- Product Characteristics
- Corrosion inhibition in aqueous systems at pH 7 – 10
- Corrosion protection in aerosol cans
- Non-foaming
- Hard water stability
- Biodegradable
- Non-phenolic
- Approved for use as inerts in non-food pesticide formulations
- Not recommended for use in acid systems
Applications & Uses
- Markets
- Applications
- Home Care Applications
- I&I Cleaning Applications
- Recommended Uses
- Synthetic coolants & cutting fluids for ferrous and non-ferrous metals
- Cooling tower additive
- Corrosion inhibitor for down-hole drilling
- Corrosion inhibitors for radiator fluids
- Corrosion inhibitors for aerosol cans
- Corrosion inhibitors for aqueous paints and coatings
- Metal working fluids
Properties
- Appearance
- Clear to hazy viscous liquid
- Typical Properties
Value | Units | Test Method / Conditions | |
Active Content | 100 | % | — |
Alkali Value | max. 570-600 | mgKOH/g | — |
Color | max. 2 | Gardner | — |
Density (25°C) | 1.15 | g/ml | — |
pH Value (1% in Distilled Water) | 9.3 - 10.3 | — | — |
Technical Details & Test Data
- Product Efficacy Studies
-
Metal Panel Submersion Test
DeCORE BE and DeCORE BE-85 were tested at 0.5% by weight in hard water and/or distilled water on cold rolled steel panels, in closed glass jars at room temperature for six months.
The bottom half of the metal panels were submerged in the test solutions. The top half of the panels were exposed to the vapor phase. Panels on the left did not contain inhibitor
-
Corrosion Testing in Aerosol Cans
Tin plate (lined and unlined) aerosol cans were partially filled with solutions of DeCORE BE at 0.5% by weight in hard water (100 ppm as CaCO3 & 71 ppm as chloride). The cans were covered and stored at room temperature for 5 months and observed for corrosion.
-