company tower banner
Addiplast Group Company Logo

Addiflam® MEI 52046 X

1 of 69 products in this brand

Polymer Name: Polypropylene Copolymer

Additives Included: Flame Retardant

Fillers Included: Mineral

    Knowde Enhanced TDS

    Identification & Functionality

    Additives Included
    Fillers Included
    Plastics & Elastomers Functions
    Technologies

    Features & Benefits

    Materials Features
    Fire Resistance
    Halogen and antimony free

    Applications & Uses

    Properties

    Flame Rating
    Mechanical Properties
    ValueUnitsTest Method / Conditions
    Charpy Notched Impact Strength (at -20°C)2kJ/m2ISO 179-1/1eA
    Hardness65Shore DISO 868
    Charpy Notched Impact Strength (at 23°C)10kJ/m2ISO 179-1/1eA
    Charpy Unnotched Impact Strength (at -20°C)25kJ/m2ISO 179-1/1eU
    Charpy Unnotched Impact Strength (at 23°C)NBkJ/m2ISO 179-1/1eU
    Elongation at Break50%ISO 527-2/1A
    Flexural Modulus2450MPaISO 178
    Izod Notched Impact Strength11kJ/m2ISO 180/1A
    Stress at Break11MPaISO 527-2/1A
    Stress at Yield Point20MPaISO 527-2/1A
    Thermal Properties
    ValueUnitsTest Method / Conditions
    Heat Deflection Temperature70°CISO 75-2/Af
    Melting Point165/168°CISO 11357-3
    Vicat Softening Point145°CISO 306/A50
    Electrical Properties
    ValueUnitsTest Method / Conditions
    CTImin. 600VCEI 60112
    Surface Resistivitymin. 10^12Ω-squareCEI 60093
    Physico-Chemical Properties
    ValueUnitsTest Method / Conditions
    Density1.31g/cm3ISO 1183-1
    MVI (at 230°C-2.16Kg)5cm3/10minISO 1133-1
    Fire Resistance
    ValueUnitsTest Method / Conditions
    Falling Ball Test118°CCEI 60695-10-2
    Incandescent Glow Wire Flammability Test (2mm)960%CEI 60695-2-12
    Limit Oxygen Index27°CISO 4589-2
    Vertical Burning (at 1.6mm)V0Test 50W Ul94

    Regulatory & Compliance

    Certifications & Compliance

    Technical Details & Test Data

    Note
    • The LOI measures are obtained through standard specimens of type I, with ignition of type A.
    • The values indicated above have been realized with standard specimens which are conditionned according to ISO 291. These datas must be considered as indicative values, but in no case as minimum values. Moreover, the design of the mold/die, the processing conditions and the color may have an impact on the properties.