company tower banner
Addiplast Group Company Logo

Polymer Name: Polyamide 6/66 (PA 6/66)

    Knowde Enhanced TDS

    Identification & Functionality

    Chemical Family
    Technologies

    Applications & Uses

    Plastics & Elastomers End Uses

    Properties

    Mechanical Properties
    ValueUnitsTest Method / Conditions
    Charpy Notched Impact Strength (cond)15kJ/m2ISO 179-1/1eA
    Hardness83 / 76Shore DISO 7619-1
    Hardness (Cond)76Shore DISO 868
    Charpy Notched Impact Strength (dam)5kJ/m2ISO 179-1/1eA
    Strain at Break40 / min. 50%ISO 527
    Hardness (Dam)83Shore DISO 868
    Charpy Unnotched Impact Strength (cond)NBkJ/m2ISO 179-1/1eU
    Yield stress85 / 50MPaISO 527
    Charpy Unnotched Impact Strength (dam)NBkJ/m2ISO 179-1/1eU
    Flexural modulus, 23°2800 / 1000MPaISO 178
    Elongation at Break (cond)min. 50%ISO 527-2/1A
    Elongation at Break (dam)40%ISO 527-2/1A
    Flexural Modulus (cond)1000MPaISO 178
    Flexural Modulus (dam)2800MPaISO 178
    Charpy impact strength (+23°)N / NkJ/m2ISO 179/1eU
    Charpy notched impact strength (+23°)5.0/15.0kJ/m2ISO 179/1eA
    Izod Notched Impact Strength (cond)16kJ/m2ISO 180/1A
    Izod Notched Impact Strength (dam)5kJ/m2ISO 180/1A
    Stress at Yield Point (cond)50MPaISO 527-2/1A
    Stress at Yield Point (dam)85MPaISO 527-2/1A
    Physical Properties
    ValueUnitsTest Method / Conditions
    Density1140 / -kg/m3ISO 1183
    Thermal Properties
    ValueUnitsTest Method / Conditions
    Temperature of deflection under load (1.80 Mpa)65 / *°CISO 75-1/-2
    Melting temperature (10°C/min)243 / *°CISO 11357-1/-3
    Heat Deflection Temperature65°CISO 75-2/Af
    Melting Point243°CISO 11357-3
    Electrical Properties
    ValueUnitsTest Method / Conditions
    CTImin. 600VCEI 60112
    Physico-Chemical Properties
    ValueUnitsTest Method / Conditions
    Density1.14g/cm3ISO 1183-1
    Fire Resistance
    ValueUnitsTest Method / Conditions
    Incandescent Glow Wire Flammability Test (2mm)750°CCEI 60695-2-12
    Limit Oxygen Index23.2%ISO 4589-2

    Technical Details & Test Data

    Note
      The values indicated above have been realized with standard specimens in room temperature, except if particular conditions:
    • dam: specimens 48h after molding
    • cond: specimens conditioned according to ISO 291 et ISO 1110.
    • These datas must be considered as indicative values, but in no case as minimum values. Moreover, the design of the mold/die, the processing conditions and the color may have an impact on the properties. The information given herein is the outcome of our research and experience. It is given in all good faith but can neither be interpreted as a warranty given by us nor incur our liability especially in the event of infringement of third party rights.