company tower banner
Wilsonart Company Logo

Wilsonart® 3034 Postform Edge PVA Adhesive

1 of 15 products in this brand
Wilsonart® 3034 Postform Edge PVA Adhesive is an emulsion of water and polyvinyl acetate for high-speed postformed edge applications.

Product Type: Adhesive, Laminating Adhesive

Application Area: Laminates

Application Method: Roller, Spray

Chemical Family: Polyvinyl Acetates (PVA)

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Primary Contents

Vinyl acetate homopolymer (CAS 9003207), Water (CAS 7732185), NJTSRN #950002

Features & Benefits

Ready-to-Use Product Features
Product Highlights
  • Glue spreader or spray application (glue spreader/hot press applications); suitable for postforming applications
  • Glows with blacklight for easier viewing and removal of excess adhesive
  • Professional use only
  • Does NOT require stirring before use

Applications & Uses

Application Area
Application Method
Applications To Avoid
  • Tempered hardboard products
  • Fire retardant treated board products
  • Boards treated to be moisture resistant
  • Low pressure melamine surfaces
  • Metallic, polyester and painted surfaces
General Instructions

General Use Instructions

  • Use only after you read and understand the warnings, safety measures and first aid instructions printed on container.
  • May be applied by spray or glue spreader.
  • Ensure substrates and adhesive are above 65 ̊F.
  • Best results are achieved between 70 ̊F and 85 ̊F.
  • Surfaces must be clean and dry.

Continuous Panel Lamination/Postforming Instructions

  • Roll coat 6-8 wet mils onto substrate.
  • Open time is a brief 2 - 5 minutes.
  • Index and insert assembly into laminator.
  • Spray no-drip portions of the core after it exits the glue spreader.
  • Exit surface temperature should be 150 ̊F-160 ̊F.
  • For postforming, spray edge to be formed before insertion into postformer with 100% coverage.
  • Over-coverage of formed edge will prevent postforming.
  • Allow adhesive to dry before compression force is applied.
  • Laminate postforming temperature must be 325 ̊F-375 ̊F.

Spray Equipment Recommendations

  • Binks: Gun: M95, M95 Auto, M61; Fluid Tip: 66ss (edge/underwrap); Air Cap: 66R or 66PB (edge/underwrap); 68PB (overhead).
  • DeVilbiss: Gun: JGA 510; Fluid Tip: D; Air Cap: 64HD

Flow-Through Postforming Instructions

  • For Midwest or comparable equipment.
  • Coat 100% of both surfaces uniformly with 7-8 wet grams/ft2. The edge to be formed must receive 100% coverage. Open time is 2-5 minutes.
  • Adjust oven temperature to raise laminate exit temperature to 125 ̊F-150 ̊F.
  • Put laminate and core through the oven. Adhesive appearance should be approximately 50% clear with no wet spots on edge to be postformed. Adhesive should initially feel dry, but still smear with increased finger pressure.
  • Index the laminate and core and pinch roll immediately at 30 psi minimum.Do not pinch roll at temperatures under 110 ̊F.
  • Postforming may now proceed.
  • For best results, 180 ̊ wraps should end on at least 3/4” of flat surface.

Glue Spreader/Hot Press Instructions

  • Follow the glue spreader manufacturer’s recommendations.
  • Use a dual durometer roller (Black Bros. A2158, 16 x 1⁄2” pattern).
  • Select a groove pattern appropriate for PVA adhesive.
  • Apply 6-8 wet mils with glue spreader.
  • Open time is 2-5 minutes.
  • Assemble and hot press for 1-2 minutes under 40-50 psi and 180 ̊F-200 ̊F.
  • Allow panel to cool for 2-5 minutes. Proceed with fabrication.

Properties

Color
Physical Properties
ValueUnitsTest Method / Conditions
Viscosity2100 - 3100cps-
Density9.1lbs/gal-
Solids Content53 - 57%-
pH4.5 - 5.5--
Voc Contentmax. 20grams/literMethod 24
Vhap Contentmax. 0.02lbs/lbs solids-
Coverage (Spreader, 7 Wet Mils)approx. 229ft² /gallon-
Coverage (Spray, Bonded)approx. 295ft² /gallon-
Hot Press Time (40 To 50Psi)1 - 2minutes-
Open Time2 - 5minutes-

Regulatory & Compliance

Regulatory & Compliance
  • GREENGUARD® Certified
  • Complies with SCAQMD, Rule 1168
  • Complies with the Ozone Transport Commission (OTC)
  • Qualifies for LEED®-NC & CI EQ Credit 3.2: Construction Indoor Air Quality Management Plan-Before Occupancy
  • Qualifies for LEED®-NC & CI EQ Credit 4.1: Low Emitting Materials: Adhesives & Sealants
  • Qualifies for LEED®-NC & CI EQ Credit 4.4: Laminating adhesives shall contain no added urea-formaldehyde resins.

Packaging & Availability

Availability

5-gallon pails, 55-gallon drums and 275-gallon totes (returnable)

Storage & Handling

Storage
  • Do not allow to freeze. 
  • Close container tightly when not in use and store off the floor in a well ventilated area. Rotate stock.
Shelf Life

Shelf life expires 1 year from manufacture date.

Clean Up/Disposal
  • Clean with hot tap water while adhesive is wet.
  • Removal of dried adhesive is very difficult. Use diluted ammonia to clean dry adhesive.
  • Wash water is RCRA non-hazardous.
  • Dispose of in accordance with regulations.