo

Trimafloor 2504

1 of 6 products in this brand
Trimafloor 2504 is a water based acrylic, single pack, clear floor sealer.

Product Type: 1K (1 component) Coating, Sealer, Waterborne Coating

Features: Abrasion Resistant, Excellent Stain Resistance

Compatible Substrates & Surfaces: Concrete, Painted Surfaces, Stone, Wood

Application Method: Brush, Roller

Chemical Family: Acrylics & Acrylates

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Chemical Family

Features & Benefits

Features
  • Can be used on concrete, stone and brick floors.
  • Use as a dust sealer.
  • Good abrasion and staining resistance.
  • Suitable for foot and light-to-medium traffic areas.
  • Clear sealer for concrete floors
  • No mixing
  • Water-based, very low odor
  • Minimizes dusting and dirt pick-up.

Applications & Uses

Application Method
Compatible Substrates & Surfaces
Surface Preperation

All surfaces to be coated should be dry and cleaned as necessary to remove all contamination.
Concrete:

  • Do not apply to newly laid concrete. Concrete surfaces to be coated should be at least 4 weeks old and have a moisture content of less than 7%.
  • It is recommended for optimum coating lifetime that laitance is removed before painting, by (ideally) vacuum blast cleaning (to produce a profile suitable for the coating thickness to be applied); grinding; or acid etching (to produce an open, granular surface). If acid etching, thoroughly wash down and allow to completely dry before coating.
  • Smooth, power-floated concrete surfaces do not provide good adhesion for painting, with coatings likely to detach after short periods. Smooth surfaces should ideally be treated as above, for laitance removal, to provide a good key for painting.
Application Details
  • Designed for application by brush, roller or squeegee.
  • On bare concrete, thin the first coat by up to 10% to act as a sealer, before applying a full, unthinned coat.
  • Excessively thick coatings will dry to a milky white appearance and are prone to softening when wet. The performance of the sealer is adversely affected by the application of excessively thick coatings. Two thin coats are better than one thick application.
Mixing

Thoroughly stir the coating before use. A power mixer is highly recommended. A widebladed stirrer is essential for adequate mixing if only hand stirring. Stir occasionally during use to maintain a homogenous mix.

Thinner/Cleaner

Clean water.

Application Conditions

Throughout the application and the drying/curing time of coatings: (a) good ventilation isrequired; (b) do not apply when damp weather conditions are likely; (c) the substrate temperature should be at least 3ºCabove the Dew Point; and (d) the RH (Relative Humidity) should be below 85%. Do not apply the product when the ambient temperature falls below 10ºC. The paint temperature at the time of application should ideally be 15ºC- 20ºC.

Properties

Finish
Clear
Typical Properties
ValueUnitsTest Method / Conditions
Flash Point23 - 60ºC-
Specific Gravity1.00 ± 0.1kg/l-
VOC Contentmax. 70g/l-
Volume Solids (may vary with colour)18 ± 2%-
Film Thickness and Coverage
Rec. Typical Dry Wet Theo. Coverage
30 µm 167 µm 6 m2/l

Actual coverage varies considerably with factors including surface porosity, roughness, application methods and conditions

Regulatory & Compliance

Compliance

2004/42/EC (2012)* sub-category (i) - VOC level below 140 g/l.

Technical Details & Test Data

Drying & Overcoating Times (at Rec. Min DFT)
10°C 20°C 30°C
Surface Dry 1h 30m 20m
Hard Dry 2h 1h 30m
Overcoat Min 36 h 24h 12h
Overcoat Max Indefinite Indefinite Indefinite

Drying and overcoating times can be greatly affected by method and conditions of application such as thickness applied, temperature, ventilation etc. Data above are given as a guide.

Note

  • Foot traffic can be allowed on the coated area after 24 hours, and heavier traffic after 72 hours at 20oC.
  • Concrete floors are always several degrees colder than the ambient temperature, and on cold days, drying times will be extended.
  • Keep coated areas dry for a minimum of 24 hours following application. Slow drying is usually attributable to either low temperatures, or the application of excessively thick coats of paint.

Storage & Handling

Shelf Life

Minimum of 2 year from date of manufacture when correctly stored in unopened containers.

Storage

The product should be stored in cool, dry, frost-free conditions, in sealed containers. Most paint materials will apply optimally when at 15ºC- 20ºC.