Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Polymer Name
- Technologies
- Product Families
Features & Benefits
Applications & Uses
- Markets
Properties
- Color
- Flame Rating
- Mechanical Properties
- Typical Properties
- Thermal Properties
- Electrical Properties
- Flammability
Value | Units | Test Method / Conditions | |
Tensile Strength at Yield (Sample Type 1B, 50mm/min) | 60 - 70 | MPa | ISO 527-1/2;1993 |
E-modulus (Sample Type 1B, 50mm/min) | 3100 - 3400 | MPa | ISO 527-1/2:1993 |
Elongation at Break (Sample Type 1B, 50mm/min) | max. 10 | % | ISO 527-1/2:1993 |
Compressive Strength (Sample Type B, 5mm/min) | 115 - 125 | MPa | ISO 604:2002 |
Compressive Modulus (Sample Type A, 1mm/min) | 2300 - 2700 | MPa | ISO 604:2002 |
Flexural Strength (1.5mm/min) | 92 - 95 | MPa | ISO 178:2001 |
Flexural Modulus (1.5mm/min) | 2300 - 2600 | MPa | ISO 178:2001 |
Izod Impact Strength (Sample Type A, notched) | 13.9 | kJ/mm² | ISO 180:2000 |
Dynamic Coefficient of Friction (31.4m/min, 1.75MPa) | 0.195 | — | — |
Limiting PV | 100.0 | MPa/m | — |
K-Factor (Wear Factor, 31.4m/min, 1.75MPa) | 3.5x10⁻⁵ | mm³/Nm | — |
Value | Units | Test Method / Conditions | |
Density (Test Method A) | 1.11 | g/cm³ | ISO 1183:1997 |
Moisture Absorption (Equilibrium, 50% RH, 23°C) | 1.7 | % | ISO 62:1999(modified) |
Water Absorption (24 hrs, Immersion at 23°C) | 0.18 | % | ISO 62:1999 (modified) |
Water Absorption (24 hrs Saturation, Immersion at 23°C) | 5.3 | % | ISO 62:1999 |
Value | Units | Test Method / Conditions | |
Melting Temperature (Tg) | 219.5 | °C | — |
Glass Transition Temperature | 60.0 | °C | ISO 11359:1999 |
Heat Deflection Temperature (HDT/A, 1.80MPa) | 72.0 | °C | ISO 75 |
Maximum/Minimum Continuous Service Temperatures | 100/-40 | °C | — |
Maximum/Minimum Intermittent Service Temperatures | 150/-100 | °C | — |
Coefficient of Linear Thermal Expansion (23 - 55°C) | 5 - 8x10⁻⁵ | °C⁻¹ | ISO 11359-2:1999 |
Thermal Conductivity (Mean T = 20°C) | 0.26 | W/m°C | ISO 8301:1991 |
Value | Units | Test Method / Conditions | |
Dielectric Constant (1 Hz) | 3.7 | — | IEC 60250:1969-01 |
Dielectric Constant (100 Hz) | 4.0 | — | IEC 60250:1969-01 |
Dissipation Factor (100 Hz) | 0.09 | — | IEC 60250:1969-01 |
Dielectric Strength | 25.0 | kV/m | IEC 60243:-1:1998-01 |
Volume Resistivity | min. 1x10¹³ | ohm.m | IEC 60093:1980-01 |
Surface Resistivity | min. 1x10¹² | ohm.m | IEC 60093:1980-01 |
Comparative Tracking Index | 600.0 | CTI | IEC 60112:2003-01 |
Value | Units | Test Method / Conditions | |
Flammability | HB | — | IEC 60695-11-10:2003-08 |
Packaging & Availability
- Availability
Rod 10mm-500mm DIA Tube 50mm-1000mm OD Plate 6mm-100mm THICKNESS Cut to size Available upon request