company tower banner
Big Dog Adhesives Company Logo

RodLock® Structural Methacrylate Rodding Adhesive

1 of 1 products in this brand
RodLock® is a two-part non sag methacrylate, structural bonding adhesive designed for the structural bonding of steel and fiberglass rods into natural stone, granite, marble and porcelain counter top products. Combined at a ratio of 1:1, RodLock has a working time of 4 to 8 minutes and achieves nearly 90 percent of its ultimate strength in 10 to 15 minutes at room temperature curing. RodLock provides high strength bonds to the above reference surfaces with generally no preparation effort. RodLock bonds very strongly to steel, stainless steel, and aluminum metals. RodLock adhesives are not UV stable, and will yellow over time and must not be used to create imperceptible seams in countertops or for seaming countertops. This yellowing will not affect bond performance, but will affect bond appearance. Due to its high strength, keep groove widths and depths to a minimum, as wide and deep grooves may cause RodLock to crack the granite upon reacting and shrinking. We are not liable for cracked counter tops due to this effect.

Product Type: 2K (2 component) Adhesive, Seaming Adhesive

Compatible Substrates & Surfaces: Aluminum, Fiberglass, Marble, Metal, Stainless Steel, Steel, Stone

Chemical Family: Methacrylates

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Chemical Family

Features & Benefits

Chemical Resistance

Excellent Resistance to :

  • Hydrocarbons
  • Acids and Bases
  • Vinegar
  • Wine and Condiments
  • Most Household Foods


Susceptible to :

  • Polar Solvents
  • Super Strong Acids and Bases 

Applications & Uses

Applications

To assure maximum bond strength, surfaces must be mated together within the specified working time, and all clamps affixed within that time. Use sufficient material to ensure that the joint is completely filled when parts are mated and clamped. Avoid over clamping parts, which may cause a dry joint or a joint starved of adhesive. All adhesive application, part positioning, fixturing, and clamping should occur before the working time of the adhesive has expired. After the indicated working time, parts must remain undisturbed until the fixture time is completed. Components bonded, adhesive, and shop temperature can have a significant effect on the work and fixture time of the adhesive. Application of RodLock adhesive at temperatures between 65°F and 85°F (18°C and 30°C) will ensure proper cure. Temperatures below 65°F (18°C) will slow cure and fixture speed. RodLock adhesives will still react, but will take longer. Temperatures above 85°F (18°C and 30°C) will increase cure and fixture speeds, and there’s a risk that the adhesive will be hardened or too thick to bond materials. The viscosities of RodLock adhesives are affected by temperature.

Note : Because of the curing features of RodLock adhesives, large amounts of heat are generated when large masses of material are mixed at one time. The heat generated by the exotherm resulting from mixing large amounts of adhesive can result in a boiling of the monomer in the adhesive (methyl methacrylate), resulting in the release of trapped air, steam and volatile gasses. To prevent this, use only enough material as needed for use within the working time for the product, and confine the gap or spread out the material to no more than .50 inches.

Properties

Component A
ValueUnitsTest Method / Conditions
Viscosity (Uncured)80,000 - 180,000cps
Density (Uncured)8.2lbs/gal
Mix Ratio (wt or vol, Uncured)1
Mechanical Properties
ValueUnitsTest Method / Conditions
Tensile Strength (Fiberglass Surfaces)min. 2,500psiASTM D638
Tensile Strength (ABS/PVC Sheeting)min. 1,000psiASTM D638
Tensile Strength (Steel/Stainless Steel)2,500 - 3,500psiASTM D638
Tensile Strength (Aluminum)2,500 - 3,500psiASTM D638
Component B
ValueUnitsTest Method / Conditions
Viscosity (Uncured)80,000 - 180,000cps
Density (Uncured)8lbs/gal
Mix Ratio (wt or vol, Uncured)1
Cured Properties
ValueUnitsTest Method / Conditions
Working Time (at 75°F/ 24°C)4 - 8minutes
Fixture Time (at 75°F/ 24°C)10 - 15minutes
Can be Moved In (at Room Temperature)20minutes
Operating Temperature65 - 85 (18 - 30)°F (°C)
Gap Filling (at Room Temperature)0.375inches
Mixed Density (at Room Temperature)8.1 (0.96)lbs/gal (g/cc)
Flash Point (at Room Temperature)51 (11)°F (°C)
Uncured Physical Properties

Mixer Recommendation Cartridge (400ml) : MGQ 08-24T – Square 24 element, White/Clear Mix Tips (1:1)

Tensile Strength
Substrate Failure Type
Fiberglass Surfaces Substrate
ABS/PVC Sheeting Substrate
Steel/Stainless Steel Cohesive
Aluminum Cohesive

Regulatory & Compliance

Certifications & Compliance
Chemical Inventories

Safety & Health

Safety & Health Precautions

RodLock resin (Part A) and activator (Part B) are flammable. Contents include Methacrylate ester and acids. Keep containers closed after use. Wear gloves and safety glasses to avoid skin and eye contact. Wash with soap and water after skin contact. In case of eye contact, flush with water for 15 minutes and get medical attention. Harmful if swallowed. Keep out of the reach of children. Keep away from heat, sparks, and open flames. Do not smoke cigarettes or anything else while handling or near the product. Refer to the RodLock Safety Data Sheet for more complete safety instruction.

Storage & Handling

Shelf Life
12 Months
Storage, Handling and Shelf Life

The shelf life of RodLock is twelve (12) months from the date of manufacture based upon continuous storage at room temperature (77°F or 25°C). Storage of RodLock adhesives in refrigerated compartments will extend the shelf life even more. Do not store RodLock adhesive or any other adhesives in a refrigerator which has food or lunch products in them. Be sure to bring RodLock adhesives to room temperature for 24 hours before use, otherwise longer cure and fixture times may be expected. Long-term storage at temperatures above room temperature will shorten the shelf life of RodLock adhesives considerably. Storage at temperatures above 100°F or 38°C could shorten the shelf life to less than one month. RodLock adhesives contain no water, so freezing of the adhesive for short periods is permissible, but is not encouraged.