company tower banner
Addiplast Group Company Logo

Addiflam® A2 I G10 V20

1 of 69 products in this brand

Polymer Name: Polyamide 66 (PA 66)

Fillers Included: Glass Fiber

Additives Included: Flame Retardant

    Knowde Enhanced TDS

    Identification & Functionality

    Additives Included
    Chemical Family
    Fillers Included
    Technologies

    Features & Benefits

    Fire Resistance
    Halogen and antimony free

    Applications & Uses

    Properties

    Flame Rating
    Mechanical Properties
    ValueUnitsTest Method / Conditions
    Charpy Notched Impact Strength (cond)9kJ/m2ISO 179-1/1eA
    Hardness (Cond)86Shore DISO 868
    Charpy Notched Impact Strength (dam)6.5kJ/m2ISO 179-1/1eA
    Hardness (Dam)89Shore DISO 868
    Charpy Unnotched Impact Strength (cond)50kJ/m2ISO 179-1/1eU
    Charpy Unnotched Impact Strength (dam)48kJ/m2ISO 179-1/1eU
    Elongation at Break (cond)6%ISO 527-2/1A
    Elongation at Break (dam)4%ISO 527-2/1A
    Flexural Modulus (cond)4700MPaISO 178
    Flexural Modulus (dam)8000MPaISO 178
    Izod Notched Impact Strength (cond)9kJ/m2ISO 180/1A
    Izod Notched Impact Strength (dam)6kJ/m2ISO 180/1A
    Stress at Break (cond)70MPaISO 527-2/1A
    Stress at Break (dam)115MPaISO 527-2/1A
    Stress at Yield Point (cond)70MPaISO 527-2/1A
    Thermal Properties
    ValueUnitsTest Method / Conditions
    Melting Point260°CISO 11357-3
    Electrical Properties
    ValueUnitsTest Method / Conditions
    CTI450VCEI 60112
    Physico-Chemical Properties
    ValueUnitsTest Method / Conditions
    Density1.34g/cm3ISO 1183-1
    Fire Resistance
    ValueUnitsTest Method / Conditions
    Incandescent Glow Wire Flammability Test (2mm)960°CCEI 60695-2-12
    Limit Oxygen Index31%ISO 4589-2
    Vertical Burning (at 1.6mm)V0Test 50W Ul94

    Regulatory & Compliance

    Certifications & Compliance

    Technical Details & Test Data

    Note
      The values indicated above have been realized with standard specimens in room temperature, except if particular conditions:
    • dam: specimens 48h after molding
    • cond: specimens conditioned according to ISO 291 et ISO 1110.
    • These datas must be considered as indicative values, but in no case as minimum values. Moreover, the design of the mold/die, the processing conditions and the color may have an impact on the properties. The information given herein is the outcome of our research and experience. It is given in all good faith but can neither be interpreted as a warranty given by us nor incur our liability especially in the event of infringement of third party rights.